Refine Your Search

Affiliation

Search Results

Technical Paper

The Effects of Small Seat Swiveling Angles on Occupant Responses during a Frontal Impact

2020-04-14
2020-01-0571
In highly automated vehicles (HAVs), new seat configurations may be desirable to allow occupants to perform new activities. One of the current HAV concepts is the swiveled seat layout, which might facilitate communication between occupants. The main objective of this study was to investigate the effects of seat swiveling angles on occupant kinematics and injury risk predicted by a Human Body Model (HBM) during a frontal impact. A detailed 50th percentile male HBM (GHBMC M50-O) was subjected to two frontal crash pulses in a sled setup. The model was positioned on a semi-rigid seat and restrained using a pre-inflated airbag and a three-point seatbelt. Simulations included four seat swiveling angles (0, -10, -20, and -30 degrees), three occupant positions (Sedan driver, large VAN driver or Laptop user), two airbag initial locations (nominal or matching the head Y location), and the inclusion of lateral supports on the seat pan.
Technical Paper

The Programmed Restraint System - A Lesson from Accidentology

1997-11-12
973333
Accident studies show that frontal collisions, both as regards the number of people killed and those seriously-injured, are by far the type of crash with the most serious consequences. In order to improve this situation, it is necessary to ensure that the means used to restrain occupants work as efficiently as possible, whilst preserving the occupant compartment and thus by eliminating intrusion on the occupant restrained by seat-belts and pretensioners. In frontal collisions where vehicle intrusion is minor, the main lesions caused to occupantss are thoracic, mainly rib fractures resulting from the seat-belt. In collisions where intrusion is substantial, the lower members are particularly vulnerable. In the coming years, we will see developments which include more solidly-built cars, as offset crash test procedures are widely used to evaluate the passive safety of production vehicles.
Technical Paper

Update of the WorldSID 50th Male Pelvic Injury Criterion and Risk Curve

2018-04-03
2018-01-0539
Petit et al. 2015 and Lebarbé et al. 2016 reported on two studies where the injury mechanism and threshold of the sacroiliac joint were investigated in two slightly oblique crash test conditions from 18 Post Mortem Human Subjects (PMHS) tests. They concluded that the sacroiliac joint fractures were associated with pubic rami fractures. These latter being reported to occur first in the time history. Therefore it was recommended not to define a criterion specific for the sacroiliac joint. In 2012, injury risk curves were published for the WorldSID dummy by Petitjean et al. For the pelvis, dummy and PMHS paired tests from six configurations were used (n = 55). All of these configurations were pure lateral impacts. In addition, the sacroiliac joint and femur neck loads were not recorded, and the dummy used was the first production version (WorldSID revision 1). Since that time, the WorldSID was updated several times, including changes in the pelvis area.
Technical Paper

Dynamic Biomechanical Dorsiflexion Responses and Tolerances of the Ankle Joint Complex

1997-11-12
973330
This paper presents comprehensive dorsiflexion responses and tolerances obtained from two types of dynamic tests on whole cadavers conducted at the Renault/PSA Laboratory of Accidentology and Biomechanics (LAB): sled tests and sub-system tests. In all the experiments (on whole cadavers), forces and moments within the ankle joint were accurately measured by means of a custom-designed 6-axis load cell implanted in the tibia, leaving all surrounding musculature intact. The results derived from both the sled tests and the subsystem tests are very similar. Moment-rotation curves are provided for the ankle joint. The force in the Achilles tendon which is not directly measured is calculated using the forces applied to the foot and the forces measured in the tibia.
Technical Paper

Influence of Test Conditions on Protection Criteria in Side Impact

1996-11-01
962420
Numerous cadaver tests have been performed in the past to define the behaviour and tolerance of the thorax under side impact conditions. To take into account the various test conditions and measurements techniques or parameters, a lumped parameter model is used to reproduce these tests and thus to compute the protection criteria in the same way. The correlation between the calculated criteria and the observed injuries is then analysed as a basis for discussion of their consistency and relevance. The second part of the paper deals with the transposition of tolerance criteria to the Eurosid 1 dummy, using simulation tests under different conditions (impactor test, free-fall test, imposed velocity). The results show that this transposition depends on the test conditions, because of the limited biofidelity of the Eurosid 1 dummy.
Technical Paper

Biomechanical Response and Physical Properties of the Leg, Foot, and Ankle

1996-11-01
962424
The anatomical dimensions, inertial properties, and mechanical responses of cadaver leg, foot, and ankle specimens were evaluated relative to those of human volunteers and current anthropometric test devices. Dummy designs tested included the Hybrid III, Hybrid III with soft joint stops, ALEX I, and the GM/FTSS lower limbs. Static and dynamic tests of the leg, foot, and ankle were conducted at the laboratories of the Renault Biomedical Research Department and the University of Virginia. The inertial and geometric properties of the dummy lower limbs were measured and compared with cadaver properties and published volunteer values. Compression tests of the leg were performed using static and dynamic loading to determine compliance of the foot and ankle. Quasi-static rotational properties for dorsiflexion and inversion/eversion motion were obtained for the dummy, cadaver, and volunteer joints of the hindfoot.
Technical Paper

Neck Injury Criteria for Children from Real Crash Reconstructions

1993-11-01
933103
In view of the lack of data concerning child protection, an accidentological and experimental work was engaged. The goal of this international research involving experts from seven countries was two-fold: In one hand, to establish protection principles, gathering and analysing real crashes involving restrained children. In the other hand, to identify and to quantify injury mechanisms in order to increase knowledge on child tolerances. To realize this second part, real crash reconstructions were performed, in order to correlate observed injuries with recorded parameters on dummies. This paper mainly presents four real crashes with the corresponding reconstructions. A special analysis of injury mechanisms in relation with their respective pertinent parameters is then proposed.
Technical Paper

Assessment of Several THOR Thoracic Injury Criteria based on a New Post Mortem Human Subject Test Series and Recommendations

2020-03-31
2019-22-0012
Several studies, available in the literature, were conducted to establish the most relevant criterion for predicting the thoracic injury risk on the THOR dummy. The criteria, such as the maximum deflection or a combination of parameters including the difference between the chest right and left deflections, were all developed based on given samples of Post Mortem Human Subject (PMHS). However, they were not validated against independent data and they are not always consistent with the observations from field data analysis. For this reason, 8 additional PMHS and matching THOR tests were carried out to assess the ability of the criteria to predict risks. Accident investigations showed that a reduction of the belt loads reduces the risk of rib fractures. Two configurations with different levels of force limitation were therefore chosen. A configuration representing an average European vehicle was chosen as a reference.
Technical Paper

Reference PMHS Sled Tests to Assess Submarining of the Small Female

2018-11-12
2018-22-0003
In the last decade, extensive efforts have been made to understand the physics of submarining and its consequences in terms of abdominal injuries. For that purpose, 27 Post Mortem Human Subject (PMHS) tests were performed in well controlled conditions on a sled and response corridors were provided to assess the biofidelity of dummies or human body models. All these efforts were based on the 50th percentile male. In parallel, efforts were initiated to transfer the understanding of submarining and the prediction criteria to the THOR dummies. Both the biofidelity targets and the criteria were scaled down from the 50th percentile male to the 5th percentile THOR female. The objective of this project was to run a set of reference PMHS tests in order to check the biofidelity of the THOR F05 in terms of submarining. Three series of tests were performed on nine PMHS, the first one was designed to avoid submarining, the second and third ones were designed to result in submarining.
Technical Paper

Relation Between Sacroilium and Other Pelvic Fractures Based on Real-World Automotive Accidents

2018-11-12
2018-22-0010
The study firstly aimed at looking whether sacroilium (SI) fractures could be sustained as unique pelvic injuries in side impact real world automotive accidents. Secondarily, the sacroilium fractures observed in conjunction with other pelvic fractures were analyzed to investigate the existence of injury association patterns. Two real world accident databases were searched for SI fractures. The occupants selected were front car passengers older than 16, involved in side, oblique or frontal impact, with AIS2+ pelvic injuries. In frontal impact, only the belted occupants were selected. The cases were sorted by the principal direction of force (dof) and the type of pelvic injury, namely SI, pubic rami, iliac wing, acetabulum, pubic symphysis, and sacrum injuries. The relation between SI and pubic rami injuries were investigated first. The first database is an accident database composed of cases collected in France by car manufacturers over a period of approximately 40 years.
Technical Paper

THOR-05F Response in Sled Tests Inducing Submarining and Comparison with PMHS Response Corridors

2022-05-20
2021-22-0005
The Test Device for Human Occupant Restraint (THOR) is an advanced crash test dummy designed for frontal impact. Originally released in a 50th percentile male version (THOR-50M), a female 5th version (THOR-05F) was prototyped in 2017 (Wang et al., 2017) and compared with biofidelity sub-system tests (Wang et al., 2018). The same year, Trosseille et al. (2018) published response corridors using nine 5th percentile female Post Mortem Human Subjects (PMHS) tested in three sled configurations, including both submarining and non-submarining cases. The goal of this paper is to provide an initial evaluation of the THOR-05F biofidelity in a full-scale sled test, by comparing its response with the PMHS corridors published by Trosseille et al. (2018). Significant similarities between PMHS and THOR-05F were observed: as in Trosseille et al. (2018), the THOR-05F did not submarine in configuration 1, and submarined in configurations 2 and 3.
Technical Paper

Comparison of the Thor, Hybrid Iii and Cadaver Lower Leg Dynamic Responses in Dorsiflexion

1999-10-10
99SC10
As of toady, statutory crash test dummies take neither bracing nor passive muscular effect into account in the lower limb area. The influence of the lower extremity musculature is however arising as a major concern for the study of front seat occupant protection. The lower extremity prototype of the THOR dummy, including a model of the human plantarflexion actuator passive response, was tested in dynamic dorsiflexion. A dynamic test series was performed on Thor-Lx under test conditions similar to those used by Portier et al., 1996, on cadavers and Hybrid III dummy. The test setup imposed a dynamic dorsiflexion to the foot by means of a load exerted under the ball of the foot with no impact velocity. The Thor-Lx and Hill responses are compared to cadaver responses. It is important to note that as of today there are no data available to demonstrate that the passive resistance of the cadaver is equivalent to resistance of a tensed human.
Technical Paper

Investigations on the Belt-to-Pelvis Interaction in Case of Submarining

2006-11-06
2006-22-0003
This study focuses on the phenomenon of lap belt slip on the iliac spines of the pelvis, commonly named “submarining ”. The first objective was to compare the interaction between the pelvis and the lap belt for both dummies and Post Mortem Human Subjects (PMHS). The second objective was to identify parameters influencing the lap belt hooking by the pelvis. For that purpose, a hydraulic test device was developed in order to impose the tension and kinematics of the lap belt such that they mimic what occurs in frontal car crashes. The pelvis was firmly fixed on the frame of this sub-system test-rig, while the belt anchorages were mobile. Fourteen tests on four Post-Mortem Human Subjects (PMHS) and fifteen tests on the THOR NT, Hybrid III 50th and Hybrid III 95th percentile dummies were carried out. The belt tension was kept constant while a dynamic rotation was imposed on the belt anchorages.
Technical Paper

Side Impact: Influence of Impact Conditions and Bone Mechanical Properties on Pelvic Response Using a Fracturable Pelvis Model

2006-11-06
2006-22-0004
This study aimed at determining the influence of impact conditions and occupant mechanical properties on pelvic response in side impact. First, a fracturable pelvis model was developed and validated against dynamic tests on isolated pelvic bones and on whole cadavers. By coupling a fixed cortical bone section thickness within a single subject's pelvis and across the population with a parametric material law for the pelvic bone, this model reproduced the pelvic response and tolerance variation among individuals. Three material laws were also identified to represent fragile, medium and strong pelvic bones for the 50th percentile male. With this model, the influence of impact mass, velocity and surface shape on pelvic response was examined. Results indicated that the shape difference between four main impactors reported in the literature has little effect on the pelvic response.
Technical Paper

Assessment of the Pubic Force as a Pelvic Injury Criterion in Side Impact

2007-10-29
2007-22-0019
In the literature, injuries at the ischio or ilio pubic ramus level are reported to occur to approximately ¾ of the occupants injured at the pelvis during side impact. Assuming that the load going through the pubis was a good indicator of the ramus stress, the pubic force was widely accepted as a protection criterion for pelvic fractures on side impact dummies. However, no data regarding the actual loads going through the pubis is currently available in the literature for Post Mortem Human Subjects (PMHS) in dynamic conditions. The goal of this study was to determine pelvic biofidelity specifications in terms of load path, to evaluate the pertinence of the pubic force as a criterion, and to develop a pelvic injury risk curve as a function of the pubic force. For that purpose, a pubic load cell was developed for PMHS use, and 16 side impact tests were performed on 8 PMHS using boundary conditions similar to impactor tests and sled tests reported in the literature.
Technical Paper

Evaluation of Thoracic Deflection as an Injury Criterion for Side Impact Using a Finite Elements Thorax Model

2009-11-02
2009-22-0006
This study aims to investigate the relationship between the number of rib fractures and the thoracic deflection in side impact, and in particular its variability with respect to various loading configurations. The relevance of thoracic deflection as an injury criterion depends on the existence or not of this variability. Few studies were dedicated to this issue in the literature. First, a validation database was established, which covers different impact directions (frontal, lateral and oblique), different loading types (impactor, belt and airbag), and different injury levels (from the absence of, to presence of numerous ribs fractured). The HUMOS human body model was then modified and validated versus the database. Besides the typical validation in terms of global response, particular attention was paid to validate the model with respect to the ribcage strain profile, the occurrence of rib fractures and their locations.
Technical Paper

3D Deformation and Dynamics of the Human Cadaver Abdomen under Seatbelt Loading

2008-11-03
2008-22-0011
According to accident analysis, submarining is responsible for most of the frontal car crash AIS 3+ abdominal injuries sustained by restrained occupants. Submarining is characterized by an initial position of the lap belt on the iliac spine. During the crash, the pelvis slips under the lap belt which loads the abdomen. The order of magnitude of the abdominal deflection rate was reported by Uriot to be approximately 4 m/s. In addition, the use of active restraint devices such as pretensioners in recent cars lead to the need for the investigation of Out-Of-Position injuries. OOP is defined by an initial position of the lap belt on the abdomen instead of the pelvis resulting in a direct loading of the abdomen during pretensioning and the crash. In that case, the penetration speed of the belt into the abdomen was reported by Trosseille to be approximately 8 to 12 m/s. The aim of this study was to characterize the response of the human abdomen in submarining and OOP.
Technical Paper

Statistical Simulations to Evaluate the Methods of the Construction of Injury Risk Curves

2011-11-07
2011-22-0015
Several statistical methods are currently used to build injury risk curves in the biomechanical field. These methods include the certainty method (Mertz et al. 1996), Mertz/Weber method (Mertz and Weber 1982), logistic regression (Kuppa et al. 2003, Hosmer and Lemeshow 2000), survival analysis with Weibull distribution (Kent et al. 2004, Hosmer and Lemeshow 2000), and the consistent threshold estimate (CTE) (Nusholtz et al. 1999, Di Domenico and Nusholtz 2005). There is currently no consensus on the most accurate method to be used and no guidelines to help the user to choose the more appropriate one. Injury risk curves built for the WorldSID 50th side impact dummy with these different methods could vary significantly, depending on the sample considered (Petitjean et al. 2009). As a consequence, further investigations were needed to determine the fields of application of the different methods and to recommend the best statistical method depending on the biomechanical sample considered.
Technical Paper

Sensitivity of the WorldSID 50th and ES-2re Thoraces to Loading Configuration

2010-11-03
2010-22-0013
An ideal injury criterion should be predictive of the risk of injury across the range of loading conditions where it may be applied. The injury risk curve associated with this criterion should be applicable to all loading conditions. With respect to side impact, the injury risk curve should apply to pure lateral or oblique loading by rigid and padded walls, as well as airbags. Trosseille et al., (2009) reported that the number of fractured ribs was higher in pure lateral impact than in forward oblique interaction with an airbag. A good dummy criterion should be able to account for this difference. To evaluate various injury criteria with the WorldSID 50th and ES-2re dummies, the dummies were exposed to the same airbag loadings as the PMHS. The criteria measured in the dummy tests were paired with the rib fractures from the PMHS tests.
Technical Paper

Abdominal Twin Pressure Sensors for the Assessment of Abdominal Injuries in Q Dummies: In-Dummy Evaluation and Performance in Accident Reconstructions

2012-10-29
2012-22-0010
The Abdominal Pressure Twin Sensors (APTS) for Q3 and Q6 dummies are composed of soft polyurethane bladders filled with fluid and equipped with pressure sensors. Implanted within the abdominal insert of child dummies, they can be used to detect abdominal loading due to the belt during frontal collisions. In the present study - which is part of the EC funded CASPER project - two versions of APTS (V1 and V2) were evaluated in abdominal belt compression tests, torso flexion test (V1 only) and two series of sled tests with degraded restraint conditions. The results suggest that the two versions have similar responses, and that the pressure sensitivity to torso flexion is limited. The APTS ability to detect abdominal loading in sled tests was also confirmed, with peak pressures typically below 1 bar when the belt loaded only the pelvis and the thorax (appropriate restraint) and values above that level when the abdomen was loaded directly (inappropriate restraint).
X