Criteria

Text:
Display:

Results

Viewing 1 to 30 of 184
2014-01-29
WIP Standard
AIR825/13A
This guide is intended to promote safe designs, operations and maintenance on aircraft and ground support oxygen systems. This is also a summary of some work by the ASTM G 4 Committee related to oxygen fire investigations and design concerns to reduce the risk of an oxygen fire. There have been many recent technological advances and additional test data is available for evaluating and controlling combustion hazards in oxygen equipment. Standards that use this new information are rapidly evolving. A guide is needed to assist organizations and persons not completely familiar with this process to provide oxygen systems with minimum risks of combustion. This guide does not necessarily address all the detailed issues and provide all data that will be needed. For a complete analysis, supplemental publications need to be consulted. This guide does discuss the basics of oxygen systems fire hazards. The hazard analysis process is discussed and a simple example to explain this process.
2014-10-23
WIP Standard
AIR5933
This AIR5933 gives an overview of contemporary technologies to determine the oxygen concentration respectively partial pressure in air. The aerospace application and its special constraints have been emphasized regarding weight, power supply, overall size, reliability and safety, cost and useful life.
2015-09-22
WIP Standard
AIR6256
The aim of this document is to provide a comprehensive synopsis of regulations applicable to aircraft oxygen systems. The context of physiological requirements, international regulations, operational requirements and airworthiness standards is shown to understand the role of aircraft oxygen systems and to demonstrate under which circumstances is needed on aircraft. With regards to National Aviation Regulations States are committed to the Convention on International Aviation (Chicago Convention). The majority of states have adopted, with some deviations, FAA and EASA systems including operational and airworthiness requirements. Accordingly the extent of this document is primarily focused on FAA/EASA requirements.
2013-03-07
WIP Standard
ARP6244
This document describes technical approaches that can be applied to show that proposed oxygen equipment and systems achieve suitable oxygenation in users. These approaches can be used to demonstrate that items under test meet performance criteria sufficient to justify certification for use in aircraft applications.
2015-11-30
WIP Standard
ARP6527
The scope of this document is to provide guidance concerning the use of oxygen when flying into and out of high elevation airports. Normally for aircraft operations that fly at high altitude, oxygen requirements involving a decompression are generally easy to understand and follow because of the increased delta between cabin and ambient pressures. This document is intended to address a transition zone where cabin and ambient pressures are closely the same and oxygen usage can be compounded by physiologic subjectivity that often accompanies hypoxia. This transition zone is further diluted by regulations which are based not on science but rather sociological mores often not supported by empirical science. An example of this is reflected by differential regulatory requirements between CFR’s 91, 121 and 135. Operators who fly into these high altitude airports will undoubtedly be required to address the inherent threats and errors associated with this transition zone.
2016-03-09
WIP Standard
ARP5021B
This document provides guidance for oxygen cylinder installation on commercial aircraft based on rules and methods practiced in aerospace industry and applicable in other associations. It covers considerations for oxygen systems from beginning of project phase up to production, maintenance, and servicing. The document is focused on requirements regarding DOT approved oxygen cylinders. However, its basic rules may also be applicable to new development pertaining to use of such equipment in an oxygen environment. For information regarding oxygen cylinders itself, reference should be made to AIR825/12 also.
2014-05-08
WIP Standard
ARP5932
This SAE Aerospace Recommended Practice (ARP) will provide general guidelines and procedures for servicing and maintaining oxygen systems. Such methods and procedures may be applied to gaseous, liquid, chemical and portable oxygen systems. These guidelines and recommendations will be provided to engineering and maintenance personnel for airlines, modification centers and third party maintenance contractors, to be used while performing maintenance on oxygen systems and components.
2016-03-08
WIP Standard
AS916C
This SAE Aerospace Standard (AS) defines the overall requirements applicable to oxygen flow indicating devices intended to operate in conjunction with an oxygen regulator and mask system. Flow indicators covered by this document are for use with pressure demand, diluter-demand and continuous flow oxygen systems.
2015-12-07
WIP Standard
AS6371
This Aerospace Standard will provide the basis for a certification approach and contain the methods or criteria for verification of performance required for Oxygen Dispensing Units to be used by Cabin Crew up to 25,000 ft. cabin altitude.
2007-03-26
WIP Standard
AS5722
This Aerospace Standard will provide the basis for a certification approach and contain the methods or criteria for verification of performance required of Personal Oxygen Dispensing Units for use by Cockpit Crew Members in the range of 35,000 to 45,000 ft cabin altitude.
2013-02-25
WIP Standard
AS5727
This Aerospace Standard (AS5727) will provide the basis for a certification approach and contain the methods or criteria for verification of performance required of Oxygen Dispensing Units for use by cabin occupants in the range of 40,000 to 45,000 ft. cabin altittude. 1.1 Purpose - This AS is intended to identify the performance required of Personal Oxygen Dispensing Units in the range of 40,000 to 45,000 ft.
2013-06-14
WIP Standard
AIR825/1A
The purpose of this document is to give the reader an overview of the document package which makes up AIR825, Introduction to Oxygen Equipment for Aircraft, and a basic overview (see Section 4) of the operational concerns driven by human physiology during altitude exposure.
2015-10-05
WIP Standard
AS8047A
This aerospace standard (AS) defines the requirements of portable protective breathing equipment for use during smoke/fire conditions on board an aircraft.
2009-04-16
WIP Standard
AS8031B
This SAE Aerospace Standard (AS) covers any protection system that serves the stated purpose. This document establishes minimum performance requirements for emergency equipment, which provides flight deck (sedentary) crewmembers with eye and respiratory protection from toxic atmospheres during in-flight emergencies. Defintion of sedentary: "sedentary" is herein defined as those flight deck crewmembers that remain seated at their flight deck stations throughout the emergency. For those "nonsedentary" cabin crewmembers whose duty it is to leave their flight station during an emergency (for example, to actively locate and fight an on-board fire).
CURRENT
2016-08-01
Standard
ARP6390
Various emergency situations may require the dispensing of oxygen to all occupants of aircraft during flight. During an emergency event, depending on the aircraft operational flight capability, all cabin occupants must be serviced by a mask presentation system connected to an operational oxygen source. Several regulations specify the functional characteristics and requirements of the oxygen systems for aircraft in support of different missions. These should be referred to for the exact functional performance requirements. It is not the intent of this document to ensure conformance with these regulations, but only to recommend general concepts for the location of the oxygen masks and oxygen system outlets for proper accessibility by the aircraft occupants, whether cabin occupants or crew members. Different requirements may apply when the mission of the pressurized aircraft or the operational altitude of the aircraft is not in excess of FL250.
CURRENT
1996-07-01
Standard
ARP4259A
This Aerospace Recommended Practice (ARP) describes test equipment and methods used for testing closed cycle or semiclosed cycle breathing devices of short duration that are designed to operate with a high partial pressure of oxygen in the breathing circuit. It is intended to supplement ARP1109 and ARP1398 for applications involving closed cycle or semiclosed cycle breathing equipment which may be evaluated to the requirements of AS8031 and/or AS8047.
CURRENT
2011-06-01
Standard
ARP5021A
This document provides guidance for oxygen cylinder installation on commercial aircraft based on rules and methods practiced in aerospace industry and applicable in other associations. It covers considerations for oxygen systems from beginning of project phase up to production, maintenance, and servicing. The document is focused on requirements regarding DOT approved oxygen cylinders. However, its basic rules may also be applicable to new development pertaining to use of such equipment in an oxygen environment. For information regarding oxygen cylinders itself, reference should be made to AIR825/12 also.
CURRENT
1996-07-01
Standard
AS1224B
This standard defines the minimum requirement for the design, construction and performance of continuous flow oxygen masks for crew and passengers of general aviation civil aircraft.
CURRENT
2005-02-14
Standard
AS1219A
This SAE Aerospace Design Standard defines a coupling, which is installed in a high pressure (1850 to 2000 psig) oxygen system of a civil transport aircraft for the purpose of mating to ground oxygen replenishment facilities. Dimensions developed from AND10089, Detail Specification Sheet for Fitting End, Design Standard, For Cone Connection.
CURRENT
2005-02-16
Standard
AS1214B
This SAE AEROSPACE Standard (AS) covers all types of manually operated high pressure Oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft.
CURRENT
2011-06-20
Standard
AS1065A
This specification covers the servicing of gaseous oxygen cylinders used for breathing purposes in civil aircraft. (Refer to AIR 1059 on Transfilling & Maintenance of Oxygen Cylinders.)
CURRENT
1987-11-01
Standard
AS8047
This aerospace standard (AS) defines the requirements of portable protective breathing equipment for use during smoke/fire conditions on board an aircraft.
CURRENT
2008-09-22
Standard
AS8048
This SAE Aerospace Standard (AS) defines the performance requirements for equipment to be used by untrained cabin occupants for protection from toxic and irritant atmospheres while on board and during evacuation of an aircraft.
CURRENT
1999-03-01
Standard
AS8031A
This SAE Aerospace Standard (AS) covers any protective system that serves the stated purpose.
CURRENT
1999-01-01
Standard
AS8025A
This standard covers oronasal type masks which use a continuous flow oxygen supply. Each such mask comprises a facepiece with valves as required, a mask suspension device, a reservoir, or rebreather bag (when used), a length of tubing for connection to the oxygen supply source, and a means for allowing the crew to determine if oxygen is being delivered to the mask. The assembly shall be capable of being stowed suitably to meet the requirements of its intended use.
CURRENT
2006-11-07
Standard
AS861B
This standard covers all types of oxygen breathing equipment used in non-military aircraft. It is intended that this standard supplement the requirements of the detail specification or drawings of specific components or assemblies, e.g., regulators, masks, cylinders, etc. Where a conflict exists between this and detail specifications, detail specifications shall take precedence.
CURRENT
1996-07-01
Standard
AS916B
This SAE Aerospace Standard (AS) defines the overall requirements applicable to oxygen flow indicating devices intended to operate in conjunction with an oxygen regulator and mask system. Flow indicators covered by this document are for use with pressure demand, diluter-demand and continuous flow oxygen systems.
CURRENT
2012-10-15
Standard
ARP1320B
This ARP covers a procedure to be used in the determination of 0.05 to 0.3 ppm of chlorine in oxygen from any type of generator used for emergency or other life-support systems. The methyl orange method described can be considered as a referee technique. Instrumental analysis is also given in Section 8.
HISTORICAL
1999-03-01
Standard
AIR1223A
CURRENT
2014-12-31
Standard
AIR1358C
This Aerospace Information Report (AIR) indicates those dimensions, deemed critical by the manufacturer to assure proper mating of disconnect hose fittings. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Viewing 1 to 30 of 184