Refine Your Search

Topic

Author

Search Results

Journal Article

Start-Up Characteristics and Gravity Effects on a Medium/High-Lift Heat Pump using Advanced Hybrid Loop Technology

2008-06-29
2008-01-1959
Thermal characterization was performed on a vapor compression heat pump using a novel, hybrid two phase loop design. Previous work on this technology has demonstrated its ability to provide passive phase separation and flow control based on capillary action. This provides high quality vapor to the compressor without relying on gravity-based phase separation or other active devices. This paper describes the subsequent work done to characterize evaporator performance under various startup scenarios, tilt angles, and heat loads. The use of a thermal expansion valve as a method to regulate operation was investigated. The effect of past history of use on startup behavior was also studied. Testing under various tilt angles showed evaporator performance to be affected by both adverse and favorable tilts for the given compressor. And depending on the distribution of liquid in the system upon startup, markedly different performance can result for the same system settings and heat loads.
Technical Paper

The CEV Smart Buyer Team Effort: A Summary of the Crew Module & Service Module Thermal Design Architecture

2007-07-09
2007-01-3046
The NASA-wide CEV Smart Buyer Team (SBT) was assembled in January 2006 and was tasked with the development of a NASA in-house design for the CEV Crew Module (CM), Service Module (SM), and Launch Abort System (LAS). This effort drew upon over 250 engineers from all of the 10 NASA Centers. In 6 weeks, this in-house design was developed. The Thermal Systems Team was responsible for the definition of the active and passive design architecture. The SBT effort for Thermal Systems can be best characterized as a design architecting activity. Proof-of-concepts were assessed through system-level trade studies and analyses using simplified modeling. This nimble design approach permitted definition of a point design and assessing its design robustness in a timely fashion. This paper will describe the architecting process and present trade studies and proposed thermal designs
Technical Paper

Development of the Surface Thermal Environment for the Mars Scout Phoenix Mission

2007-07-09
2007-01-3239
Phoenix is NASA's first Mars Scouts Mission that will place a soft-lander on the Martian surface at a high northern latitude. Much of the Mars surface environmental flight data from landed missions pertains to the near-equatorial regions. However, orbital observations have yielded very useful data about the surface environment. These data along with a simple, but highly effective one-dimensional atmospheric model was used to develop the Phoenix surface thermal environment. As candidate landing sites were identified, parametric studies including statistical variations were conducted to prescribe minimum nighttime and maximum daytime temperature design Sols (a Martian day). Atmospheric effects such as clouds and ice were considered. Finally, recent candidate landing site imaging conducted by the Mars Reconnaissance Orbiter revealed that the prime site contained a much higher rock density than first thought.
Technical Paper

Development of the Third Generation JPL Electronic Nose for International Space Station Technology Demonstration

2007-07-09
2007-01-3149
The capabilities of the JPL Electronic Nose have been expanded to include characteristics required for a Technology Demonstration schedule on the International Space Station (ISS) in 2008-2009 [1,2]. Concurrently, to accommodate specific needs on ISS, the processes, tools and analyses which influence all aspects of development of the device have also been expanded. The Third Generation ENose developed for this program uses two types of sensor substrates, newly developed inorganic and organic sensor materials, redesigned electronics, onboard near real-time data analysis and power and data interfaces specifically for ISS. This paper will discuss the Third Generation ENose with a focus on detection of mercury in the parts-per-billion range.
Technical Paper

Overview of the Vehicle Cabin Atmosphere Monitor, a Miniature Gas Chromatograph/Mass Spectrometer for Trace Contamination Monitoring on the ISS and CEV

2007-07-09
2007-01-3150
Work is underway to deliver an instrument for analysis of the atmosphere aboard the International Space Station. The Vehicle Cabin Atmosphere Monitor (VCAM) is based on a low-mass, low-power miniature preconcentrator gas chromatograph/mass spectrometer (PCGC/MS) capable of providing sub-ppm measurements of volatile constituents in a space vehicle or outpost. VCAM is designed to operate autonomously, maintenance-free, once per day, with its own carrier and calibration gas supplies sufficient for a one-year lifetime. VCAM performance is sufficient to detect and identify 90% of the target compounds specified at their 180-day Spacecraft Maximum Allowable Concentration (SMAC) levels. The flight units will be delivered in mid-2008 and be operated in the ISS EXPRESS rack.
Technical Paper

Viral Populations within the International Space Station's Internal Active Thermal Control System Ground Support and Potential Flight Hardware

2007-07-09
2007-01-3108
The Internal Active Thermal Control System (IATCS) aboard the International Space Station (ISS) contains an aqueous, alkaline fluid (pH 9.5±0.5) that aids in maintaining a habitable environment for the crew. Because microbes have significant potential to cause disease, adverse effects on astronaut health, and microbe-induced corrosion, the presence of both bacteria and viruses within IATCS fluids is of concern. This study sought to detect and identify viral populations in IATCS samples obtained from the Kennedy Space Center as a first step towards characterizing and understanding potential risks associated with them. Samples were concentrated and viral nucleic acids (NA) extracted providing solutions containing 8.87-22.67 μg NA per mL of heat transfer fluid. After further amplification viral DNA and cDNA were then pooled, fluorescently labeled, and hybridized onto a Combimatrix panvira 12K microarray containing probes for ∼1,000 known human viruses.
Technical Paper

Measuring Aqueous Humor Glucose Across Physiological Levels: NIR Raman Spectroscopy, Multivariate Analysis, Artificial Neural Networks, and Bayesian Probabilities

1998-07-13
981598
We have elicited a reliable Raman spectral signature for glucose in rabbit aqueous humor across mammalian physiological ranges in a rabbit model stressed by recent myocardial infarction. The technique employs near infrared Raman laser excitation at 785 nm, multivariate analysis, non-linear artificial neural networks and an offset spectra subtraction strategy. Aqueous humor glucose levels ranged from 37 to 323 mg/dL. Data were obtained in 80 uL samples to anticipate the volume constraints imposed by the human and rabbit anterior chamber of the eye. Total sample collection time was 10 seconds with total power delivered to sample of 30 Mw. Spectra generated from the aqueous humor were compared qualitatively to artificial aqueous samples and an excitation offset technique was devised to counteract broadband background noise partially obscuring the glucose signature.
Technical Paper

Monitoring Space Shuttle Air for Selected Contaminants Using an Electronic Nose

1998-07-13
981564
A miniaturized electronic nose has been constructed at JPL in collaboration with Caltech. This array of conductometric sensors has been trained to detect and quantify the presence of vapors in the air; the compounds detected have been found as contaminants in shuttle air. This device has potential application as a miniature, distributed device for monitoring and controlling the constituents in air.
Technical Paper

Thermal Design of the Mars Science Laboratory Powered Descent Vehicle

2008-06-29
2008-01-2001
NASA's Mars Science Laboratory mission will use a Powered Descent Vehicle to accurately and safely land a roving, robotic laboratory on the surface of Mars. The precision landing systems employed on this vehicle are exposed to a wide range of mission environments from deep space cruise to atmospheric descent and require a robust and adaptable thermal design. This paper discusses the overall thermal design philosophy of the MSL Powered Descent Vehicle and presents analysis of the active and passive elements comprising the Cruise, Entry, Descent, and Landing thermal control systems.
Technical Paper

On-Orbit Performance of the TES Loop Heat Pipe Heat Rejection System

2008-06-29
2008-01-2000
Launched on NASA's Aura spacecraft on July 15, 2004, JPL's Tropospheric Emission Spectrometer (TES) has been operating successfully for over three years in space. TES is an infrared high resolution, imaging fourier transform spectrometer with spectral coverage of 3.3 to 15.4 μm to measure and profile essentially all infrared-active molecules present in the Earth's lower atmosphere. It measures the three-dimensional distribution of ozone and its precursors in the lower atmosphere on a global scale. The Aura spacecraft was successfully placed in a sun-synchronous near-circular polar orbit with a mean altitude of 705 km and 98.9 minute orbit period. The observatory is designed for a nominal 5 year mission lifetime. The instrument thermal design features include four temperature zones needed for efficient cryogenic staging to provide cooling at 65 K, 180 K, 230 K and 300 K.
Technical Paper

Thermal Vacuum Testing of the Moon Mineralogy Mapper Instrument

2008-06-29
2008-01-2037
The Moon Mineralogy Mapper (M3) instrument is scheduled for launch in 2008 onboard the Indian Chandrayaan-1 spacecraft. The mission is managed by the Indian Space Research Organization (ISRO) in Bangalore, India and is India's first flight to the Moon. M3 is being developed for NASA by the Jet Propulsion Laboratory under the Discovery Program Office managed by Marshall Space Flight Center. M3 is a state-of-the-art instrument designed to fulfill science and exploratory objectives. Its primary science objective is to characterize and map the lunar surface composition to better understand its geologic evolution. M3's primary exploration goal is to assess and map the Moon mineral resources at high spatial resolution to support future targeted missions. M3 is a cryogenic near infrared imaging spectrometer with spectral coverage of 0.4 to 3.0 μm at 10 nm resolution with high signal to noise ratio, spatial and spectral uniformity.
Technical Paper

Thermal Strategy for the Phoenix Robotic Arm Deployment

2009-07-12
2009-01-2438
The Mars Scout Phoenix Lander successfully landed in the Martian northern latitude on May 25, 2008. The Robotic Arm, which was designed to dig and to transfer soil samples to other Lander instruments, contained a number of actuators that had specific operational windows on the Martian surface due to the bearing lubricant. The deployment of the Robotic Arm was planned for Sol 2 (Mars days are referred to “Sols”). A few weeks before Mars landing, the Robotic Arm operations team learned that a strict flight rule had been imposed. It specified that the deployment shall be accomplished when the actuators were at or above −25°C since the deployment activity was qualified with the actuators at −40°C. Furthermore, the deployment plan identified a window of opportunity between 13:00 Local Solar Time (LST, equivalent to dividing the Sol into 24 equal Martian hours) and 15:30 LST.
Technical Paper

Monitoring Pre-Combustion Event Markers by Heating Electrical Wires

2009-07-12
2009-01-2543
Simultaneous measurements were made for particle releases and off-gassing products produced by heating electrical wires. The wire samples in these experiments were heated to selected temperatures in a heating chamber and responses to vapor releases were recorded by the JPL Electronic Nose (ENose) and an Industrial Scientific ITX gas-monitor; particles released were detected by a TSI P-Trak particle counter. The temperature range considered for the experiment is room temperature (24−26°C) to 500 °C. The results were analyzed by overlapping responses from the ENose, ITX gas sensors and P-Trak, to understand the events (particle release/off-gassing) and sequence of events as a function of temperature and to determine qualitatively whether ENose may be used to detect pre-combustion event markers.
Technical Paper

Mid-IR Semiconductor Lasers for Chemical Sensing

2003-07-07
2003-01-2551
The development of mid-IR semiconductor diode lasers based on type-II interband cascade structures is presented. How these diode lasers can be developed to meet the requirements in chemical sensing applications is discussed.
Technical Paper

Planar Array REDOX Cells and pH Sensors for ISS Water Quality and Microbe Detection

2003-07-07
2003-01-2553
This paper describes results acquired from E-Tongue 2 and E-Tongue 3 which are arrays of planar three-element electrochemical cells and pH sensors. The approach uses ASV (Anodic Stripping Voltammery) to achieve a detection limit, which in the case of Pb, is below one μM which is needed for water quality measurements. The richness of the detectable species is illustrated with Fe where seven species are identified using the Pourbiax diagram. The detection of multiple species is illustrated using Pb and Cu. The apparatus was used to detect the electroactivity of the metabolic-surrogate, PMS (phenazine-methosulphate). Finally, four types of pH sensors were fabricated and characterized for linearity, sensitivity, and responsiveness.
Technical Paper

Thermal Performance Evaluation of a Small Loop Heat Pipe for Space Applications

2003-07-07
2003-01-2688
A Small Loop Heat Pipe (SLHP) featuring a wick of only 1.27 cm (0.5 inches) in diameter has been designed for use in spacecraft thermal control. It has several features to accommodate a wide range of environmental conditions in both operating and non-operating states. These include flexible transport lines to facilitate hardware integration, a radiator capable of sustaining over 100 freeze-thaw cycles using ammonia as a working fluid and a structural integrity to sustain acceleration loads up to 30 g. The small LHP has a maximum heat transport capacity of 120 Watts with thermal conductance ranging from 17 to 21 W/°C. The design incorporates heaters on the compensation chamber to modulate the heat transport from full-on to full-stop conditions. A set of start up heaters are attached to the evaporator body using a specially designed fin to assist the LHP in starting up when it is connected to a large thermal mass.
Technical Paper

Investigation of Transient Temperature Oscillations of a Propylene Loop Heat Pipe

2001-07-09
2001-01-2235
A technology demonstration propylene Loop Heat Pipe (LHP) has been tested extensively in support of the implementation of this two-phase thermal control technology on NASA’s Earth Observing System (EOS) Tropospheric Emission Spectrometer (TES) instrument. This cryogenic instrument is being developed at the Jet Propulsion Laboratory (JPL) for NASA. This paper reports on the transient characterization testing results showing low frequency temperature oscillations. Steady state performance and model correlation results can be found elsewhere. Results for transient startup and shutdown are also reported elsewhere. In space applications, when LHPs are used for thermal control, the power dissipation components are typically of large mass and may operate over a wide range of power dissipations; there is a concern that the LHP evaporator may see temperature oscillations at low powers and over some temperature range.
Technical Paper

Trace Gas Analyzer for Extra-Vehicular Activity

2001-07-09
2001-01-2405
The Trace Gas Analyzer (TGA, Figure 1) is a self-contained, battery-powered mass spectrometer that is designed for use by astronauts during extravehicular activities (EVA) on the International Space Station (ISS). The TGA contains a miniature quadrupole mass spectrometer array (QMSA) that determines the partial pressures of ammonia, hydrazines, nitrogen, and oxygen. The QMSA ionizes the ambient gas mixture and analyzes the component species according to their charge-to-mass ratio. The QMSA and its electronics were designed, developed, and tested by the Jet Propulsion Laboratory (1,2). Oceaneering Space Systems supported JPL in QMSA detector development by performing 3D computer for optimal volumetric integration, and by performing stress and thermal analyses to parameterize environmental performance.
Technical Paper

Design and Flight Qualification of a Paraffin-Actuated Heat Switch for Mars Surface Applications

2002-07-15
2002-01-2275
The Mars Exploration Rover (MER) flight system uses mechanical, paraffin-actuated heat switches as part of its secondary battery thermal control system. This paper describes the design, flight qualification, and performance of the heat switch. Although based on previous designs by Starsys Research Corporation1,2, the MER mission requirements have necessitated new design features and an extensive qualification program. The design utilizes the work created by the expansion of a paraffin wax by bringing into contact two aluminum surfaces, thereby forming a heat conduction path. As the paraffin freezes and contracts, compression springs separate the surfaces to remove the conduction path. The flight qualification program involved extensive thermal performance, structural, and life testing.
X