Refine Your Search

Search Results

Viewing 1 to 10 of 10
Journal Article

Energy Efficient HVAC System with Spot Cooling in an Automobile - Design and CFD Analysis

2012-04-16
2012-01-0641
Spot, or distributed, cooling and heating is an energy efficient way of delivering comfort to an occupant in the car. This paper describes an approach to distributed cooling in the vehicle. A two passenger CFD model of an SUV cabin was developed to obtain the solar and convective thermal loads on the vehicle, characterize the interior thermal environment and accurately evaluate the fluid-thermal environment around the occupants. The present paper focuses on the design and CFD analysis of the energy efficient HVAC system with spot cooling. The CFD model was validated with wind tunnel data for its overall accuracy. A baseline system with conventional HVAC air was first analyzed at mid and high ambient conditions. The airflow and cooling delivered to the driver and the passenger was calculated. Subsequently, spot cooling was analyzed in conjunction with a much lower conventional HVAC airflow.
Technical Paper

CFD-Aided Development of Spray for an Outwardly Opening Direct Injection Gasoline Injector

1998-02-23
980493
A high pressure outwardly opening fuel injector has been developed to produce sprays that meet the stringent requirements of gasoline direct injection (DI) combustion systems. Predictions of spray characteristics have been made using KIVA-3 in conjunction with Star-CD injector flow modeling. After some modeling iterations, the nozzle design has been optimized for the required flow, injector performance, and spray characteristics. The hardware test results of flow and spray have confirmed the numerical modeling accuracy and the spray quality. The spray's average Sauter mean diameter (SMD) is less than 15 microns at 30 mm distance from the nozzle. The DV90, defined as the drop diameter such that 90% of the total liquid volume is in drops of smaller diameter, is less than 40 microns. The maximum penetration is about 70 mm into air at atmospheric pressure. An initial spray slug is not created due to the absence of a sac volume.
Technical Paper

Determining Hearing Threshold of Interior Noise Using Adaptive Procedure

2001-04-30
2001-01-1574
A jury evaluation study has been conducted to determine the hearing threshold of IP gauge stepping motor noise using a transformed up-down procedure. The stepping motor noise was recorded in an anechoic chamber and was used as a signal in the study. To determine the masked threshold, this signal was adjusted to various gain levels and mixed with interior engine noise at selected rpm as masking noise. In this study, the Adaptive Procedure was used, and a software application was developed for this purpose. Twenty subjects, selected based on hearing test results, participated in this jury evaluation. The findings of this study indicated that Adaptive Procedure is an effective approach in determining hearing threshold for automotive applications. A design criterion for acoustical characteristics of the IP gauge DC motor noise has been developed based on the results of this study.
Technical Paper

Analysis of a Planar Solid Oxide Fuel Cell Based Automotive Auxiliary Power Unit

2002-03-04
2002-01-0413
The solid oxide fuel cell (SOFC) system has emerged as an important technology for automotive and stationary applications. Modeling and simulation of the SOFC system have been utilized as an integral tool in an accelerated joint SOFC system development program. Development of unique modeling approaches and their results are discussed and compared with experimental performance. One dimensional system level analysis using Aspen with an embedded stack electrochemical model was performed resulting in effective sub-system partitioning and requirements definition. Further, a three-dimensional integrated electrochemical / thermal / computational fluid dynamics analysis of steady-state operation was employed. The combination of one-dimensional and three-dimensional environments led to effective performance projection at all levels in the system, resulting in optimization of overall system performance early in the design cycle.
Technical Paper

Transient Simulation of DGI Engine Injector with Needle Movement

2002-10-21
2002-01-2663
Utilization of direct injection systems is one of the most promising technologies for fuel economy improvement for SI engine powered passenger cars. Engine performance is essentially influenced by the characteristics of the injection equipment. This paper will present CFD analyses of a swirl type GDI injector carried out with the Multiphase Module of AVL's FIRE/SWIFT CFD code. The simulations considered three phases (liquid fuel, fuel vapor, air) and mesh movement. Thus the transient behavior of the injector can be observed. The flow phenomena known from measurement and shown by previous simulation work [2, 7, 10, 11] were reproduced. In particular the simulations shown in this paper could explain the cause for the outstanding atomization characteristics of the swirl type injector, which are caused by cavitation in the nozzle hole.
Technical Paper

Thermal Comfort Prediction and Validation in a Realistic Vehicle Thermal Environment

2012-04-16
2012-01-0645
The focus of this study is to validate the predictive capability of a recently developed physiology based thermal comfort modeling tool in a realistic thermal environment of a vehicle passenger compartment. Human subject test data for thermal sensation and comfort was obtained in a climatic wind tunnel for a cross-over vehicle in a relatively warm thermal environment including solar load. A CFD/thermal model that simulates the vehicle operating conditions in the tunnel, is used to provide the necessary inputs required by the stand-alone thermal comfort tool. Comparison of the local and the overall thermal sensation and comfort levels between the human subject test and the tool's predictions shows a reasonably good agreement. The next step is to use this modeling technique in designing and developing energy-efficient HVAC systems without compromising thermal comfort of the vehicle occupants.
Technical Paper

USE OF CFD SIMULATION TO PREDICT CAVITATION IN AUTOMOTIVE HEATER CORES

2005-11-22
2005-01-4027
Several heater cores failed due to erosion by cavitation. After analysis, most of failures were explained by the presence of impurities in the heater core. It was then decided with the customer to use CFD simulation in order to prove that the cavitation was not caused by design concept of the tank. In this paper, we present the results of heater core simulations done in 2D and in 3D with Fluent. The objective is to simulate the pressure and velocity distribution within the heater core and to verify if the zones of low pressure are below the saturation vapour pressure of the fluid causing cavitation. In these areas, the deterioration of the tubes might occur due to erosion by cavitation.
Technical Paper

Use of CFD Simulation to Predict Fan Power and Airflow Pattern Inside the Climatic Chamber

2004-11-16
2004-01-3254
For A/C and cooling systems development is usual send vehicles to US or Europe for wind tunnel tests, witch is expensive and has a long lead-time. Here in Brazil Delphi has at the Piracicaba Technical Center a chamber equipped with temperature control and chassis dynamometer. There is a up-grade project for it that consist in add ducts with fans inside the chamber that will get air from the chamber, already in the right temperature, accelerate and homogenate the air flow and blow it out direct to the front end of the vehicle. For development purposes may be possible eliminate totally the necessity of sending vehicle abroad. It was then decided to use CFD simulation to predict firstly the required fan power necessary to supply winds until 120 km/h at the front end of the vehicle and secondly predict the airflow pattern inside the chamber, considering chamber inlet air, chamber outlet air, exhaust outlet, duct outlet and flow pattern around the vehicle.
Technical Paper

Optimization of Oxygen Sensor

2000-03-06
2000-01-1364
Optimization of the mechanical aspects of a heated conical oxygen sensor for desired performances, such as low heater power, good poison resistance, fast light-off, and broad temperature range, etc. was achieved with computer modeling. CFD analysis was used to model the flow field in and around a sensor in an exhaust pipe to predict the convection coefficients, poisoning, and switching time. Heat transfer analysis coupled with electrical heating was applied to predict temperature and light-off time. Results of the optimization are illustrated, with good agreements between modeling and testing.
Technical Paper

Full Hybrid Electrical Vehicle Battery Pack System Design, CFD Simulation and Testing

2010-04-12
2010-01-1080
CFD analysis was performed using the FLUENT software to design the thermal system for a hybrid vehicle battery pack. The battery pack contained multiple modular battery elements, called bricks, and the inlet and outlet bus bars that electrically connected the bricks into a series string. The simulated thermal system was comprised of the vehicle cabin, seat cavity, inlet plenum, battery pack, a downstream centrifugal fan, and the vehicle trunk. The fan was modeled using a multiple reference frame approach. A full system analysis was done for airflow and thermal performance optimization to ensure the most uniform cell temperatures under all operating conditions. The mesh for the full system was about 13 million cells run on a 6-node HP cluster. A baseline design was first analyzed for fluid-thermal performance. Subsequently, multiple design iterations were run to create uniform airflow among all the individual bricks while minimizing parasitic pressure drop.
X