This Aerospace Recommended Practice (ARP) describes test equipment and methods used for testing closed cycle or semi closed cycle breathing devices of short duration that are designed to operate with a high partial pressure of oxygen in the breathing circuit. It is intended to supplement ARP1109 and ARP1398 for applications involving closed cycle or semiclosed cycle breathing equipment which may be evaluated to the requirements of AS8031 and/or AS8047.
The purpose of this document is to provide minimum requirements for cleaning aircraft breathing oxygen systems and components, inspection methods and packaging after cleaning, and guidelines for oxygen equipment cleaning areas.
This document covers information concerning the use of oxygen when flying into and out of high elevation airports for both pressurized and non-pressurized aircraft. Oxygen requirements for pressurized aircraft operating at high altitudes have for decades emphasized the potential failures that could lead to a loss of cabin pressurization coupled with the potential severe hypoxic hazard that decompressions represent. This document is intended to address the case where the relationship between cabin and ambient pressures are complicated by operations at high terrestrial altitudes. Operators who fly into these high-altitude airports should address the issues related to this environment because it carries the potential for insidious hypoxia and other conditions which can affect safety. It provides information to consider in developing operational procedures to address hypoxia concerns consistent with regulatory mandates.
Solid chemical oxygen supplies of interest to aircraft operations are "chlorate candles" and potassium superoxide (KO2). Chlorate candles are used in passenger oxygen supply units and other emergency oxygen systems, such as submarines and escape devices. Potassium superoxide is not used in aircraft operations but is used in closed-cycle breathing apparatus. Characteristics and applications of both are discussed, with emphasis on chlorate candles.
Solid chemical oxygen supplies of interest to aircraft operations are "chlorate candles" and potassium superoxide (KO2). Chlorate candles are used in passenger oxygen supply units and other emergency oxygen systems, such as submarines and escape devices. Potassium superoxide is not used in aircraft operations but is used in closed-cycle breathing apparatus. Characteristics and applications of both are discussed, with emphasis on chlorate candles.
This standard is designed to cover all types of pressure reducers required for oxygen systems and for all performance profiles without regard for a particular inlet pressure or outlet pressure performance curve. Special attention will be given, however, to construction requirements essential in reducers where critical high initial oxygen pressures such as 1850 to 2250 psig (12.76 to 15.51 MN/m2 gauge) at 70° F (21.1° C) are involved.
This specification applies to a chemical oxygen generator assembly for the following uses: a First aid treatment of passenger cabin occupants after emergency descent in a turbine engine powered airplane with pressurized cabin, as specified in FAR 121.333, Para. e (3). b By cabin attendants to maintain their mobility after cabin decompression.
This SAE Aerospace Standard (AS) applies to a portable chemical oxygen generator assembly intended for the following uses: a First aid treatment of aircraft occupants after an emergency descent following a decompression or other emergency condition. b Use by cabin attendants to maintain their mobility after a decompression.
This SAE Aerospace Standard (AS) applies to a portable chemical oxygen generator assembly intended for the following uses: a First aid treatment of aircraft occupants after an emergency descent following a decompression or other emergency condition. b Use by cabin attendants to maintain their mobility after a decompression.
This document provides information on provisions for passengers with disabilities on board commercial aircraft. In this context the term "provision of medical oxygen" shall be understood as application of oxygen on board an aircraft not linked to (post) decompression in the sense of Airworthiness Requirements FAR/CS 25 and Operational Regulations of FAR 121/135. Information about available equipment and physiological treatment in clinical practice will be provided in this document. It covers the use of oxygen concentrators according to guidance of FAR Advisory Circular AC120-95.
This SAE Aerospace Information Report (AIR) provides a general overview of oxygen systems for general aviation use. Included are a brief review of the factors and effects of hypoxia, system descriptions, and mission explanations for system or component selection, and techniques for safe handling of oxygen distribution systems.