Refine Your Search

Search Results

Viewing 1 to 9 of 9
Technical Paper

The Influence of an On Line Oil Recycler on Oil Quality with Oil Age from a Low Emission DI Diesel Engine

2003-10-27
2003-01-3226
A method of cleaning lubricating oil on line was investigated using a fine bypass particulate filter followed by an infrared heater, to remove water and light diesel fractions in the oil. The impact of this oil recycler with 1 micron fine bypass filter on oil quality was investigated over a 72 hour oil age. Comparisons tests were undertaken without and with the recycler on a Euro 2 Perkins Phaser 180Ti 6 cylinder 6 litre turbo-charged inter-cooled DI diesel engine. The tests were carried out at 2000rpm and 100kW with 473 Nm load. A stop start test cycle was used with a cold start each time and a typical test period of 2 hours. The results showed that the oil quality in this low emission engine test was extremely good. The on line recycler achieved improvements in the oil quality. With the recycler, the carbon accumulation rate in the oil was reduced by 78%. The carbon removal rate by the recycler was 0.40 g/hr. The wear metals in the oil were significantly reduced.
Technical Paper

The Influence of an Oil Recycler on Emissions with Oil Age for a Refuse Truck Using in Service Testing

2001-03-05
2001-01-0623
A method of cleaning lubricating oil on line was investigated using a fine bypass particulate filter followed by an infra red heater. Two bypass filter sizes of 6 and 1 micron were investigated, both filter sizes were effective but the one micron filter had the greatest benefit. This was tested on two nominally identical EURO 1 emissions compliance refuse trucks, fitted with Perkins Phazer 210Ti 6 litre turbocharged intercooled engines and coded as RT320 and RT321. These vehicles had emissions characteristics that were significantly different, in spite of their similar age and total mileage. RT321 showed an apparent heavier black smoke than RT320. Comparison was made with the emissions on the same vehicles and engines with and without the on-line bypass oil recycler. Engine exhaust emissions were measured about every 400 miles. Both vehicles started the test with an oil drain and fresh lubricating oil.
Technical Paper

Improvements in Lubricating Oil Quality by an On Line Oil Recycler for a Refuse Truck Using in Service Testing

2001-03-05
2001-01-0699
A method of cleaning lubricating oil on line was investigated using a fine bypass particulate filter followed by an infra red heater. Two bypass filter sizes of 6 and 1 micron were investigated, both filter sizes were effective but the one micron filter had the greatest benefit. This was tested on two nominally identical EURO 1 emissions compliance refuse trucks, fitted with Perkins Phazer 210Ti 6 litre turbocharged intercooled engines and coded as RT320 and RT321. These vehicles had lubricating oil deterioration and emissions characteristics that were significantly different, in spite of their similar age and total mileage. RT321 showed an apparent heavier black smoke than RT320. Comparison was made with the oil quality and fuel and lubricating oil consumption on the same vehicles and engines with and without the on-line bypass oil recycler. Engine oils were sampled and analysed about every 400 miles. Both vehicles started the test with an oil drain and fresh lubricating oil.
Technical Paper

The Influence of an On Line Oil Recycler on Oil Quality from a Bus in Service Using Synthetic Oil

2001-05-07
2001-01-1969
A method of cleaning lubricating oil on line was investigated using a one micron bypass particulate filter followed by an infra-red heater, to remove water, dissolved gases and light diesel fractions in the oil. The impact of this oil recycler on oil quality was studied using synthetic oil in an on-road bus test. The bus was of Euro-1 emissions standard and equipped with a Cummins 6 cylinder 8.3 litre turbo-charged inter-cooled DI engine. Comparisons tests were undertaken with and without the oil recycler for about 28,000 miles. Oil samples were analysed about every 2000 miles. The results showed that the on line oil recycler achieved significant improvements in the oil quality. With the recycler, the TBN depletion rate was reduced by 52%, the TAN increase rate was reduced by 27% and the carbon accumulation rate in the oil was reduced by 42%. The fuel dilution was reduced by the recycler.
Technical Paper

Oil Quality with Oil Age in an IDI Diesel Passenger Car Using an On Line Lubricating Oil Recycler Under Real World Driving

2001-05-07
2001-01-1898
A method of cleaning lubricating oil on line was investigated using a fine 1 micron bypass particulate filter, followed by an infra-red heater to remove water and light diesel fractions in the oil. A Ford 1.8 litre IDI diesel passenger car was investigated under real world driving conditions. Comparison was made with the oil quality without the recycler. All the tests were carried out on the same vehicle over 7000 miles with and without the recycler. The results showed that the on line oil recycler cleaning system reduced the rate of reduction of TBN and the rate of increase of TAN by 54% and 50% respectively. The reduction in the rate of carbon accumulation in the oil was 42%. There was also a reduction in fuel dilution. All the wear metals in the oil were greatly reduced by the recycler, the iron was reduced by 76%, the lead was reduced by 85% and the aluminum was totally removed.
Technical Paper

Effects of an on Line Bypass Oil Recycler on Emissions with Oil Age for a Bus Using in Service Testing

2001-09-24
2001-01-3677
A method of cleaning lubricating oil on line was investigated using a fine bypass particulate filter followed by an infra red heater. Two bypass filter sizes of 6 and 1 micron were investigated, both filter sizes were effective but the one micron filter had the greatest benefit. This was tested on two nominally identical EURO 2 emissions compliance single decker buses, fitted with Cummins 6 cylinder 8.3 litre turbocharged intercooled engines and coded as Bus 4063 and 4070. These vehicles had emissions characteristics that were significantly different, in spite of their similar age and total mileage. Bus 4063 showed an apparent deterioration on emissions with time while Bus 4070 showed a stabilised trend on emissions with time for their baseline tests without the recycler fitted. Comparison was made with the emissions on the same vehicles and engines with and without the on-line bypass oil recycler. Engine exhaust emissions were measured about every 2000 miles.
Technical Paper

The Influence of an On Line Heated Lubricating Oil Recycler on Emissions from an IDI Passenger Car Diesel as a Function of Oil Age

2000-03-06
2000-01-0232
A method of cleaning diesel engine lubricating oil on-line was investigated using a bypass fine particulate filter followed by an infra-red heater to remove water vapour and light diesel fractions in the oil. The impact of this oil recycler on the gaseous and particulate emissions was investigated over a 300 hour oil age period. A Ford 1.8 litre IDI passenger car diesel engine was used with engine out emission sampled every 15-20 hours. The tests were carried out at 2500rpm (52% of the maximum speed) and 12.3 kW with 47 Nm load (43% of the maximum load and 29% of the maximum power). The EGR level at this condition was 15%. A stop start test cycle was used with a cold start each time and a typical test period of 2-3 hours. The results showed that the recycler had its greatest influence on emissions for fresh oil when there was a large reduction in particulate emissions due mainly to large reductions in the ash, carbon and unburned lubricating oil fractions.
Technical Paper

The Influence of an Oil Recycler on Lubricating Oil Quality with Oil Age for a Bus Using in Service Testing

2000-03-06
2000-01-0234
A method of cleaning lubricating oil on line was investigated using a fine bypass particulate filter followed by an infra red heater, to remove water and light diesel fractions in the oil. Two bypass filter sizes of 6 and 1 micron were investigated, both filter sizes were effective but the one micron filter had the greatest benefit. This was tested on two nominally identical Euro 2 emissions compliance single decker buses, fitted with Cummins 6 cylinder 8.3 litre turbocharged intercooled engines. These vehicles had oil deterioration and emissions characteristics that were significantly different, in spite of their similar age and total mileage. Comparison was made with the oil quality on the same vehicles and engines with and without the on-line recycler. Oil samples were analysed about every 2000 miles. All tests started with an oil drain and fresh lubricating oil.
Technical Paper

Oil Quality in Diesel Engines With On Line Oil Cleaning Using a Heated Lubricating Oil Recycler

1999-03-01
1999-01-1139
SYNOPSIS A method of cleaning the oil on line was investigated using a bypass fine particulate filter followed by an infra red heater to remove water and light diesel fractions in the oil. This was tested on a range of on road vehicles and a Ford 1.8 litre IDI passenger car engine on a test bed. Comparison was made with the oil quality on the same vehicles and engines without the on-line recycler. Test times were from 200 to 1500 hours of oil ageing and some of the tests showed that the oil quality was still good after 4 times the normal oil life. The results showed that the on line oil recycler cleaning system reduced the rate of fall of the TBN and rate of increase of the TAN. There was a very significant reduction in the soot in oil and the fuel dilution. There was also a consistent reduction in all the wear metals apart from copper and a decrease in the rate of reduction of oil additives. There was also measured on the Ford IDI engine a 5% reduced fuel consumption.
X