Criteria

Text:
Display:

Results

Viewing 1 to 29 of 29
HISTORICAL
1982-08-01
Standard
J1299_198208
This SAE Information Report applies to the control circuits and devices associated with the electrical propulsion system used on electric drive dumpers. Dumper is defined in J/ISO 6165. The document does not apply to auxiliary equipment control systems such as: Battery charging systems Engine wiring and control Monitoring and control circuits not directly affecting the operation of the electric propulsion and retarding system Lighting Accessory systems (heating, air conditioning, horns, radios, emergency steering, fire protection, and similar functions). Purpose This document establishes requirements for the control circuits and control devices of the electric propulsion system of an electric drive dumper. Criteria are established for environmental service conditions, control systems requirements, control device operational requirements and control tests.
HISTORICAL
2003-09-09
Standard
J1299_200309
This SAE Information Report applies to the control circuits and devices associated with the electrical propulsion system used on electric drive dumpers. Dumper is defined in J/ISO 6165. The document does not apply to auxiliary equipment control systems such as: Battery charging systems Engine wiring and control Monitoring and control circuits not directly affecting the operation of the electric propulsion and retarding system Lighting Accessory systems (heating, air conditioning, horns, radios, emergency steering, fire protection, and similar functions). Purpose This document establishes requirements for the control circuits and control devices of the electric propulsion system of an electric drive dumper. Criteria are established for environmental service conditions, control systems requirements, control device operational requirements and control tests.
CURRENT
2013-02-21
Standard
J1299_201302
This SAE Information Report applies to the control circuits and devices associated with the electrical propulsion system used on electric drive dumpers. Dumper is defined in J/ISO 6165. The document does not apply to auxiliary equipment control systems such as: Battery charging systems Engine wiring and control Monitoring and control circuits not directly affecting the operation of the electric propulsion and retarding system Lighting Accessory systems (heating, air conditioning, horns, radios, emergency steering, fire protection, and similar functions).
CURRENT
2013-02-21
Standard
J1317_201302
This recommended practice applies to the rotating equipment in the electrical propulsion systems on electrically propelled dumpers. It also applies to the rotating equipment installed on trailers connected to electrically propelled dumpers. The recommended practice does not apply to rotating equipment such as windshield wiper motors, battery charging generators, etc. that may be used on dumpers.
HISTORICAL
1982-06-01
Standard
J1317_198206
This recommended practice establishes criteria for environmental service conditions, ratings, and test methods of electrical propulsion rotating equipment. This recommended practice applies to the rotating equipment in the electrical propulsion systems on electrically propelled dumpers. It also applies to the rotating equipment installed on trailers connected to electrically propelled dumpers. The recommended practice does not apply to rotating equipment such as windshield wiper motors, battery charging generators, etc., that may be used on dumpers.
HISTORICAL
2002-01-31
Standard
J180_200201
This SAE document describes alternator physical, performance and application requirements for heavy-duty electrical charging systems for on and off road applications including those defined in SAE J1116. The purpose of this SAE document is to provide information on which to base machine and component design and to establish minimum requirements which will result in the most satisfactory operation of charging systems in construction, agricultural, and industrial machinery environments.
HISTORICAL
2010-05-11
Standard
J1810_201005
This SAE Standard describes those factors which affect the accuracy and reliability of voltage indicating units and electrical indicating and sending units for fuel level, pressure, and temperature suitable for off-road, self-propelled work machines as described in SAE J1116 and agricultural tractors as defined in ASAE S390. Indicating units are divided into two groups, fully sealed and partially sealed. Serviceable lighting is not covered by this document unless otherwise specified. No ISO document has been found to be compatible.
CURRENT
2015-10-08
Standard
J1810_201510
This SAE Standard describes those factors which affect the accuracy and reliability of voltage indicating units and electrical indicating and sending units for fuel level, pressure, and temperature suitable for off-road, self-propelled work machines as described in SAE J1116 and agricultural tractors as defined in ASAE S390. Indicating units are divided into two groups, fully sealed and partially sealed. Serviceable lighting is not covered by this document unless otherwise specified. No ISO document has been found to be compatible.
HISTORICAL
2002-04-02
Standard
J1810_200204
This SAE Standard describes those factors which affect the accuracy and reliability of voltage indicating units and electrical indicating and sending units for fuel level, pressure, and temperature suitable for off-road, self-propelled work machines as described in SAE J1116. Indicating units are divided into two groups, fully sealed and partially sealed. Serviceable lighting is not covered by this document unless otherwise specified. No ISO document has been found to be compatible.
HISTORICAL
2000-07-19
Standard
J1283_200007
This SAE Standard defines the requirements for a plug and receptacle used in an auxiliary starting system. The connector facilitates the application of supplemental electrical power for starting or charging a machine from another machine or suitable external source. This system provides: proper polarity during connector mating, secure electrical connections, and standard circuit color coding. Purpose This document establishes the connector interface dimensions and performance requirements for the electrical plug and receptacle system and its component parts.
HISTORICAL
2008-05-30
Standard
J1283_200805
This SAE Standard defines the requirements for a plug and receptacle used in an auxiliary starting system. The connector facilitates the application of supplemental electrical power for starting or charging a machine from another machine or suitable external source. This system provides: proper polarity during connector mating, secure electrical connections, and standard circuit color coding. Purpose This document establishes the connector interface dimensions and performance requirements for the electrical plug and receptacle system and its component parts.
CURRENT
2011-12-06
Standard
J1283_201112
This SAE Standard defines the requirements for a plug and receptacle used in an auxiliary starting system. The connector facilitates the application of supplemental electrical power for starting or charging a machine from another machine or suitable external source. This system provides: proper polarity during connector mating, secure electrical connections, and standard circuit color coding.
HISTORICAL
1980-06-01
Standard
J1283_198006
This SAE Standard defines the requirements for a plug and receptacle used in an auxiliary starting system. The connector facilitates the application of supplemental electrical power for starting or charging a machine from another machine or suitable external source. This system provides: proper polarity during connector mating, secure electrical connections, and standard circuit color coding. Purpose This document establishes the connector interface dimensions and performance requirements for the electrical plug and receptacle system and its component parts.
HISTORICAL
1986-03-01
Standard
J1283_198603
This SAE Standard defines the requirements for a plug and receptacle used in an auxiliary starting system. The connector facilitates the application of supplemental electrical power for starting or charging a machine from another machine or suitable external source. This system provides: proper polarity during connector mating, secure electrical connections, and standard circuit color coding. Purpose This document establishes the connector interface dimensions and performance requirements for the electrical plug and receptacle system and its component parts.
CURRENT
2003-06-17
Standard
J821_200306
This SAE Recommended Practice applies to off-road, self-propelled work machines defined in SAE J1116 JUN81.
HISTORICAL
1985-05-01
Standard
J821_198505
This SAE Recommended Practice applies to off-road, self-propelled work machines defined in SAE J1116 JUN81. Purpose This document is intended as a guide in establishing recommended material specifications and identification of the on-board electrical wiring systems for construction, agricultural, and off-road machines.
CURRENT
2013-01-18
Standard
J1811_201301
This SAE Standard is intended for light and heavy-duty on-highway trucks and their trailers; and off- road machinery applications as described in SAE J1116. The terminals described in this document are primarily used to connect batteries, cranking motors, solenoids, magnetic switches, and master disconnect switches and power cable assemblies.
HISTORICAL
2007-11-16
Standard
J1811_200711
This SAE Standard is intended for light and heavy-duty on-highway trucks and their trailers; and off-road machinery applications as described in SAE J1116. The terminals described in this document are primarily used to connect batteries, cranking motors, solenoids, magnetic switches, and master disconnect switches and power cable assemblies.
HISTORICAL
2002-10-31
Standard
J1811_200210
This SAE Standard is intended for light and heavy-duty on-highway trucks and their trailers; and off-road machinery applications as described in SAE J1116. The terminals described in this document are primarily used to connect batteries, cranking motors, solenoids, magnetic switches, and master disconnect switches and power cable assemblies.
HISTORICAL
2002-10-31
Standard
J1908_200210
This SAE Standard outlines general procedures for the grounding of electrical components in 12- and 24-V systems, intended for light and heavy-duty on-highway trucks and their trailers; and off-road machinery applications as described in SAE J1116.
HISTORICAL
2007-11-16
Standard
J1908_200711
This SAE Standard outlines general procedures for the grounding of electrical components in 12- and 24-V systems, intended for light and heavy-duty on-highway trucks and their trailers; and off-road machinery applications as described in SAE J1116.
CURRENT
2013-02-21
Standard
J1908_201302
This SAE Standard outlines general procedures for the grounding of electrical components in 12- and 24-V systems, intended for light and heavy-duty on-highway trucks and their trailers; and off-road machinery applications as described in SAE J1116.
HISTORICAL
2010-05-11
Standard
J1614_201005
This SAE Standard specifies requirements and design guidelines for electrical wiring systems of less than 50 V and cable diameters from 0.8 to 19 mm2 used on construction, agricultural, and general purpose industrial categories of off-road self-propelled work machines as defined in SAE J1116.
CURRENT
2012-09-13
Standard
J1614_201209
This SAE Standard specifies requirements and design guidelines for electrical wiring systems of less than 50 V and cable diameters from 0.35 to 19 mm2 used on off-road, self-propelled earthmoving machines as defined in SAE J1116 and agricultural tractors as defined in ASAE S390.
HISTORICAL
2008-01-15
Standard
J1614_200801
This SAE Standard specifies requirements and design guidelines for electrical wiring systems of less than 50 V and cable diameters from 0.8 to 19 mm2 used on construction, agricultural, and general purpose industrial categories of off-road self-propelled work machines as defined in SAE J1116.
HISTORICAL
2007-05-07
Standard
J2030_200705
This SAE Standard encompasses connectors between two cables or between a cable and an electrical component and focuses on the connectors external to the electrical component. This document provides environmental test requirements and acceptance criteria for the application of connectors for direct current electrical systems of 50 V or less in the majority of heavy-duty applications typically used in off-highway machinery. Severe applications may require higher test levels, or field-testing on the intended application.
HISTORICAL
2002-12-13
Standard
J2030_200212
This SAE Standard encompasses connectors between two cables or between a cable and an electrical component and focuses on the connectors external to the electrical component. This document provides environmental test requirements and acceptance criteria for the application of connectors for direct current electrical systems of 50 V or less in the majority of heavy-duty applications typically used in off-highway machinery. Severe applications may require higher test levels, or field-testing on the intended application.
CURRENT
2015-06-04
Standard
J2030_201506
This SAE Standard encompasses connectors between two cables or between a cable and an electrical component and focuses on the connectors external to the electrical component. This document provides environmental test requirements and acceptance criteria for the application of connectors for direct current electrical systems of 50 V or less in the majority of heavy-duty applications typically used in off-highway machinery. Severe applications can require higher test levels, or field-testing on the intended application.
HISTORICAL
2009-06-18
Standard
J2030_200906
This SAE Standard encompasses connectors between two cables or between a cable and an electrical component and focuses on the connectors external to the electrical component. This document provides environmental test requirements and acceptance criteria for the application of connectors for direct current electrical systems of 50 V or less in the majority of heavy-duty applications typically used in off-highway machinery. Severe applications may require higher test levels, or field-testing on the intended application.
Viewing 1 to 29 of 29