Refine Your Search

Search Results

Viewing 1 to 13 of 13
Journal Article

Heavy Duty Particle Measurement Programme (PMP): Exploratory Work for the Definition of the Test Protocol

2009-06-15
2009-01-1767
The heavy duty Particle Measurement Programme (PMP) inter-laboratory exercise consists of three parts: 1) the exploratory work to refine the measurement protocol, 2) the validation exercise where each lab will measure the emissions of a “golden” engine with two “golden” particle number systems simultaneously sampling from full and partial flow dilution systems, and 3) the round-robin where the emissions of a “reference” engine will be determined with a lab’s own particle number instrumentation. This paper presents the results of the exploratory work and describes the final protocol for testing in the validation exercise (and round robin) along with the necessary facility modifications required for compliance with the protocol. Key aspects of the protocol (e.g. filter material, flow rates at the full and partial flow systems, the pre-conditioning etc.) are explained and justified.
Technical Paper

On-Road Emissions of Euro 6d-TEMP Vehicles: Consequences of the Entry into Force of the RDE Regulation in Europe

2020-09-15
2020-01-2219
Human health and the environment are heavily impacted by air pollution. Air quality standards for Nitrogen dioxide (NO2) and particulate matter (PM) are commonly exceeded in Europe, particularly in urban areas with high density of traffic. Road transport contributed to 39% of NOx emissions, and 11% of PM emissions in the European Union (EU) in 2017. Measurements with Portable Emissions Measurement Systems (PEMS) showed that most Euro 5 and Euro 6b diesel vehicles emitted significantly more NOx on the road than their permissible limit in the laboratory type-approval test. In that context, EU Real Driving Emissions (EU-RDE) regulation aims at securing low on-road emissions of light duty vehicles under normal conditions of use. This paper assesses the tailpipe emissions performance of Euro 6d-TEMP gasoline and diesel passenger cars, type-approved after the entry into force of the RDE regulation in September 2017.
Journal Article

On-Site Checks of the Particle Number Measurement Systems with Polydisperse Aerosol

2012-04-16
2012-01-0873
Since 2011 a particle number (PN) limit was introduced in the European light-duty diesel vehicles legislation. The PN measurement systems consist of i) a hot diluter and an evaporation tube at 300-400°C for the removal of the volatiles (Volatile Particle Remover, VPR) and ii) a particle number counter (PNC) with a 50% cut-point (cut-off) at 23 nm. The PN measurement systems are calibrated and validated annually with monodisperse aerosol: The VPR for the particle concentration reduction factor (PCRF) and the PNC for the linearity and the cut-off size. However, there are concerns that the PN measurement systems can drift significantly over this period of time, raising concerns regarding the validity of the previous measurements, especially if the yearly validation fails.
Journal Article

Sampling of Non-Volatile Vehicle Exhaust Particles: A Simplified Guide

2012-04-16
2012-01-0443
Recently, a particle number (PN) limit was introduced in the European light-duty vehicles legislation. The legislation requires measurement of PN, and particulate mass (PM), from the full dilution tunnel with constant volume sampling (CVS). Furthermore, PN measurements will be introduced in the next stage of the European Heavy-Duty regulation. Heavy-duty engine certification can be done either from the CVS or from a partial flow dilution system (PFDS). For research and development purposes, though, measurements are often conducted from the raw exhaust, thereby avoiding the high installation costs of CVS and PFDS. Although for legislative measurements requirements exist regarding sampling and transport of the aerosol sample, such requirements do not necessarily apply for raw exhaust measurements. Thus, measurement differences are often observed depending on where in the experimental set up sampling occurs.
Journal Article

Engine Exhaust Solid Sub-23 nm Particles: I. Literature Survey

2014-10-13
2014-01-2834
In the current diesel vehicle exhaust emissions legislation Particle Number (PN) limits for solid particles >23 nm are prescribed. The legislation was extended to include Gasoline Direct Injection (G-DI) vehicles since September 2014. Target of this paper was to investigate whether smaller than 23 nm solid particles are emitted from engines in considerable concentration focusing on G-DI engines. The literature survey and the experimental investigation of >15 vehicles showed that engines emit solid sub-23 nm particles. The average percentage over a test cycle for G-DIs (30-40%) is similar to diesel engines. These percentages are relatively low considering the emission limit levels (6×1011 p/km) and the repeatability (10-20%) of the particle number method. These percentages are slightly higher compared to the percentages expected theoretically not to be counted due to the 23 nm cut-off size (5-15%).
Technical Paper

Comparison of Particle Number Measurements from the Full Dilution Tunnel, the Tailpipe and Two Partial Flow Systems

2010-04-12
2010-01-1299
The regulation of particle number (PN) has been introduced in the Euro 5/6 light-duty vehicle legislation, as a result of the light duty inter-laboratory exercise of the Particle Measurement Program (PMP). The heavy-duty inter-laboratory exercise investigates whether the same or a similar procedure can be applied to the heavy-duty regulation. In the heavy-duty exercise two "golden" PN systems sample simultaneously; the first from the full dilution tunnel and the second from the partial flow system. One of the targets of the exercise is to compare the PN results from the two systems. In this study we follow a different approach: We use a PMP compliant system at different positions (full flow, partial flow and tailpipe) and we compare its emissions with a "reference" system always sampling from the full flow dilution tunnel.
Technical Paper

Diesel Particulate Measurement with Partial Flow Sampling: Systems A New Probe and Tunnel Design that Correlates with Full Flow Tunnels

2002-03-04
2002-01-0054
Partial flow sampling methods in emissions testing are interesting and preferred because of their lower cost, smaller size and applicability to engines of all sizes. However the agreement of the results obtained with instruments based on this method to those obtained with the traditional, large tunnel full flow sampling systems needs to be achieved, and the factors of construction that influence this agreement must be understood. These issues have received more attention lately in connection with ISO and WHDC standardization efforts underway to achieve a world-wide harmony in the sampling methods for heavy duty diesel engines, and with the introduction of similar Bag-minidiluter techniques into light duty SULEV gaseous pollutant measurement. This paper presents the theory and practice of a partial flow probe and tunnel design that addresses and minimizes the undesirable effects of the necessary differences between the two sampling methods.
Technical Paper

Particle Emissions Characteristics of Different On-Road Vehicles

2003-05-19
2003-01-1888
Due to the stringent emission standards set worldwide, particulate matter (PM) emissions from diesel vehicles have been significantly curtailed in the last decade, and are expected to be reduced even further in the future. This evolution has brought forward two main issues: whether PM emissions should only be regulated for diesel vehicles and whether gasoline powered vehicles can be further neglected from PM emission inventories. This paper addresses these issues comparing the characteristics of particle emissions from a current diesel passenger car, a gasoline one and two small two-wheelers. It is shown that the gasoline car is a negligible source of particle emissions while the two-wheelers may be even more significant particle sources than the diesel car.
Technical Paper

Accuracy of Particle Number Measurements from Partial Flow Dilution Systems

2011-09-11
2011-24-0207
The measurement of the particle number (PN) concentration of non-volatile particles ≻23 nm was introduced in the light-duty vehicles regulation; the heavy-duty regulation followed. Based on the findings of the Particle Measurement Program (PMP), heavy-duty inter-laboratory exercise, the PN concentration measurement can be conducted either from the full dilution tunnel with constant volume sampling (CVS) or from the partial flow dilution system (PFDS). However, there are no other studies that investigate whether the PN results from the two systems are equivalent. In addition, even the PMP study never investigated the uncertainty that is introduced at the final result from the extraction of a flow by a PN system from the PFDS. In this work we investigate the uncertainty for the three possible cases, i.e., considering a constant extracted flow from the PFDS, sending a signal with 1 Hz frequency to the PFDS, or feeding back the extracted flow to the PFDS.
Technical Paper

Feasibility of Particulate Mass and Number Measurement with Portable Emission Measurement Systems (PEMS) for In-Use Testing

2011-09-11
2011-24-0199
Different particulate mass (PM) portable emission measurement systems (PEMS) were evaluated in the lab with three heavy-duty diesel engines which cover a wide range of particle emission levels. For the two engines without Diesel Particulate Filters (DPF) the proportional partial flow dilution systems SPC-472, OBS-TRPM, and micro-PSS measured 15% lower PM than the full dilution tunnel (CVS). The micro soot sensor (MSS), which measures soot in real time, measured 35% lower. For the DPF-equipped engine, where the emissions were in the order of 2 mg/kWh, the systems had differences from the CVS higher than 50%. For on-board testing a real-time sensor is necessary to convert the gravimetric (filter)-based PM to second-by-second mass emissions. The detection limit of the sensor, the particle property it measures (e.g., number, surface area or mass, volatiles or non-volatiles) and its calibration affect the estimated real-time mass emissions.
Technical Paper

A New Device for Transient Measurement of Ultralow Soot Emissions

2004-11-16
2004-01-3267
Future legislation, like EURO IV and EURO V or the US 2007 HD regulation will have massive reduction of particulate emission limits. For this beside improvement of engine combustion also exhaust aftertreatment systems are under investigation, like Diesel Particulate Filters (DPF), or Selective Catalytic Reduction (SCR) of Nitrogen Oxides. For all those tasks transient soot emission monitoring is one of the key features. To meet this demand a new device for the on-line measurement of soot emitted by combustion engines has been developed. Based on the photoacoustic principle, which has been optimized for automotive applications and easy use in test cells, the instrument shows a sensitivity of 5μg/m3, which is lower than current particulate immission standards in ambient air, and a time resolution of 1 sec. In the paper first the principles of measurement are shown, and then the specifications and results from measurements of very low soot concentration in the exhaust gas are presented.
Technical Paper

Dynamic Measurements of Particulate Mass Emission on Light-Duty Diesel Engines under Steady State and Transient Conditions

1985-03-01
850269
Real-time measurements of the particulate emission of a light duty Diesel engine mounted on a dynamic test bed are reported. These measurements were performed using a novel device for the simultaneous dynamic determination of graphitic (“black”) smoke and hydrocarbon mass loading in the undiluted exhaust with a time resolution of 0.1 sec. For a given speed and load significant differences between the emissions under steady state and transient conditions were observed. The typical features of these deviations were different for the graphitic particulates and the hydrocarbons.
Journal Article

Development of Measurement Methodology for Sub 23 nm Particle Number (PN) Measurements

2020-09-15
2020-01-2211
A proposal for sub-23 nm Solid Particle Number (SPN) measurement method was developed by the Particle Measurement Programme (PMP) group, based on the current SPN measurement method. In the proposal, a Particle Number Counter (PNC) having (65 ± 15)% counting efficiency at 10 nm and >90% at 15 nm (PNC10) replaces the current regulation PNC efficiency of 50±12% at 23 nm and >90% at 41 nm. Additionally, a catalytically active evaporation tube (CS) is required for sub-23 nm measurement method instead of the non-reactive evaporation tube (ET) of the current regulation. Here experimental work carried out at the JRC to address the issues of sub-23 nm SPN-measurement method is presented. The PNC10 was shown to be less dependent on the particle material than the PNC23, thus soot-like particles are still allowed for PNC-calibration. The high charging probability of soot-like particles was shown to have a low effect on PNC calibration uncertainties.
X