Criteria

Text:
Topic:
Display:

Results

Viewing 1 to 30 of 44
CURRENT
2011-11-21
Standard
J1732_201111
The purpose of this SAE Standard is to provide equipment specifications for the recovery of HFC-134a (R-134a) refrigerant to be returned to a refrigerant reclamation facility that will process it to the appropriate ARI 700 Standard or allow for recycling of the recovered refrigerant to SAE J2210 specifications by using Design Certified equipment of the same ownership. It is not acceptable that the refrigerant removed from a mobile air-conditioning (A/C) system, with this equipment be directly returned to a mobile A/C system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar HFC-134a (R-134a) A/C systems.
CURRENT
2010-11-05
Standard
J1770_201011
The purpose of this SAE Standard is to establish the specific minimum equipment requirements for recovery/recycling equipment intended for use with both R12 and R134a in a common refrigerant circuit that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. This document does not apply to equipment used for R12 and R134a having a common enclosure with separate circuits for each refrigerant.
CURRENT
2011-05-26
Standard
J1771_201105
This SAE Standard applies to refrigerant identification equipment to be used for identifying refrigerant CFC-12 (R-12) and HFC-134a (R-134a) refrigerant when servicing a mobile A/C system or for identifying refrigerant in a container to be used to charge a mobile A/C system. Identification or other refrigerants are the option of the equipment manufacturer.
CURRENT
2011-04-01
Standard
J1661_201104
The purpose of this SAE Recommended Practice is to provide a service procedure for retrofitting a CFC-12 (R-12) system to HFC-134a (R-134a) while preserving performance and integrity of the air-conditioning (A/C) system. The steps outlined in this procedure are complete when combined with good service practices and the vehicle manufacturer's recommendations (if available) for retrofitting their models. Separate service equipment, for CFC-12 (R-12) and HFC-134a (R-134a), including refrigerant recovery/ recycle (R/R), service manifolds, vacuum pumps, and charging equipment shall be used to preserve the purity of the refrigerants and the mobile A/C systems. This procedure will minimize release of refrigerant to the atmosphere, and will preserve the integrity of the recycled CFC-12 (R-12) and HFC-134a (R-134a) supplies. This document applies to A/C systems used to cool the passenger compartment of automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems.
CURRENT
2011-04-01
Standard
J1627_201104
This SAE Standard applies to electronic probe-type leak detectors used to service motor vehicle passenger compartment air-conditioning systems. This document does not address any safety issues concerning their design or use.
CURRENT
2014-07-24
Standard
J1628_201407
This SAE Recommended Practice applies to the use of generally available leak detection methods to service motor vehicle passenger compartment air conditioning systems.
HISTORICAL
2011-08-29
Standard
J1628_201108
This SAE Recommended Practice applies to the use of generally available leak detection methods to service motor vehicle passenger compartment air conditioning systems.
CURRENT
2011-04-01
Standard
J1657_201104
The purpose of this SAE Recommended Practice is to provide criteria for determining the acceptability of candidate retrofit refrigerants to replace CFC-12 (R-12) in mobile A/C systems originally designed to use CFC-12 (R-12).
CURRENT
2011-05-26
Standard
J1990_201105
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recycling equipment. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) air-conditioning (A/C) systems. Systems used on mobile vehicles for refrigerating cargo that have hermetically sealed systems are not covered in this document. The equipment in this document is intended for use with refrigerant that has been directly removed from, and intended to be returned to, a mobile A/C system. Should other revisions due to operational or technical requirements occur, this document may be amended.
CURRENT
2011-05-26
Standard
J1989_201105
During service of mobile air-conditioning (A/C) systems, containment of the refrigerant is important. This procedure provides service guidelines for technicians when repairing vehicles and operating equipment defined in SAE J1990.
CURRENT
2011-08-12
Standard
J2209_201108
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recovery for return to a refrigerant reclamation facility that will process it to the appropriate ARI Standard (Air Conditioning and Refrigerant Institute) or allow for recycling of the recovered refrigerant in equipment that is certified to meet the requirements of SAE J1991. Under the existing rule, the U.S. EPA requires refrigerant removed from a mobile air-conditioning (A/C) system using recovery equipment certified to meet SAE J2209 can only be recycled using equipment meeting SAE J1991 that is owned by the same company or individual. It is not acceptable that the refrigerant removed from a mobile A/C system, with this equipment, be directly returned to a mobile A/C system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems.
CURRENT
2011-11-21
Standard
J2211_201111
Refrigerant containment is an important part of servicing mobile air-conditioning (A/C) systems. This procedure provides guidelines for technicians for servicing mobile A/C systems and operating refrigerant recycling equipment designed for HFC-134a (R-134a) (described in SAE J2210).
CURRENT
2011-11-21
Standard
J2196_201111
This SAE Standard covers reinforced rubber, reinforced thermoplastic, or otherwise constructed hose, or hose assemblies, intended for conducting liquid and gaseous refrigerants for service connections from mobile air conditioning systems to service equipment such as a manifold gauge set and vacuum pumps or for use internally, in charging stations or service equipment intended for use in servicing mobile air-conditioning systems.
CURRENT
2011-08-12
Standard
J2298_201108
This SAE Standard applies to the application of ultraviolet leak detection to service mobile air-conditioning systems.
CURRENT
2015-03-17
Standard
J2970_201503
This standard provides the testing and functional requirements guidance necessary for a leak detection device that uses any non-A/C refrigerant tracer gas, such as helium or a nitrogen-hydrogen blend, to provide functional performance equivalent to a refrigerant electronic leak detector. It explains how a non- refrigerant leak detector’s calibration can be established to provide levels of detection equal to electronic leak detectors that meet SAE J2791 for R-134a and SAE J2913 for R-1234yf.
HISTORICAL
2012-07-19
Standard
J2970_201207
This standard provides the testing and functional requirements guidance necessary for a leak detection device that uses any non-A/C refrigerant tracer gas, such as helium or a nitrogen-hydrogen blend, to provide functional performance equivalent to a refrigerant electronic leak detector. It explains how a non- refrigerant leak detector’s calibration can be established to provide levels of detection equal to electronic leak detectors that meet SAE J2791 for R-134a and SAE J2913 for R-1234yf.
CURRENT
2015-07-08
Standard
J3030_201507
The purpose of this SAE Standard is to establish the specific minimum equipment requirements for recovery/recycling/recharge equipment intended for use with both R-1234yf and R-134a in a common refrigerant circuit that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. This document does not apply to equipment used for R-1234yf and R-134a having a common enclosure with separate circuits for each refrigerant, although some amount of separate circuitry for each refrigerant could be used.
HISTORICAL
2011-02-04
Standard
J2843_201102
This SAE Standard applies to equipment to be used with R-1234yf refrigerant only. It establishes requirements for equipment used to recharge R-1234yf to an accuracy level that meets Section 9 of this document and purity levels defined in SAE J2099. Refrigerant service equipment is required to ensure adequate refrigerant recovery to reduce emissions and provide for accurate recharging of mobile air conditioning systems. Equipment shall be certified to meet all performance requirements outlined in this document and international/regional construction and safety requirements as outlined in this document.
CURRENT
2013-01-14
Standard
J2845_201301
Technician training is required to ensure that recommended procedures are used for service and repair of Mobile Air Conditioning (MAC) systems using R-744 and/or R-1234yf. Unique requirements for each refrigerant are detailed within this standard. Technicians may be trained in either or both refrigerants. The technician shall be trained to recognize which refrigerant is being handled, how to handle it safely and be equipped with the essential information, proper equipment and tools, which are unique to these refrigerants. This standard outlines minimum content requirements for such training programs. Training programs designed in accordance with this standard are not intended to ensure or assess the technical skills of technicians regarding the diagnosis and repair of motor vehicle air conditioners. Rather, the goal of such programs is to provide information to technicians about safely handling refrigerants.
HISTORICAL
2011-10-04
Standard
J2845_201110
Technician training is required to ensure that recommended procedures are used for service and repair of Mobile Air Conditioning (MAC) systems using R-744 and/or R-1234yf. Unique requirements for each refrigerant are detailed within this standard. Technicians may be trained in either or both refrigerants. The technician shall be trained to recognize which refrigerant is being handled, how to handle it safely and be equipped with the essential information, proper equipment and tools, which are unique to these refrigerants. This standard outlines minimum content requirements for such training programs. Training programs designed in accordance with this standard are not intended to ensure or assess the technical skills of technicians regarding the diagnosis and repair of motor vehicle air conditioners. Rather, the goal of such programs is to provide information to technicians about safely handling refrigerants.
CURRENT
2013-01-14
Standard
J2843_201301
This SAE Standard applies to equipment to be used with R-1234yf refrigerant only. It establishes requirements for equipment used to recharge R-1234yf to an accuracy level that meets Section 9 of this document and purity levels defined in SAE J2099. Refrigerant service equipment is required to ensure adequate refrigerant recovery to reduce emissions and provide for accurate recharging of mobile air conditioning systems. Equipment shall be certified to meet all performance requirements outlined in this document and international/regional construction and safety requirements as outlined in this document.
HISTORICAL
2012-02-17
Standard
J2843_201202
This SAE Standard applies to equipment to be used with R-1234yf refrigerant only. It establishes requirements for equipment used to recharge R-1234yf to an accuracy level that meets Section 9 of this document and purity levels defined in SAE J2099. Refrigerant service equipment is required to ensure adequate refrigerant recovery to reduce emissions and provide for accurate recharging of mobile air conditioning systems. Equipment shall be certified to meet all performance requirements outlined in this document and international/regional construction and safety requirements as outlined in this document.
HISTORICAL
2011-02-04
Standard
J2845_201102
Technician training is required to ensure that recommended procedures are used for service and repair of Mobile Air Conditioning (MAC) systems using R-744 and/or R-1234yf. Unique requirements for each refrigerant are detailed within this standard. Technicians may be trained in either or both refrigerants. The technician shall be trained to recognize which refrigerant is being handled, how to handle it safely and be equipped with the essential information, proper equipment and tools, which are unique to these refrigerants. This standard outlines minimum content requirements for such training programs. Training programs designed in accordance with this standard are not intended to ensure or assess the technical skills of technicians regarding the diagnosis and repair of motor vehicle air conditioners. Rather, the goal of such programs is to provide information to technicians about safely handling refrigerants.
CURRENT
2016-03-11
Standard
J2810_201603
The purpose of this SAE Standard is to provide minimum performance and operating feature requirements for the recovery of HFC-134a (R-134a) refrigerant to be returned to a refrigerant reclamation facility that will process it to the appropriate AHRI 700 Standard or allow for on-site recycling of the recovered refrigerant to SAE J2788 specifications by using SAE J2788 or SAE J3030 -certified equipment. It is not acceptable that the refrigerant removed from a mobile air-conditioning (A/C) system with this equipment be directly returned to a mobile A/C system. An identifier certified to SAE J2912 is to be used to identify the contents of the system prior to recovery of the refrigerant.
HISTORICAL
2007-10-11
Standard
J2810_200710
The purpose of this SAE Standard is to provide minimum performance and operating feature requirements for the recovery of HFC-134a (R-134a) refrigerant to be returned to a refrigerant reclamation facility that will process it to the appropriate ARI 700 Standard or allow for recycling of the recovered refrigerant to SAE J2788 specifications by using SAE J2788-certified equipment. It is not acceptable that the refrigerant removed from a mobile air-conditioning (A/C) system with this equipment be directly returned to a mobile A/C system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar HFC-134a (R-134a) A/C systems.
HISTORICAL
2011-02-07
Standard
J2912_201102
This SAE Standard applies to refrigerant identification equipment to be used for identifying refrigerant HFC-134a (R-134a) and/or HFO-1234yf (R-1234yf) refrigerant when servicing a mobile A/C system or for identifying refrigerant in a container to be used to charge a mobile A/C system. Identification or other refrigerants are the option of the equipment manufacturer, although it shall not misidentify refrigerants, per 3.2.
HISTORICAL
2013-11-20
Standard
J2912_201311
This SAE Standard applies to refrigerant identification equipment to be used for identifying refrigerant HFC-134a (R-134a) and HFO-1234yf (R-1234yf) refrigerant when servicing a mobile A/C system or for identifying refrigerant in a container to be used to charge a mobile A/C system. Identification of other refrigerants is the option of the equipment manufacturer, although it shall not misidentify refrigerants, per 3.2.
CURRENT
2014-12-11
Standard
J2912_201412
This SAE Standard applies to refrigerant identification equipment to be used for identifying refrigerant HFC-134a (R-134a) and HFO-1234yf (R-1234yf) refrigerant when servicing a mobile A/C system or for identifying refrigerant in a container to be used to charge a mobile A/C system. Identification of other refrigerants is the option of the equipment manufacturer, although it shall not misidentify refrigerants, per 3.2.
HISTORICAL
2011-10-04
Standard
J2912_201110
This SAE Standard applies to refrigerant identification equipment to be used for identifying refrigerant HFC-134a (R-134a) and HFO-1234yf (R-1234yf) refrigerant when servicing a mobile A/C system or for identifying refrigerant in a container to be used to charge a mobile A/C system. Identification of other refrigerants is the option of the equipment manufacturer, although it shall not misidentify refrigerants, per 3.2.
HISTORICAL
2012-07-16
Standard
J2912_201207
This SAE Standard applies to refrigerant identification equipment to be used for identifying refrigerant HFC-134a (R-134a) and HFO-1234yf (R-1234yf) refrigerant when servicing a mobile A/C system or for identifying refrigerant in a container to be used to charge a mobile A/C system. Identification of other refrigerants is the option of the equipment manufacturer, although it shall not misidentify refrigerants, per 3.2.
Viewing 1 to 30 of 44