Standard

Combination 11 Conductors and Two Pairs ECBS Cable

2020-02-24
J2742_202002
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and two twisted pairs for use on trucks, trailers, and dollies for 12 VDC nominal applications in conjunction with SAE J2691 (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Combination 11 Conductors and 2 Pairs ECBS Cable

2018-06-03
J2742_201806
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and 2 twisted pairs for use on trucks, trailers, and dollies in conjunction with SAE J2691. (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Combination 11 Conductors and 4 Pairs ECBS Cable

2013-04-09
J2742_201304
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and 4 twisted pairs for use on trucks, trailers, and dollies in conjunction with SAEJ2691. (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2020-02-25
J2691_202002
This SAE Standard establishes the minimum construction and performance requirements for a 15 pole connector between towing vehicles and trailers, for trucks, trailers, and dollies, for 12 VDC nominal applications in conjunction with SAE J2742. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2018-04-15
J2691_201804
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2013-04-09
J2691_201304
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742 “Combination 11 Conductors and 4 Pairs ECBS Cable”. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

VOLTAGE DROP FOR STARTING MOTOR CIRCUITS

1996-10-01
J541_199610
The scope of this SAE Recommended Practice is to describe the maximum recommended voltage drop for starting motor circuits for 6 V through 32 V starters.
Standard

Voltage Drop for Starting Motor Circuits

2013-07-16
J541_201307
The scope of this SAE Recommended Practice is to describe the maximum recommended voltage drop for starting mortor circuits for 6 V through 32 V starters.
Standard

HEAVY-DUTY CIRCUIT BREAKERS

1996-04-01
J1625_199604
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for circuit breakers in ratings from 50 to 200 A. The document covers externally mounted automatic reset and manually reset types of circuit breakers for low voltage DC operation (typically 50 V or less).
Standard

Positive Temperature Coefficient Overcurrent Protection Devices (PTCs)

2006-05-18
J2685_200605
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for PTC (positive temperature coefficient of resistance) overcurrent protection devices. PTCs are typically either polymeric (PPTC) or ceramic (CPTC). It is important to note battery voltages versus powernets/system voltage versus max battery voltages: (12 V/14 V/16 V, 24 V/28 V/32 V, and 36 V/42 V/58 V). All voltages are DC. These devices are typically rated with a maximum operating voltage, which for vehicular systems need to be 16 V (for 12 V batteries), 32 V (for 24 V batteries), and 58 V (for 36 V batteries/42 V powernets). PTC devices are considered to be self-resetting after responding to overcurrent conditions and after such condition has been removed from the affected circuit containing the PTC.
Standard

Heavy Duty High Speed Datalink Connector

2020-01-08
J2839_202001
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Heavy Duty High Speed Datalink Connector

2010-02-18
J2839_201002
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Heavy Duty High Speed Datalink Connector

2015-07-08
J2839_201507
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

COILED ELECTRICAL CABLE

1993-11-01
J2222_199311
This Draft Technical Report covers the minimum performance and endurance requirements for coiled electrical cables to connect a tractor and trailer and/or trailer to trailer. The purpose of this Draft Technical Report is to give the technical community the opportunity to review, comment on, and use the Draft Technical Report prior to its final approval by SAE. This document shall have a life span of no more than three years from approval which may not be renewed. This Draft Technical Report represents the current thinking of the sponsoring Technical Committee. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringements arising therefrom, is the sole responsibility of the user. Comments on this Draft are welcome and should be submitted in writing to Secretary, Technical Standards Board, SAE Headquarters, 400 Commonwealth Drive, Warrendale, PA 15096-0001.