Refine Your Search

Search Results

Viewing 1 to 8 of 8
Standard

HFC-134a RECYCLING EQUIPMENT FOR MOBILE AIR-CONDITIONING SYSTEMS

1991-12-01
HISTORICAL
J2210_199112
The purpose of this SAE Recommended Practice is to establish the specific minimum equipment requirements for recycling HFC-134a that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems.
Standard

Method for Removal of Refrigerant from Mobile Air Conditioning System to Quantify Charge Amount

2017-03-10
CURRENT
J2762_201703
This Standard provides an overview of results and requirements needed to remove refrigerant from a mobile air conditioning system for determining refrigerant emissions (leakage). This reclaim procedure for use on fleet vehicles in a field service environment should produce an accuracy and repeatability sufficient to determine refrigerant loss within 2 g.
Standard

Method for Removal of Refrigerant from Mobile Air Conditioning System to Quantify Charge Amount

2011-02-04
HISTORICAL
J2762_201102
This Standard provides an overview of results and requirements needed to remove refrigerant from a mobile air conditioning system for determining refrigerant emissions (leakage). This reclaim procedure for use on fleet vehicles in a field service environment should produce an accuracy and repeatability sufficient to determine refrigerant loss within 2 g.
Standard

Minimum Performance Requirements for Non-Refrigerant Tracer Gasses and Electronic Tracer Gas Leak Detectors

2012-07-19
HISTORICAL
J2970_201207
This standard provides the testing and functional requirements guidance necessary for a leak detection device that uses any non-A/C refrigerant tracer gas, such as helium or a nitrogen-hydrogen blend, to provide functional performance equivalent to a refrigerant electronic leak detector. It explains how a non- refrigerant leak detector’s calibration can be established to provide levels of detection equal to electronic leak detectors that meet SAE J2791 for R-134a and SAE J2913 for R-1234yf.
Standard

Minimum Performance Requirements for Non-Refrigerant Tracer Gasses and Electronic Tracer Gas Leak Detectors

2015-03-17
HISTORICAL
J2970_201503
This standard provides the testing and functional requirements guidance necessary for a leak detection device that uses any non-A/C refrigerant tracer gas, such as helium or a nitrogen-hydrogen blend, to provide functional performance equivalent to a refrigerant electronic leak detector. It explains how a non- refrigerant leak detector’s calibration can be established to provide levels of detection equal to electronic leak detectors that meet SAE J2791 for R-134a and SAE J2913 for R-1234yf.
Standard

Minimum Performance Requirements for Non-Refrigerant Tracer Gases and Electronic Tracer Gas Leak Detectors

2023-05-01
CURRENT
J2970_202305
This SAE Standard provides the testing and functional requirements guidance necessary for a leak detection device that uses any non-A/C refrigerant tracer gas, such as helium or a nitrogen-hydrogen blend, to provide functional performance equivalent to a refrigerant electronic leak detector. It explains how a non-refrigerant leak detector’s calibration can be established to provide levels of detection equal to electronic leak detectors that meet SAE J2791 for R-134a and SAE J2913 for R-1234yf.