Aircraft Lightning Zoning

1999-12-01
HISTORICAL
ARP5414
This SAE Aerospace Recommended Practice (ARP) defines lightning strike zones and provides guidelines for locating them on particular aircraft, together with examples. The zone definitions and location guidelines described herein are applicable to Parts 23, 25, 27, and 29 aircraft. The zone location guidelines and examples are representative of in-flight lightning exposures.
Standard

Aircraft Lightning Environment and Related Test Waveforms

2005-02-21
HISTORICAL
ARP5412A
The environment and test waveforms defined in this SAE Aerospace Recommended Practice (ARP) account for the best lightning data and analysis currently available. The quantified environment and levels herein represent the minimum currently required by certifying authorities, consistent with the approach applied in related lightning documents. Lightning, like any natural phenomenon, is probabilistic in nature. Levels and waveforms vary considerably from one flash to the next. These standardized voltage and current waveforms have been derived to represent the lightning environment, and are used to assess the direct effects of lightning on aircraft. The standardized external current waveforms have in turn been used to derive standardized transient voltage and current waveforms which can be expected to appear on the cable bundles and at equipment interfaces.
Standard

Aircraft Lightning Environment and Related Test Waveforms

2013-01-11
CURRENT
ARP5412B
The environment and test waveforms defined in this SAE Aerospace Recommended Practice (ARP) account for the best lightning data and analysis currently available. The quantified environment and levels herein represent the minimum currently required by certifying authorities, consistent with the approach applied in related lightning documents. Lightning, like other weather phenomenon, is probabilistic in nature. Levels and waveforms vary considerably from one flash to the next. Within this document, standardized voltage and current waveforms have been derived to represent the lightning environment external to an aircraft. These standardized waveforms are used to assess the effects of lightning on aircraft. The standardized external current waveforms have in turn been used to derive standardized transient voltage and current test waveforms that can be expected to appear on cable bundles and at equipment interfaces within an aircraft.
Standard

Aircraft Lightning Environment and Related Test Waveforms

1999-11-01
HISTORICAL
ARP5412
The environment and test waveforms defined in this SAE Aerospace Recommended Practice (ARP) account for the best lightning data and analysis currently available. The quantified environment and levels herein represent the minimum currently required by certifying authorities, consistent with the approach applied in related lightning documents. Lightning, like any natural phenomenon, is probabilistic in nature. Levels and waveforms vary considerably from one flash to the next. These standardized voltage and current waveforms have been derived to represent the lightning environment, and are used to assess the direct effects of lightning on aircraft. The standardized external current waveforms have in turn been used to derive standardized transient voltage and current waveforms which can be expected to appear on the cable bundles and at equipment interfaces.