Viewing 1 to 30 of 74
Standard
2014-06-04
This SAE Standard covers hose intended for use with automatic transmission cooling system applications. Type A hoses are intended for original equipment or replacement applications while Type B hoses are intended for aftermarket auxiliary cooler applications only. The reference fluid for tests requiring the use of automatic transmission fluid (ATF) shall be Dexron III / Mercon 5 or equivalent ATF that is agreed to by hose manufacturer and customer.
Standard
2014-06-04
This SAE Standard outlines the requirements for a preformed thermosetting hose intended for use in heavy-duty vehicle engines, such as air cleaner to carburetor hose, where it is exposed to normal heat and splash of motor oil.
WIP Standard
2014-04-08
This SAE Standard covers reinforced and flexible hoses intended for use in water and ethylene glycol-based engine-coolant system applications.
WIP Standard
2014-04-02
This SAE Standard covers nonreinforced, extruded, flexible tubing intended primarily for use as fluid lines for automotive windshield washer systems which conform to the requirements of SAE J942.
WIP Standard
2014-04-02
The Measurement of Coolant Hose task group conducted a round-robin study to determine the measuring capability of automotive suppliers and users to measure Inside Diameter (ID), Outside Diameter (OD), Wall Thickness (Wall) and wall thickness variation of hose using traditional measuring devices and techniques. Seven companies (five suppliers and two end users) participated in this testing. Based upon the round-robin study this information report will detail procedures, test measuring devices, results and recommendations.
WIP Standard
2014-04-02
This SAE Recommended Practice is used for establishing the compression set that could be expected to occur with engine coolant hoses under securing clamps. It seeks to reproduce the type of indentation caused by the clamps in the wall of the hose. An excessive compression set measured by this method would indicate a hose that could eventually alloy leakage of coolant past the clamps in service. This method has been found to give repeatable results in the range of 25% to 50% initial compression.
WIP Standard
2014-04-02
The Hose Measurement Task Force conducted a round-robin study to determine the measuring capability of automotive suppliers and users to simultaneously measure the Inside Diameter (ID), Outside Diameter (OD), Wall Thickness (Wall), and Wall thickness Variation (WV) of hose using a laser-based, non-contact LOTIS QC-20 gauging device. Three (3) companies (all end users) participated in this testing with one of the three companies performing the GR&R calculations presented herein. Based upon the round-robin study this report will detail procedures, test measuring devices, results, and conclusions.
WIP Standard
2014-04-02
This SAE Standard covers reinforced hose, or hose assemblies, intended for conducting liquid and gaseous dichlorodifluoromethane (refrigerant 12) in automotive air-conditioning systems. The hose shall be designed to minimize permeation of refrigerant 12 and contamination of the system and to be serviceable over a temperature range of -30 to 120 °C (-22 to 248 °F). Specific construction details are to be agreed upon between user and supplier. NOTE— SAE J2064 is the Standard for refrigerant 134a hose. For refrigerant 134a use, refer to SAE J2064
Standard
2012-02-17
This SAE standard covers fuel, oil, or emission hose for use in coupled and uncoupled applications, for use with gasoline, oil, diesel fuel, lubrication oil, or the vapors present in either the fuel system or in the crankcase of internal combustion engines in mobile or stationary applications. This standard covers the hose portion only. If assembly / coupling is required, that is to be agreed to between the customer and assembler, along with the specific requirements.
Standard
2010-08-26
The purpose of this SAE Recommended Practice is to provide dimensions for both standard and thin-wall hoses and to provide commercial and precision tolerances for SAE 20R3 and SAE 20R4 coolant system hoses.
Standard
2010-06-16
The Gauge Evaluation Procedure Task Force was formed by the Non-Hydraulic Hose Committee to develop a gauge evaluation procedure to be used when evaluating the capability of gauges used for hose measurement. The use of a standard method for gauge evaluation will help users easily compare equipment capability. The information provided in this recommendation is based on the methods used to produce the data presented in SAE J1759 and J2605.
Standard
2010-02-15
This test method provides a standardized procedure for evaluating the electrical resistance of automotive coolant hose covers. It is know that an electrical potential exists between the engine and the radiator. Coolant hose cover conductivity has been determined to be a factor in reduced hose clamp life when vehicle build variations allow possible contact of the hose or the clamp to contact metal components on the radiator and engine thus completing an electrical circuit. The ensuing electrical current can undercut the clamp protective coating, leaving it vulnerable to the corrosive effects of road salts, moisture, and other environmental contaminants. SAE Recommended Practice J1684 addresses the conductivity of the tube portion of the coolant hose.
Standard
2009-06-04
This SAE Standard provides ordering information for any SAE 20R5 hose type (such as "EC, HT, LT" or combination thereof.) This is a wire-reinforced hose for coolant circulating systems of automotive type engines. This hose consists of a convoluted section with plain ends. The hose shall contain a wire helix or helices in the convoluted section. It is a supplement for Government use but may be used by others.
Standard
2009-06-04
This SAE Standard provides ordering information for any SAE 20R1 through SAE 20R4 hose type (such as EC, HT, LT, or combination thereof.) It is a supplement for Government use but may be used by others.
Standard
2009-03-05
To provide the curved hose industry and their customers with a recommended practice for applying GD&T procedures to curved hoses and to provide generic curved hose drawings that represent the application of GD&T to typical curved hose parts. Dimensioning and Tolerancing will be in accordance with ASME Y14.5M.
Standard
2008-12-23
This SAE standard covers fuel, oil, or emission hose for use in coupled and uncoupled applications, for use with gasoline, oil, diesel fuel, lubrication oil, or the vapors present in either the fuel system or in the crankcase of internal combustion engines in mobile or stationary applications. This standard covers the hose portion only. If assembly / coupling is required, that is to be agreed to between the customer and assembler, along with the specific requirements.
Standard
2007-07-02
This SAE Standard covers the minimum requirements for a low-permeation tubing (100 g/m2 day or less) for use as a low pressure (14.5 kPa) liquid- or vapor-carrying component for use in gasoline or diesel fuel filler, vent, and vapor systems. The construction shall be designed to be functional over a temperature range of --40 C to 100 C for the T1 designation, or --40 C to 125 C for the T2 designation.
Standard
2007-06-15
This test method provides a standardized procedure for evaluating the electrical resistance of automotive coolant hose covers. It is know that an electrical potential exists between the engine and the radiator. Coolant hose cover conductivity has been determined to be a factor in reduced hose clamp life when vehicle build variations allow possible contact of the hose or the clamp to contact metal components on the radiator and engine thus completing an electrical circuit. The ensuing electrical current can undercut the clamp protective coating, leaving it vulnerable to the corrosive effects of road salts, moisture, and other environmental contaminants. SAE Recommended Practice J1684 addresses the conductivity of the tube portion of the coolant hose.
Standard
2006-06-19
This SAE Standard covers reinforced and flexible hoses intended for use in water and ethylene glycol-based engine-coolant system applications.
Standard
2006-03-03
This SAE Standard covers nonreinforced, extruded, flexible tubing intended primarily for use as fluid lines for automotive windshield washer systems which conform to the requirements of SAE J942.
Standard
2006-01-04
The Measurement of Coolant Hose task group conducted a round-robin study to determine the measuring capability of automotive suppliers and users to measure Inside Diameter (ID), Outside Diameter (OD), Wall Thickness (Wall) and wall thickness variation of hose using traditional measuring devices and techniques. Seven companies (five suppliers and two end users) participated in this testing. Based upon the round-robin study this information report will detail procedures, test measuring devices, results and recommendations.
Standard
2006-01-04
The Hose Measurement Task Force conducted a round-robin study to determine the measuring capability of automotive suppliers and users to simultaneously measure the Inside Diameter (ID), Outside Diameter (OD), Wall Thickness (Wall), and Wall thickness Variation (WV) of hose using a laser-based, non-contact LOTIS QC-20 gauging device. Three (3) companies (all end users) participated in this testing with one of the three companies performing the GR&R calculations presented herein. Based upon the round-robin study this report will detail procedures, test measuring devices, results, and conclusions.
Standard
2005-09-12
This SAE Standard outlines the requirements for a preformed thermosetting hose intended for use in heavy-duty vehicle engines, such as air cleaner to carburetor hose, where it is exposed to normal heat and splash of motor oil.
Standard
2005-09-12
This test method provides a standardized procedure for evaluating the electrochemical resistance of automotive coolant hose and materials. Electrochemical degradation has been determined to be a major cause of EPDM coolant system hose failures. The test method consists of a procedure which induces voltage to a test specimen while it is exposed to a water/coolant solution. Method #1, referred to as a "Brabolyzer" test, is a whole hose test. Method #2, referred to as a "U" tube test, uses cured plate samples or plates prepared from tube material removed from hose (Method No. 2 is intended as a screening test only). Any test parameters other than those specified in this SAE Recommended Practice, are to be agreed to by the tester and the requester.
Standard
2005-03-07
This SAE Standard covers four types of hose for use with automatic transmission fluid: A, B, AT, and BT. Type A and Type B are for use within a temperature range of -40 to 125 degrees C (-40 to 257 degrees F) while types AT and BT are for use within a temperature range of -40 to 150 degrees C (-40 to 302 degrees F). Recommended maximum operating pressure for Type A and Type AT hose is 1.7 MPa (250 psi) while recommended maximum operating pressure for Type B and Type BT hose is 1.0 MPa (150 psi). The lower pressure (Types B and BT) hose is for auxiliary cooler applications only. The reference fluid for tests requiring the use of automatic transmission fluid shall be Dexron-II E/Mercon or equivalent.
Standard
2004-11-30
This SAE Recommended Practice is used for establishing the compression set that could be expected to occur with engine coolant hoses under securing clamps. It seeks to reproduce the type of indentation caused by the clamps in the wall of the hose. An excessive compression set measured by this method would indicate a hose that could eventually alloy leakage of coolant past the clamps in service. This method has been found to give repeatable results in the range of 25% to 50% initial compression.
Standard
2004-06-14
This SAE Standard covers reinforced hose, or hose assemblies, intended for conducting liquid and gaseous dichlorodifluoromethane (refrigerant 12) in automotive air-conditioning systems. The hose shall be designed to minimize permeation of refrigerant 12 and contamination of the system and to be serviceable over a temperature range of -30 to 120 °C (-22 to 248 °F). Specific construction details are to be agreed upon between user and supplier. NOTE— SAE J2064 is the Standard for refrigerant 134a hose. For refrigerant 134a use, refer to SAE J2064
Standard
2004-05-10
This SAE Standard covers reinforced and flexible hoses intended for use in water and ethylene glycol-based engine-coolant system applications.
Standard
2003-12-19
To provide the curved hose industry and their customers with a recommended practice for applying GD&T procedures to curved hoses and to provide generic curved hose drawings that represent the application of GD&T to typical curved hose parts. Dimensioning and Tolerancing will be in accordance with ASME Y14.5M.
Standard
2003-11-04
The Gauge Evaluation Procedure Task Force was formed by the Non-Hydraulic Hose Committee to develop a gauge evaluation procedure to be used when evaluating the capability of gauges used for hose measurement. The use of a standard method for gauge evaluation will help users easily compare equipment capability. The information provided in this recommendation is based on the methods used to produce the data presented in SAE J1759 and J2605.