Technical Paper

Computational Analysis of Biodiesel Combustion in a Low-Temperature Combustion Engine using Well-Defined Fuel Properties

2007-04-16
2007-01-0617
Biodiesel fuel can be produced from a wide range of source materials that affect the properties of the fuel. The diesel engine has become a highly tuned power source that is sensitive to these properties. The objectives of this research were to measure and predict the key properties of biodiesel produced from a broad range of source materials to be used as inputs for combustion modeling; and second to compare the results of the model with and without the biodiesel fuel definition. Substantial differences in viscosity, surface tension, density and thermal conductivity were obtained relative to reference diesel fuels and among the different source materials. The combustion model revealed differences in the temperature and emissions of biodiesel when compared to reference diesel fuel.
Technical Paper

An Experimental and Analytical Study of the Fatigue Life of Weldments with Longitudinal Attachments

2001-03-05
2001-01-0085
Both the experimental results and the analytical predictions of this study confirm that the poor fatigue performance of weldments with longitudinal attachments is due to poor weld quality which in turn leads to either a cold-lap or a very small weld toe radius. as well as to the combination of a very high 3-D stress concentration, and very high tensile residual stresses. Consequently, a specially designed stress-concentration-reducing part termed “stress diffuser” incorporated in the wrap-around welds at the ends of the longitudinal attachments increased the fatigue strength of longitudinal attachments to equal that of transverse attachments but only when cold-laps were eliminated. The fatigue life predictions made using the a two-stage Initiation-Propagation (IP) Model were in good agreement with the experimental results. Procedures for correcting for the curved shape of the crack path are investigated.
Technical Paper

Effects of Oxygenated Compounds on Combustion and Soot Evolution in a DI Diesel Engine:Broadband Natural Luminosity Imaging

2002-05-06
2002-01-1631
The detailed mechanisms by which oxygenated diesel fuels reduce engine-out soot emissions are not well understood. The literature contains conflicting results as to whether a fuel's overall oxygen content is the only important parameter in determining its soot-reduction potential, or if oxygenate molecular structure or other variables also play significant roles. To begin to resolve this controversy, experiments were conducted at a 1200-rpm, moderate-load operating condition using a modern-technology, 4-stroke, heavy-duty DI diesel engine with optical access. Images of broadband natural luminosity (i.e., light emission without spectral filtering) from the combustion chamber, coupled with heat-release and efficiency analyses, are presented for three test-fuels. One test-fuel (denoted GE80) was oxygenated with tri-propylene glycol methyl ether; the second (denoted BM88) was oxygenated with di-butyl maleate. The overall oxygen contents of these two fuels were matched at 26% by weight.
Technical Paper

The In-Situ Measurement of the Thermal Diffusivity of Combustion Chamber Deposits in Spark Ignition Engines

1992-02-01
920513
Combustion chamber deposits in spark ignition engines act as thermal insulators and can lead to octane requirement increase. The thermal properties of deposits are not well documented, the reported thermal diffusivity values vary by two orders of magnitude. Two thermal property measurement techniques were compared, the flash and steady illumination laser methods. The steady laser method was more suitable for deposit property measurement. A comparison was made of the thermal properties of deposits grown with a base fuel with the thermal properties of deposits grown with the base fuel doped with reformer bottoms. For the clean fuel the thermal diffusivity ranged from 3.5 to 3.9-7 m2/s, at various locations around the combustion chamber. For the fuel doped with reformer bottoms the thermal diffusivity ranged from 1.1 to 1.9-7 m2/s at different locations within the combustion chamber.
Technical Paper

Refrigerant Charge Imbalance in a Mobile Reversible Air Conditioning-Heat Pump System

2017-03-28
2017-01-0177
This paper presents the study of refrigerant charge imbalance between A/C (cooling) mode and HP (heating) mode of a mobile reversible system. Sensitivities of cooling and heating capacity and energy efficiency with respect to refrigerant charge were investigated. Optimum refrigerant charge level for A/C mode was found to be larger than that for HP mode, primarily due to larger condenser size in A/C mode. Refrigerant charge retention in components at both modes were measured in the lab by quick close valve method. Modeling of charge retention in heat exchangers was compared to experimental measurements. Effect of charge imbalance on oil circulation was also discussed.
Technical Paper

Experimentally Validated Effects of Separation of Liquid and Vapor on Performance of Condenser and System

2017-03-28
2017-01-0162
This paper presents the results of an experimental study to determine the effect of vapor-liquid refrigerant separation in a microchannel condenser of a MAC system. R134a is used as the working fluid. A condenser with separation and a baseline condenser identical on the air side have been tested to evaluate the difference in the performance due to separation. Two categories of experiments have been conducted: the heat exchanger-level test and the system-level test. In the heat exchanger-level test it is found that the separation condenser condenses from 1.6% to 7.4% more mass flow than the baseline at the same inlet and outlet temperature (enthalpy); the separation condenser condenses the same mass flow to a lower temperature than the baseline condenser does. In the system-level test, COP is compared under the same superheat, subcooling and refrigerating capacity. Separation condenser shows up to 6.6% a higher COP than the baseline condenser.
Technical Paper

Study of Biodiesel Combustion in a Constant Volume Chamber with Different Ambient Temperature and Oxygen Concentration

2011-08-30
2011-01-1931
Biodiesel is a widely used biofuel in diesel engines, which is of particular interest as a renewable fuel because it possesses the similar properties as the diesel fuel. The pure soybean biodiesel was tested in an optical constant volume combustion chamber using natural flame luminosity and forward illumination light extinction (FILE) methods to explore the combustion process and soot distribution at various ambient temperatures (800 K and 1000 K) and oxygen concentrations (21%, 16%, 10.5%). Results indicated that, with a lower ambient temperature, the autoignition delay became longer for all three oxygen concentrations and more ambient air was entrained by spray jet and more fuel was burnt by premixed combustion. With less ambient oxygen concentration, the heat release rate showed not only a longer ignition delay but also longer combustion duration.
Technical Paper

Performance Characteristics of a Mobile Heat Pump System at Low Ambient Temperature

2018-04-03
2018-01-0076
The demand for mobile heat pump systems increases with the growing popularity of electric vehicles. One big challenge of such systems using low pressure refrigerant is the substantial drop of heating capacity at low ambient temperature conditions, when heat is most needed. The low suction density associated with low operating pressure in the evaporator is the major reason for the capacity drop. In extremely low ambient temperature, compressor speed may need to be regulated in order to prevent suction pressure going below atmospheric pressure, hence further reducing heat pumping capability. Other factors like pressure drop induced temperature glide and refrigerant maldistribution in the outdoor evaporator also weakens the system ability to absorb heat from ambient air. This paper presents detailed and in-depth analysis of the performance and limiting factors on low ambient temperature operation of a mobile heat pump system using refrigerant R1234yf.
Technical Paper

Measurements of the Evaporation Behavior of the Film of Fuel Blends

2018-04-03
2018-01-0290
The formation of fuel film in the combustion cylinder affects the mixing process of the air and the fuel, and the process of the combustion propagation in engines. Some models of film evaporation have been developed to predict the evaporation behavior of the film, but rarely experimental results have been produced, especially when the temperature is high. In this study, the evaporation behavior of the film of different species of oil and their blends at different temperature are observed. The 45 μL films of isooctane, 1-propanol, 1-butanol, 1-pentanol, and their blends were placed on a quartz glass substrate in the closed temperature-controlled chamber. The shape change of the film during evaporation was monitored by a high-speed camera through the window of the chamber. First, the binary blends film of isooctane and one of the other three oils were evaporated at 30 °C, 50 °C, 70 °C and 90 °C.
Technical Paper

High Temperature Cyclic Fatigue Damage Modeling of Alumina

1994-03-01
940251
Cyclic loading is not as damaging as static loading of ceramics at high temperatures. Microcrack growth retardation has been established as a mechanism for increasing the durability of ceramics at high temperatures. A combined experimental and theoretical approach provides a mechanistic understanding of the deformation and failure processes in ceramic materials at high temperatures. Results demonstrate that the high temperature behavior of some ceramic material systems are controlled by the behavior of the grain boundary phase whose response is considerably different under static and cyclic loading.
Technical Paper

Analysis of Residual Stresses and Cyclic Deformation for Induction Hardened Components

1995-02-01
950707
Induction hardening of mild steel components often results in significant improvements in the static and cyclic load capability, with comparatively small increases in cost. Members subjected primarily to torsional loading are a relevant subset of the broad range of induction hardened components. Due to the variation of material properties and residual stresses, failures are “initiated” at the traditional geometric locations predicted for homogeneous materials and also at subsurface sites. The introduction of shear based fatigue parameters has necessitated the consideration of the residual stress as a three dimensional quantity, especially when analyzing subsurface failures. Not considering the tensoral nature of the residual stress can lead to serious errors when estimating fatigue life, and for larger magnitude loadings, the residual stress field may relax.
Technical Paper

An Investigation of the Feasibility of Refrigerant Charge Loss Detection Using Low Cost Measurements

1997-02-24
970106
The feasibility of automatically detecting refrigerant charge loss in mobile air conditioning (MAC) systems by analyzing inexpensive dynamic measurements was studied. An indicator of the refrigerant inventory of the evaporator was developed. This measure, termed Time to Temperature Turning (TTT), is based on dynamic measurement of the evaporator outlet refrigerant temperature, and correlates strongly with charge level. TTT correlated well with clutch cycling behavior, a metric which is employed in current shop diagnostic practice to indicate refrigerant charge loss. Laboratory data were generated from a factorial experiment design on the following factors: condenser air inlet temperature, condenser air flow rate, evaporator air inlet temperature, compressor speed, and refrigerant charge. Experiments to date were conducted with a dry evaporator.
Technical Paper

Analytical Descriptions of Service Loading Suitable for Fatigue Analysis

1997-04-08
971535
Service loading histories have the same general character for an individual route and the magnitudes vary from driver to driver. Both the magnitude and character of the loading history change from route to route and a linear scaling of one loading history does not characterize the variability of usage over a wide range of operating conditions. In this paper a technique for measuring and extrapolating cumulative exceedance diagrams to quantify the distribution of service loading in a vehicle is described. Monte Carlo simulations are coupled with the local stress strain approach for fatigue to obtain distributions of service loading. Fatigue life estimates based on the original loading histories are compared to those obtained from statistical descriptions of exceedance diagrams.
Technical Paper

Machinability of MADI™

2005-04-11
2005-01-1684
High strength materials have desirable mechanical properties but often cannot be machined economically, which results in unacceptably high finished component cost. MADI™ (machinable austempered ductile iron) overcomes this difficultly and provides the highly desirable combination of high strength, excellent low temperature toughness, good machinability and attractive finished component cost. The Machine Tool Systems Research Laboratory at the University of Illinois at Urbana-Champaign performed extensive machinability testing and determined the appropriate tools, speeds and feeds for milling and drilling (https://netfiles.uiuc.edu/malkewcz/www/MADI.htm). This paper provides the information necessary for the efficient and economical machining of MADI™ and provides comparative machinability data for common grades of ductile iron (EN-GJS-400-18, 400-15, 450-10, 500-7, 600-3 & 700-2) for comparison.
Technical Paper

An Empirical Method for Estimating the Fatigue Resistance of Tensile-Shear Spot Welds

1983-02-01
830035
An empirical method which is based principally on estimates of the fatigue crack initiation life (NI) has been developed which predicts the fatigue resistance of tensile-shear spot welds in the long life regime. The method uses Basquin’s law and Peterson’s equation to estimate NI and thus is founded on the fatigue behavior of smooth specimens and modelling of the fatigue notch size effect. The fatigue notch factor (Kf) required in this analysis was obtained from Pook’s relationships for the stress intensity factors of tensile-shear spot welds. Estimates of NI are added to estimates of the fatigue crack propagation life NP to obtain the total fatigue life (NT) but in the long life regime NP can usually be neglected. The improvement of tensile-shear spot weld fatigue resistance through manipulation of geometry and material property variables are discussed with the aid of the model.
Technical Paper

A Fatigue Life Prediction Method for Tensile-Shear Spot Welds

1985-02-01
850370
An empirical Three Stage Initiation-Propagation (TSIP) model has been developed which predicts the fatigue resistance of tensile-shear spot welds under constant amplitude loading. The improvements of tensile-shear spot weld fatigue resistance caused by changes in weld geometry, residual stresses and material properties variables are discussed with the aid of the model. The TSIP model suggests that, in addition to the influence of geometry, residual stresses at the site of crack initiation greatly influence the fatigue resistance of tensile-shear spot welds. The TSIP model predicts that material properties play a subtle role in determining the fatigue resistance of tensile-shear spot welds.
Technical Paper

A Sensor for Estimating the Liquid Mass Fraction of the Refrigerant Exiting an Evaporator

2000-03-06
2000-01-0976
A traditional method of controlling evaporator superheat in a vapor compression air conditioning system is the thermostatic expansion valve (TXV). Such systems are often used in automotive applications. The TXV depends on superheat to adjust the valve opening. Unfortunately, any amount of superheat causes that evaporator to operate at reduced capacity due to dramatically lower heat transfer coefficients in the superheated region. In addition, oil circulation back to the compressor is impeded. The cold lubricant almost devoid of dissolved refrigerant is quite viscous and clings to the evaporator walls. A system that could control an air conditioner to operate with no superheat would either decrease the size of its existing evaporator while maintaining the same capacity, or potentially increase its capacity with its original evaporator. Also, oil circulation back to the compressor would be improved.
Technical Paper

Methods for Detection of Lubrication Failure Applied to a Swashplate Compressor

2000-03-06
2000-01-0974
Understanding lubrication failures at the shoe/swashplate contact of automotive swashplate compressors will greatly enhance the reliability of the air conditioning system. Maintaining proper lubrication is not always possible during transient conditions. Therefore, a method for detection of lubricant loss is of great interest to the automotive industry. Three methods for detecting lubrication loss were examined: contact resistance, acoustic emission, and dynamic pressure oscillations. A mobile air conditioning test stand capable of recording many system parameters was used. Oil return to the compressor was monitored using an oil separator and a refrigerant/oil concentration sensor. Data were taken during steady oil return rates and after oil shut off. The electrical contact resistance between the shoe and swashplate was used to indicate changes in the lubrication conditions at this critical interface. Measurements were taken at two oil return rates during steady oil return tests.
Technical Paper

Experimental Investigation of Tripod Constant Velocity (CV) Joint Friction

2006-04-03
2006-01-0582
Constant Velocity (CV) joints are an integral part of modern vehicles, significantly affecting steering, suspension, and vehicle vibration comfort levels. Each driveshaft comprises of two types of CV joints, namely fixed and plunging types connected via a shaft. The main friction challenges in such CV joints are concerned with plunging CV joints as their function is to compensate for the length changes due to steering motion, wheel bouncing and engine movement. Although CV joints are common in vehicles, there are aspects of their internal friction and contact dynamics that are not fully understood or modeled. Current research works on modeling CV joint effects on vehicle performance assume constant empirical friction coefficient values. Such models, however are not always accurate, especially under dynamic conditions which is the case for CV tripod joints.
Journal Article

Efficiency Improvement by Separation of Vapor and Liquid in Condenser Headers

2017-03-28
2017-01-0180
This paper introduces the concept of separation of two-phase flow in condenser as a way to improve condenser efficiency. The benefits of vapor-liquid refrigerant separation and the reason why it will improve the condenser performance are explained. Numerical studies are presented on the effects of separation on performance of an R134a microchannel condenser, with the comparison to experiment data. Model predicts that at the same mass flow rate, the exit temperature is lower by 2.2 K in the separation condenser compared with that in the baseline. Up to 9% more flow rate of condensate is also predicted by the model in the separation condenser. Experiment results confirm the same trend. In addition, the reason why a certain circuiting of passes with pre-assumed separation results in the header improves the condenser is investigated by the model and results are presented.