CURRENT
1993-06-14
Standard
J1533_199306
This SAE Recommended Practice establishes a uniform test procedure for determining performance levels of operator enclosure panel type air filters on off-road, self-propelled work machines used in construction, general-purpose industrial, agriculture, and forestry as defined in SAE J1116 and equipped with an operator enclosure with a powered fresh air system.
2013-10-01
WIP Standard
J1533
This SAE Recommended Practice establishes a uniform test procedure for determining performance levels of operator enclosure panel type air filters on off-road, self-propelled work machines used in construction, general-purpose industrial, agriculture, and forestry as defined in SAE J1116 and equipped with an operator enclosure with a powered fresh air system.
HISTORICAL
1996-08-01
Standard
J1535_199608
This SAE Standard establishes uniform test procedures for the defrosting systems of off-road, self-propelled work machines used in construction, general purpose industrial, agricultural, forestry, and specialized mining machinery categories as identified in SAE J1116, JUN86. It includes tests that can be conducted with uniform test equipment in commercially available laboratory facilities, as well as in an appropriate outdoor environment.
CURRENT
2014-10-24
Standard
J1535_201410
This SAE Standard establishes uniform test procedures for the defrosting systems of off-road, self-propelled work machines used in construction, general purpose industrial, agricultural, and forestry machinery as referenced in table one of this document. It includes tests that can be conducted with uniform test equipment in commercially available laboratory facilities, as well as in an appropriate outdoor environment.
2014-09-16
WIP Standard
J3078/2
J3078/2 specifies a uniform test method to determine performance levels of operator enclosure panel-type air filters used to filter the air entering an earth-moving machine operator enclosure with a powered fresh air system.
2014-09-16
WIP Standard
J3078/3
J3078/3 specifies a test method which will provide for uniform measurement of the maximum pressurization inside an operator enclosure of an earth-moving machine when equipped with a pressurization system.
2014-09-16
WIP Standard
J3078/4
J3078/4 specifies a uniform test method for measuring the contribution to operator environmental temperature provided by a heating, ventilating and air conditioning system operating in a specific ambient environment. The method might not determine the complete climatic environment of the operator since this is also affected by heat load from sources other than those on the machine, for example solar heating. J3708/6 is to be used in conjunction with J3078/4 to determine more accurately the complete heat loading on the operator enclosure. Minimum performance levels for the machine’s operator enclosure heating, ventilating and air conditioning systems are established in J3708/4.
2014-09-16
WIP Standard
J3078/5
J3078/5 specifies a test method to determine the performance of windscreen defrosting systems of earth-moving machinery, fitted with an operator enclosure and a device for defrosting the windscreen. It includes tests that can be conducted with test equipment in commercially available laboratory facilities, as well as in an appropriate outdoor environment.
CURRENT
2015-10-08
Standard
J3078/6_201510
SAE J3078/6 specifies a test method for simulating solar heating in the laboratory and measuring the radiant heat energy from a natural or simulated source. It is applicable to Off-Road Self-Propelled Work Machines as defined in SAE J1116 and Agricultural Tractors as defined in ANSI/ASAE S390.
2016-09-12
WIP Standard
J3126
This recommended practice provides technicians with safe and efficient techniques and general equipment recommendations for servicing Mobile Air Conditioning (MAC) systems in heavy duty and off-highway work machines. Presently, R-134a is the only approved refrigerant for use in mobile heavy duty and off-highway equipment and therefore this document primarily covers the servicing of R-134a systems. Since the technician may encounter other refrigerants a brief explanation on the identification safe handling of each refrigerant will be introduced.
HISTORICAL
1995-07-01
Standard
J1559_199507
This SAE Recommended Practice is applicable to off-road, self-propelled work machines from Section 1 to 5 of SAE J1116 when equipped with an operator enclosure system. This document provides a procedure for applying a simulated solar load while performing A/C tests in laboratory and determining the radiant heat energy affecting an operator enclosure system by an artificial light source or a natural solar load.
CURRENT
1985-03-01
Standard
J169_198503
The purpose of this document is to establish air conditioning design guidelines that will apply to most systems rather than the specific design of any particular system. Operating conditions and characteristics of the equipment will determine the design of any successful system, and since these characteristics and conditions vary greatly from one application to another, the designer must determine the goals expected to be reached under the conditions encountered. To determine the capacity of such items as blowers, condenser fans, condenser coils, evaporator coils, filters, compressors, etc., will require the adherence to several guidelines, some of which are outlined in the following paragraphs.
2013-09-30
WIP Standard
J169
The purpose of this document is to establish air conditioning design guidelines that will apply to most systems rather than the specific design of any particular system. Operating conditions and characteristics of the equipment will determine the design of any successful system, and since these characteristics and conditions vary greatly from one application to another, the designer must determine the goals expected to be reached under the conditions encountered. To determine the capacity of such items as blowers, condenser fans, condenser coils, evaporator coils, filters, compressors, etc., will require the adherence to several guidelines, some of which are outlined in this document.
HISTORICAL
1976-04-01
Standard
J1129_197604
The purpose of this Information Report is to establish minimum performance levels in the operator's environment for heated, ventilated, and air- conditioned construction and industrial equipment cabs. Also established are heating and air-conditioning test procedures for determining operator environment temperature, humidity, and pressurization. Note: The subject of noise is not treated in this information Report. This Information Report establishes the minimum performance levels in the operator's environment: Minimum cab pressurization and ventilation levels under all conditions of heating, air conditioning, and ventilation. Maximum humidity and minimum temperature differential under air conditioning operation. minimum temperature differential under heater operation. The report also establishes uniform test procedures for determining minimum performance levels, as defined under 2.1.1- 2.1.3, under Heater and Air conditioner operation.
CURRENT
1987-01-30
Standard
J1129_198701
The purpose of this Information Report is to establish minimum performance levels in the operator's environment for heated, ventilated, and air- conditioned construction and industrial equipment cabs. Also established are heating and air-conditioning test procedures for determining operator environment temperature, humidity, and pressurization. Note: The subject of noise is not treated in this information Report. This Information Report establishes the minimum performance levels in the operator's environment: Minimum cab pressurization and ventilation levels under all conditions of heating, air conditioning, and ventilation. Maximum humidity and minimum temperature differential under air conditioning operation. minimum temperature differential under heater operation. The report also establishes uniform test procedures for determining minimum performance levels, as defined under 2.1.1- 2.1.3, under Heater and Air conditioner operation.
2014-09-16
WIP Standard
J3078/1
J3078 provides test methods and criteria for the evaluation of the operator enclosure environment in Off-Road Self-Propelled Work Machines as defined in J1116 and Agricultural Tractors as defined in ANSI/ASAE S390 and consists of the following parts: Part 1: Terms and definitions Part 2: Air filter element test method Part 3: Pressurization test method Part 4: Heating, ventilating and air conditioning (HVAC) test method and performance Part 5: Windscreen defrosting system test method Part 6: Determination of effect of solar heating J3078/1 consists of the terms and definitions which are used in the other parts of J3708.
2012-10-17
WIP Standard
J3023
The purpose of this document is to establish guidelines for determining the critical refrigerant charge for off-road, self-propelled work machines, general purpose industrial, agricultural, forestry, and specialized mining machinery. It will develop a minimum to maximum refrigerant charge range in which the HVAC system can maintain proper operation. Operating conditions and characteristics of the equipment will influence the optimum charge. Since these conditions and characteristics vary greatly from one application to another, careful consideration should be taken to determine the optimum refrigerant charge for the HVAC system.
CURRENT
2004-09-09
Standard
J1503_200409
This SAE Standard applies to off-road, self-propelled work machines used in earth moving, agriculture, and forestry as defined in SAE J1116, and establishes the following minimum performance levels in the operator's environment for the seated position:
HISTORICAL
1995-08-01
Standard
J1503_199508
This SAE Standard applies to off-road, self-propelled work machines used in construction, general-purpose industrial, agricultural, forestry, and specialized mining machinery as defined in SAE J1116 JUN86, and establishes the following minimum performance levels in the operator's environment for the seated position: Minimum operator enclosure pressurization and ventilation levels in the operator's environment for the seated position. Maximum temperature differential under air conditioning operation. Minimum temperature differential under heater operation.
CURRENT
1987-05-01
Standard
J153_198705
These general operator precautions apply to off-road work machines as defined in SAE J1116, JUN85, Categories one, two, four and five and agricultural tractors in Category three. These should not be considered as all inclusive for all specific uses and unique features of each particular machine. Other more specific operator precautions not mentioned herein should be covered by users of this recommended practice for each particular machine application.
2013-10-02
WIP Standard
J153
These general operator precautions apply to off-road work machines as defined in SAE J1116, and Agricultural Tractors as defined in ANSI/ASAE S390, Nov 2004. These should not be considered as all inclusive for all specific uses and unique features of each particular machine. Other more specific operator precautions not mentioned herein should be covered by users of this recommended practice for each particular machine application.