Richard Viskup, Daniel Alberer, Klaus Oppenauer, Luigi del Re
Transient emission peaks have become an important fraction of the total emissions during the standardized test cycles for passenger car Diesel engines. To this end this paper is concerned with the challenge of measuring emissions during transients. The importance of this topic is increasing due to strict regulation on pollutant emissions. Hence, suitably accurate and fast measurement devices for PM emission detection are required. Thus, we present a comparison between different measurement techniques for Particulate matter (PM) emissions from a Diesel engine, in particular during transients. The compared equipments include AVL Micro soot sensor, AVL Opacimeter, Differential mobility spectrometer and Laser induced incandescence. The goal of this paper is to reveal the most accurate device in the sense of sensitivity and dynamics for fast measurements of PM from a Diesel engine.