Standard

Circuit Breakers

2022-05-26
CURRENT
J553_202205
This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 200 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 VDC, 24 VDC, and 48 VDC electrical systems. Some circuit breakers may have dual voltage ratings (AC and DC); however, this document evaluates DC performance only.
Standard

Cable Marking for Circuit Identification in Multi-Voltage Power Distribution Systems

2021-01-13
CURRENT
J3176_202101
This SAE Standard establishes the minimum circuit identification and requirements for Multi-Voltage Power Distribution Systems (MVPDS) for use on trucks and buses. A Multi-Voltage Power Distribution System is one that distributes two or three voltages, up to 60 VDC, to power the controls, instruments, and devices.
Standard

Coiled Electrical Cable - Truck and Bus

2020-02-25
CURRENT
J2222_202002
This SAE Standard establishes the minimum performance and endurance requirements for coiled electrical cables used for hookup between trucks, trailers, and dollies for 12 VDC nominal applications. The component standards SAE J2394 (replaced SAE J1067) for cable and SAE J560 for connectors must be consulted to determine the complete performance and endurance requirements of the system. Related TMC Recommended Practices may be consulted for information associated with selection, installation, and inspection of these coiled electrical cables. This document is intended to set out requirements for the majority of conditions rather than for specialized applications or environments.
Standard

Combination 11 Conductors and Two Pairs ECBS Cable

2020-02-24
CURRENT
J2742_202002
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and two twisted pairs for use on trucks, trailers, and dollies for 12 VDC nominal applications in conjunction with SAE J2691 (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Heavy Duty High Speed Datalink Connector

2020-01-08
CURRENT
J2839_202001
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Combination 11 Conductors and 2 Pairs ECBS Cable

2018-06-03
HISTORICAL
J2742_201806
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and 2 twisted pairs for use on trucks, trailers, and dollies in conjunction with SAE J2691. (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2018-04-15
HISTORICAL
J2691_201804
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Coiled Electrical Cable - Truck and Bus

2018-02-15
HISTORICAL
J2222_201802
This SAE Standard establishes the minimum performance and endurance requirements for coiled electrical cables used for hookup between trucks, trailers and dollies. The component standards SAE J2394 (replaced SAE J1067) for cable and SAE J560 for connectors must be consulted to determine the complete performance and endurance requirements of the system. Related TMC Recommended Practices may be consulted for information associated with selection, installation and inspection of these coiled electrical cables. This document is intended to set out requirements for the majority of conditions rather than for specialized applications or environments.
Standard

Seven Conductor Cable for ABS Power - Truck and Bus

2017-12-20
HISTORICAL
J2394_201712
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-2/10-4/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications. While the document’s title refers to ABS Power to differentiate the document from the SAE J1067 standard that it supersedes, the scope applies to both the primary green cable for powering ABS and lighting and the yellow auxiliary cable of the same construction.
Standard

Seven Conductor Cable - Truck and Bus

2016-10-25
HISTORICAL
J1067_201610
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-1/10-5/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Heavy Duty High Speed Datalink Connector

2015-07-08
HISTORICAL
J2839_201507
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Heavy-Duty Circuit Breakers

2013-05-03
CURRENT
J1625_201305
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for circuit breakers in ratings from 50 to 200 A. The document covers externally mounted automatic reset and manually reset types of circuit breakers for low voltage DC operation (typically 50 V or less).
Standard

Combination 11 Conductors and 4 Pairs ECBS Cable

2013-04-09
HISTORICAL
J2742_201304
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and 4 twisted pairs for use on trucks, trailers, and dollies in conjunction with SAEJ2691. (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2013-04-09
HISTORICAL
J2691_201304
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742 “Combination 11 Conductors and 4 Pairs ECBS Cable”. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Seven Conductor Cable for ABS Power - Truck and Bus

2013-02-01
HISTORICAL
J2394_201302
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-2/10-4/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications. While the document’s title refers to ABS Power to differentiate the document from the SAE J1067 standard that it supersedes, the scope applies to both the primary green cable for powering ABS and lighting and the yellow auxiliary cable of the same construction.
Standard

Coiled Electrical Cable - Truck and Bus

2012-10-24
HISTORICAL
J2222_201210
This SAE Standard establishes the minimum performance and endurance requirements for coiled electrical cables used for hookup between trucks, trailers and dollies. The component standards SAE J2394 (replaced SAE J1067) for cable and SAE J560 for connectors must be consulted to determine the complete performance and endurance requirements of the system. Related TMC Recommended Practices may be consulted for information associated with selection, installation and inspection of these coiled electrical cables. This document is intended to set out requirements for the majority of conditions rather than for specialized applications or environments.