Recovery and Recycle Equipment for Mobile Automotive Air-Conditioning Systems

1999-02-01
HISTORICAL
J1990_199902
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recycling equipment. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) air-conditioning (A/C) systems. Systems used on mobile vehicles for refrigerating cargo that have hermetically sealed systems are not covered in this document. The equipment in this document is intended for use with refrigerant that has been directly removed from, and intended to be returned to, a mobile A/C system. Should other revisions due to operational or technical requirements occur, this document may be amended.
Standard

EXTRACTION AND RECYCLE EQUIPMENT FOR MOBILE AUTOMOTIVE AIR-CONDITIONING SYSTEMS

1989-10-01
HISTORICAL
J1990_198910
The purpose of this document is to provide equipment specifications for CFC-12 (R-12) recycling and/or recovery, and recharging systems. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 systems. Systems used on mobile vehicles for refrigerated cargo that have hermetically sealed systems are not covered in this document.
Standard

EXTRACTION AND RECYCLE EQUIPMENT FOR MOBILE AUTOMOTIVE AIR-CONDITIONING SYSTEMS

1992-03-01
HISTORICAL
J1990_199203
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recycling equipment. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 air-conditioning systems. Systems used on mobile vehicles for refrigerated cargo that have hermetically sealed systems are not covered in this document. The equipment in this document is intended for use with refrigerant that has been directly removed from, and intended to be returned to, a mobile air-conditioning system. Should other revisions due to operational or technical requirements occur, this document may be amended.
Standard

CFC-12 (R-12) EXTRACTION EQUIPMENT FOR MOBILE AUTOMOTIVE AIR-CONDITIONING SYSTEMS

1992-06-01
HISTORICAL
J2209_199206
The purpose of this SAE Recommended Practice is to provide equipment specifications for CFC-12 (R-12) recovery for return to a refrigerant reclamation facility that will process it to ARI standard 700-88 as a minimum (Air Conditioning and Refrigerant Institute). It is not acceptable that the refrigerant removed from a mobile air-conditioning system, with this equipment, be directly returned to a mobile air-conditioning system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar R-12 systems.
Standard

ALTERNATE REFRIGERANT CONSISTENCY CRITERIA FOR USE IN MOBILE AIR CONDITIONING SYSTEMS

1993-06-01
HISTORICAL
J1658_199306
This SAE Recommended Practice applies to refrigerant blends (multicomponent refrigerants) intended for use as retrofit refrigerants to replace CFC-12 (R12) in mobile air conditioning systems. Since the composition of non-azeotropic refrigerant mixtures changes as refrigerant is lost, either through the vapor phase or the liquid phase, the method of charging air conditioning systems is important. The purpose of this document is to determine the proper refrigerant phase, liquid or vapor, for system charging by relating system performance changes to the charging method. This document is complete only when combined with the requirements of SAE J1657.
Standard

SERVICE HOSE FOR AUTOMOTIVE AIR CONDITIONING

1992-06-02
HISTORICAL
J2196_199206
This SAE Standard covers reinforced rubber, reinforced thermoplastic, or otherwise constructed hose, or hose assemblies, intended for conducting liquid and gaseous refrigerants for service connections from mobile air-conditioning systems to service equipment such as a manifold gauge set and vacuum pumps or for use internally, in charging stations or service equipment intended for use in servicing mobile air-conditioning systems.
Standard

SERVICE HOSE FOR AUTOMOTIVE AIR CONDITIONING

1997-03-01
HISTORICAL
J2196_199703
This SAE Standard covers reinforced rubber, reinforced thermoplastic, or otherwise constructed hose, or hose assemblies, intended for conducting liquid and gaseous refrigerants for service connections from mobile air conditioning systems to service equipment such as a manifold gauge set and vacuum pumps or for use internally, in charging stations or service equipment intended for use in servicing mobile air-conditioning systems.
Standard

Passenger Car Windshield Defrosting Systems

2003-07-09
HISTORICAL
J902_200307
This SAE Recommended Practice provides a test procedure and performance guideline for evaluating passenger vehicle windshield defrosting systems. It is limited to results of tests that can be conducted on uniform test equipment in commercially available laboratory facilities. The current engineering practice prescribes that for laboratory evaluation of defroster systems, a known quantity of water shall be sprayed on the windshield to form an ice coating and then melted by the defroster under specific vehicle operating conditions. The procedure provides uniform and repeatable laboratory test results, even though under actual conditions such a coating would be removed by scraping before driving the vehicle. The performance obtained, therefore, does not directly relate to actual driving conditions, but serves as a laboratory performance indicator for comparing test results within or between systems.
Standard

Motor Vehicle Heater Test Procedure

1998-11-05
HISTORICAL
J638_199811
This SAE Recommended Practice, limited to liquid coolant systems, establishes uniform vehicle heater test procedures. Both laboratory and complete vehicle tests are specified in this document. Required test equipment, facilities, and definitions are included.
Standard

MOTOR VEHICLE HEATER TEST PROCEDURE

1982-06-01
HISTORICAL
J638_198206
This SAE Recommended Practice, limited to liquid coolant systems, establishes uniform vehicle heater test procedures. Both laboratory and complete vehicle tests are specified in this recommended practice. Required test equipment, facilities and definitions are included. NOTE: Defrosting and defogging procedures and requirements can be found in SAE J902b, J381, J382, and J953.
Standard

Safety Standards for Motor Vehicle Refrigerant Vapor Compression Systems

2011-02-04
HISTORICAL
J639_201102
This SAE Standard applies to refrigerant vapor compression systems that provide cooling and/or heating for passenger cars, light trucks and commercial vehicles (on and off road) that use automotive type mobile air conditioning (MAC) systems. Large trucks, buses and other vehicles that do not use typical automotive a/c systems or use refrigerants not listed in this document are not covered by this standard. This standard covers any vehicle with a MAC system using a belt or electric motor driven compressor. This document provides standards for design, assembly, test and service of MAC systems to minimize environmental, health and safety impacts. Also included are cautionary statements for the service industry to alert technicians to the inadvisability and possible health or safety effects associated with venting refrigerant during service. It is not intended to restrict the use, or further development, of other types of refrigeration systems for mobile air conditioning applications.
Standard

R134a Mobile Air Conditioning System Leakage Chart

2005-06-08
HISTORICAL
J2727_200506
Current industry standards do not exist for determining refrigerant emissions from mobile air conditioning systems. Test procedures are not common between production component suppliers in establishing leakage values. This “System Leakage Chart” has been developed from industry experience of expected refrigerant leakage gains from system design resulting from technology changes. It provides a rating value of various technologies that are currently available. The “Leakage Chart” can be expanded as new technologies are offered and/or developed. This document provides the information to develop an Excel file template “Leakage Chart” for making system analysis. It is not the intent of this Standard to define the refrigerant emissions from a mobile air conditioning system. It is to only define a system rating based upon the technology used.
Standard

HFC-134a Mobile Air Conditioning System Emission Chart

2007-07-12
HISTORICAL
J2727_200707
The original SAE J2727 “Leakage Chart” provided a rating system for comparing mobile A/C systems and was not intended to define mobile A/C system refrigerant leakage. It had been developed from industry experience of expected system refrigerant leakage based upon currently available technologies. The new “System Emissions Chart” now contained in this revision is intended to serve as a means of estimating the annual refrigerant emissions rate (grams per year) from new production A/C systems equipped with specified component technologies. It provides emission values for various component technologies that are currently available, and can be expanded as new technologies are commercialized. This document provides the information to develop an Excel file template “System Emissions Chart” for system emission analysis. The new chart includes automotive compressor technologies, for conventional mobile air conditioning systems as well as fully hermetic compressors.
Standard

R134a Refrigerant Automotive Air-Conditioned Hose

2005-12-12
HISTORICAL
J2064_200512
This SAE Standard covers hose and hose assemblies intended for conducting liquid and gaseous R134a refrigerant in automotive air-conditioning systems. The hose shall be designed to minimize permeation of R134a refrigerant, contamination of the system, and to be functional over a temperature range of –30 °C to 125 °C. Specific construction details are to be agreed upon between user and supplier. A hose marked “J2064” signifies that it has been coupled, tested, and has met the requirements of SAE J2064. It is the hose assembly manufacturer’s responsibility to see that the assemblies meet the specified acceptance criteria for this specification.