Refine Your Search

Search Results

Viewing 1 to 3 of 3
Technical Paper

A Severe Ankle and Foot Injury in Frontal Crashes and Its Mechanism

1998-11-02
983145
In a frontal automotive crash, the driver's foot is usually stepping on the brake pedal as an instinctive response to avoid a collision. The tensile force generated in the Achilles tendon produces a compressive preload on the tibia. If there is intrusion of the toe board after the crash, an additional external force is applied to the driver's foot. A series of dynamic impact tests using human cadaveric specimens was conducted to investigate the combined effect of muscle preloading and external force. A constant tendon force was applied to the calcaneus while an external impact force was applied to the forefoot by a rigid pendulum. Preloading the tibia significantly increased the tibial axial force and the combination of these forces resulted in five tibial pylon fractures out of sixteen specimens.
Technical Paper

Dynamic Characteristics of the Human Spine During -Gx Acceleration

1978-02-01
780889
Spinal kinematics and kinetics of human cadaveric specimens subjected to -Gx acceleration are reported along with an attempt to design a surrogate spine for use in an anthropomorphic test device (ATD). There were a total of 30 runs on 9 embalmed and 2 unembalmed cadavers which were heavily instrumented. External photographic targets were attached to T1, T12, and the pelvis to record spinal kinematics. The subjects were restrained by upper and lower leg clamps attached to an impact seat equipped with a six-axis load cell. A rigid link 486 mm long and pinned at both ends was proposed for use in an ATD as a surrogate spine. An optimization method was used to obtain the location and length of a linkage which followed the least squares path of Tl relative to the pelvis.
Technical Paper

Dynamic Impact Loading of the Femur Under Passive Restrained Condition

1984-10-01
841661
The biodynamic response of the femur during passively restrained -Gx impact acceleration is reported in this paper. Eleven unembalmed cadavers, ranging in age from 21 to 65 and weighing from 50 to 96 kg, were tested in a VW Rabbit seat with a passive belt and knee restraint. Sectioned parts of the VW knee bolster were placed about 130 mm away from the patella at the initiation of the tests. The height of the knee bolsters was adjusted individually in the eleven tests. Ten were set for loading directly through the patella. In one run, the impact was below the knee joint. The sectioned bolsters were mounted on a rigid frame and instrumented with triaxial load cells. A six-axis load cell was installed in the right femur. Photo targets were attached directly to the femur and tibia. Sled runs were made at 22 and 35 g. Only one cadaver sustained bilateral femoral fractures at 35 g.
X