Pulse Power Testing of Batteries and Supercapacitors for Hybrid Electric Vehicle Applications: A Comparison of Constant Current, Constant Power, and Ramped Power Transients

2013-04-08
2013-01-1535
The central performance requirement for electrochemical energy storage systems for the full power-assist hybrid electric vehicle (HEV) is pulse power capability, typically 25-40 kW pulse power capability for 10 seconds duration. Standard test procedures utilize constant current pulses. However, in the HEV application, the power transient for acceleration is a ramped power transient and the power transient for regenerative braking power is a descending power ramp. This paper compares the usable power capability of batteries and supercapacitors under constant current, constant power, and ramped power transients. Although the usable battery discharge power is relatively insensitive to the transient type applied, 10-40% higher regenerative braking charge capability is observed with ramped power transients. With supercapacitors, the discharge and charge capability is much more strongly dependent on the type of power transient.