Refine Your Search

Search Results

Technical Paper

Hybrid III Sternal Deflection Associated with Thoracic Injury Severities of Occupants Restrained with Force-Limiting Shoulder Belts

1991-02-01
910812
A relationship between the risk of significant thoracic injury (AIS ≥ 3) and Hybrid III dummy sternal deflection for shoulder belt loading is developed. This relationship is based on an analysis of the Association Peugeot-Renault accident data of 386 occupants who were restrained by three-point belt systems that used a shoulder belt with a force-limiting element. For 342 of these occupants, the magnitude of the shoulder belt force could be estimated with various degrees of certainty from the amount of force-limiting band ripping. Hyge sled tests were conducted with a Hybrid III dummy to reproduce the various degrees of band tearing. The resulting Hybrid III sternal deflections were correlated to the frequencies of AIS ≥ 3 thoracic injury observed for similar band tearing in the field accident data. This analysis indicates that for shoulder belt loading a Hybrid III sternal deflection of 50 mm corresponds to a 40 to 50% risk of an AIS ≥ 3 thoracic injury.
Technical Paper

Thoracic Injury Assessment of Belt Restraint Systems Based on Hybrid III Chest Compression

1991-10-01
912895
Measurement of chest compression is vital to properly assessing injury risk for restraint systems. It directly relates chest loading to the risk of serious or fatal compression injury for the vital organs protected by the rib cage. Other measures of loading such as spinal acceleration or total restraint load do not separate how much of the force is applied to the rib cage, shoulders, or lumbar and cervical spines. Hybrid III chest compression is biofidelic for blunt impact of the sternum, but is “stiff” for belt loading. In this study, an analysis was conducted of two published crash reconstruction studies involving belted occupants. This provides a basis for comparing occupant injury risks with Hybrid III chest compression in similar exposures. Results from both data sources were similar and indicate that belt loading resulting in 40 mm Hybrid III chest compression represents a 20-25% risk of an AIS≥3 thoracic injury.
Technical Paper

SID-IIs Beta+-Prototype Dummy Biomechanical Responses

1998-11-02
983151
This paper presents the results of biomechanical testing of the SID-IIs beta+-prototype dummy by the Occupant Safety Research Partnership. The purpose of this testing was to evaluate the dummy against its previously established biomechanical response corridors for its critical body regions. The response corridors were scaled from the 50th percentile adult male corridors defined in International Standards Organization Technical Report 9790 to corridors for a 5th percentile adult female, using established International Standards Organization procedures. Tests were performed for the head, neck, shoulder, thorax, abdomen and pelvis regions of the dummy. Testing included drop tests, pendulum impacts and sled tests. The biofidelity of the SID-IIs beta+-prototype was calculated using a weighted biomechanical test response procedure developed by the International Standards Organization.
Technical Paper

Brain Injury Risk Assessment of Frontal Crash Test Results

1994-03-01
941056
An objective, biomechanically based assessment is made of the risks of life-threatening brain injury of frontal crash test results. Published 15 ms HIC values for driver and right front passenger dummies of frontal barrier crash tests conducted by Transport Canada and NHTSA are analyzed using the brain injury risk curve of Prasad and Mertz. Ninety-four percent of the occupants involved in the 30 mph, frontal barrier compliance tests had risks of life-threatening brain injury less than 5 percent. Only 3 percent had risks greater than 16 percent which corresponds to 15 ms HIC > 1000. For belt restrained occupants without head contact with the interior, the risks of life-threatening brain injury were less than 2 percent. In contrast, for the more severe NCAP test condition, 27 percent of the drivers and 21 percent of the passengers had life-threatening brain injury risks greater than 16 percent.
Technical Paper

The Effect of Limiting Shoulder Belt Load with Air Bag Restraint

1995-02-01
950886
The dilemma of using a shoulder belt force limiter with a 3-point belt system is selecting a limit load that will balance the reduced risk of significant thoracic injury due to the shoulder belt loading of the chest against the increased risk of significant head injury due to the greater upper torso motion allowed by the shoulder belt load limiter. However, with the use of air bags, this dilemma is more manageable since it only occurs for non-deploy accidents where the risk of significant head injury is low even for the unbelted occupant. A study was done using a validated occupant dynamics model of the Hybrid III dummy to investigate the effects that a prescribed set of shoulder belt force limits had on head and thoracic responses for 48 and 56 km/h barrier simulations with driver air bag deployment and for threshold crash severity simulations with no air bag deployment.
Technical Paper

Thoracic Tolerance to Whole-Body Deceleration

1971-02-01
710852
A professional high diver, instrumented with accelerometers, performed sixteen dives from heights between 27-57 ft. For each dive, he executed a 3/4 turn and landed supine on a 3-ft deep mattress which consisted of pieces of low-density urethane foam encased in a nylon cover. Using FM telemetry, sagittal plane decelerations were recorded for a point either on the sternum or the forehead. Impact velocities and corresponding stopping distances for the thorax and the head were calculated from high-speed movies of the dives. For a 57-ft dive, the impact velocity of the thorax was 41 mph with a corresponding stopping distance of 34.6 in. The peak resultant deceleration of the thorax was 49.2 g with a pulse duration of 100 ms. The maximum rate of change of the deceleration of the thorax was 5900 g/s. No discomfort was experienced as a result of this impact. The maximum forehead deceleration occurred during a 47.0-ft drop and exceeded 56 g with a Gadd Severity Index greater than 465.
Technical Paper

Prediction of Thoracic Injury from Dummy Responses

1975-02-01
751151
Currently used criteria based on functions of spinal acceleration obtained from crash test dummies are shown to be invalid indicators of chest injuries in blunt frontal impacts. Cadaver impact data are analyzed; and injury is found to be a statistically significant function of chest deflection, chest depth, and cadaver age at death. Based on the resulting regression equations, injury-limiting chest deflections are recommended for various size test dummies. The recommendations apply only to test dummies that have significant thoracic biofidelity for blunt frontal impact. They are valid for environments which include signigicant blunt frontal impact. Their extension to other environments has not been validated.
Technical Paper

The Highway Safety Research Institute Dummy Compared with General Motors Biofidelity Recommendations and the Hybrid II Dummy

1974-02-01
740588
Two Highway Safety Research Institute (HSRI) dummies were tested and evaluated. Based on the analysis given, the HSI dummy should not be used for vehicle qualification testing. However, many of its components offer viable alternatives for future dummy development. The dummy was found to have inadequate biomechanical fidelity in the head, neck, and chest, although its characteristics were very promising and, as a whole, biomechanically superior to the Hybrid II. Its repeatability and reproducibility in dynamic component tests were better than the Hybrid II dummy. In particular, the HSRI friction joints were outstanding in repeatability and had a significant advantage in usability in that they do not require resetting between tests. In three-point harness and ACRS systems tests, the values of injury criteria produced by the HSRI dummy were generally lower than those obtained with the Hybrid II, especially the femur loads in the ACRS tests.
Technical Paper

Forces on the Human Body in Simulated Crashes

1965-10-20
650961
Details of a new crash simulator and preliminary results from a series of cadaver knee impact experiments were presented at the Eighth Stapp Conference. During the past year additional data concerning injury to the knee-thigh-hip complex have been obtained, and the studies have been extended to consider impact to the chest. Results to date indicate that for knee impacts against a moderately padded surface it is not possible to predict whether failure of the patella, femur or pelvis will occur first, although in these studies femoral fractures occurred most frequently. A force of 1400 lb. is recommended at this time as a reasonably conservative value for the over-all injury threshold level. Volunteers tolerated impact loads to the knee of 800-1000 lb. For loads applied over the sternum through a 25-30 padded surface, static and dynamic thoracic stiffness characteristics were determined for a limited number of cadavers.
Technical Paper

A Procedure for Normalizing Impact Response Data

1984-04-01
840884
For prescribed test conditions, a procedure is given for estimating the response characteristics of an arbitrary chosen standard subject based on the measured responses of subjects with different physical characteristics. Simple model analysis is used to develop the relationships between the subjects' responses and their physical characteristics. This analysis assures dimensional correctness among the critical parameters. The technique is applied to force-time data obtained by the Association Peugeot-Renault for lateral thoracic impacts of cadaver specimens. An averaged, normalized response curve is given for each of two impact conditions. A response corridor is prescribed for each average curve. These corridors can be used to assess the efficacy of various proposed thoracic side impact test devices exposed to similar impact conditions.
Technical Paper

Small Car Air Cushion Performance Considerations

1985-04-01
851199
A critical performance issue in the development of any air cushion restraint system is the dichotomy that exists between the inflation rate required to meet the 30 mph frontal, rigid barrier restraint performance requirements and the effect that this parameter has on increasing the risk of deployment-induced injuries to out-of-position occupants. In general, small cars experience greater vehicle deceleration levels than large vehicles in FMVSS 208, 30 mph frontal, rigid barrier tests due to tighter packaging of their front-end components. In order to meet the FMVSS 208 performance requirements for such cars, the small car air cushion must be thicker and inflated faster than the large car air cushion. Such air cushion technology will increase the risk of life-threatening, deployment-induced injuries to out-of-position occupants of the small car.
Technical Paper

Biofidelity of the Hybrid III Head

1985-06-01
851245
An analysis was done of published forehead head impact data from cadaver specimens. Only data that were sufficiently documented to allow duplication of the impact environment were used in the analysis. A Hybrid III head, a Part 572 head, a Repeatable Pete head and two WSU heads were subjected to the same impact environments as the cadavers. A comparison of peak resultant head accelerations indicated that the Hybrid III response was the most representative of the cadaver data. The Part 572 head produced accelerations which were greater than the responses of the cadavers. These results support the claim that the Hybrid III head's response is humanlike for forehead impacts.
Technical Paper

The Position of the United States Delegation to the ISO Working Group 6 on the Use of HIC in the Automotive Environment

1985-06-01
851246
A review and analysis of existing cadaver head impact data has been conducted in this paper. The association of the Head Injury Criterion with experimental cadaver skull fracture and brain damage has been investigated, and risk curves of HIC versus skull fracture and brain damage have been developed. Limitation of the search for the maximum HIC duration to 15ms has been recommended for the proper use of HIC in the automotive crash environment.
Technical Paper

Restraint Performance of the 1973-76 GM Air Cushion Restraint System

1988-02-01
880400
Case reviews are given of deployment accidents of the GM 1973-76 air cushion restraint system where the occupant injury was AIS 3 or greater. Many of these injuries occurred in frontal accidents of minor to moderate collision severity where there was no intrusion or distortion of the occupant compartment. Dummy and animal test results are noted that indicate that these types of injuries could have occurred if the occupant was near the air cushion module at the time of cushion deployment. An analysis is given that indicates that for frontal accidents a restraint effectiveness of 50 percent in mitigating AIS 3 or greater injuries might be achieved if an air cushion system can be designed which would not seriously injure out-of-position occupants while still providing restraint for normally seated occupants.
Technical Paper

Comparison of the EUROSID and SID Impact Responses to the Response Corridors of the International Standards Organization

1989-02-01
890604
Side impact tests were conducted on the EUROSID and SID to assess their biofidelity compared to the response requirements of the international Standards Organization. The body regions evaluated were the head, neck, thorax, shoulder, abdomen, and pelvis. Test conditions and data normalization procedures are outlined in the report. Data plots are given which compare the impact response of each dummy to the ISO requirements. The EUROSID gave humanlike responses for most tests involving padded surface impacts, but its responses were not humanlike for rigid surface impacts. Overall, the EUROSID responses were more humanlike than the responses of the SID.
Technical Paper

Injury Risk Curves for Children and Adults in Frontal and Rear Collisions

1997-11-12
973318
This paper describes the development of injury risk curves for measurements made with the CRABI and Hybrid III family of biofidelic child and adult dummies that are used to evaluate restraint systems in frontal and rear-end collision simulations. Injury tolerance data are normalized for size and strength considerations. These data are analyzed to give normalized injury risk curves for neck tension, neck extension moment, combined neck tension and extension moment, sternal compression, the rate of sternal compression, and the rate of abdominal compression for children and adults. Using these injury risk curves dummy response limits can be defined for prescribed injury risk levels. The injury risk levels associated with the various injury assessment reference values currently used with the CRABI and Hybrid III family of dummies are noted.
Technical Paper

Evaluation of the Field Relevance of Several Injury Risk Functions

2010-11-03
2010-22-0004
An evaluation of the four injury risk curves proposed in the NHTSA NCAP for estimating the risk of AIS≻=3 injuries to the head, neck, chest and AIS≻=2 injury to the Knee-Thigh-Hip (KTH) complex has been conducted. The predicted injury risk to the four body regions based on driver dummy responses in over 300 frontal NCAP tests were compared against those to drivers involved in real-world crashes of similar severity as represented in the NASS. The results of the study show that the predicted injury risks to the head and chest were slightly below those in NASS, and the predicted risk for the knee-thigh-hip complex was substantially below that observed in the NASS. The predicted risk for the neck by the Nij curve was greater than the observed risk in NASS by an order of magnitude due to the Nij risk curve predicting a non-zero risk when Nij = 0. An alternative and published Nte risk curve produced a risk estimate consistent with the NASS estimate of neck injury.
Technical Paper

Improved Neck Injury Risk Curves for Tension and Extension Moment Measurements of Crash Dummies

2000-01-01
2000-01-SC05
This paper describes improvements made to the injury risk curves for peak neck tension, peak neck extension moment and a linear combination of tension and extension moment that produce peak stress in the anterior-longitudinal ligament at the head-to-neck junction. Data from previously published experiments that correlated neck injuries to 10-week-old, anesthetized pigs and neck response measurements of a 3-year-old child dummy that were subjected to similar airbag deployments are updated and used to generate Normal probability curves for the risk of AIS ≥ 3 neck injury for the 3-year-old child. These curves are extended to other sizes and ages by normalizing for neck size. Factors for percent of muscle tone and ligamentous failure stress as a function of age are incorporated in the risk analysis. The most sensitive predictor of AIS ≥ 3 neck injury for this data set is peak neck tension.
Technical Paper

Evaluation of the ES-2re Dummy in Biofidelity, Component, and Full Vehicle Crash Tests

2005-11-09
2005-22-0021
This technical paper presents the results from tests conducted with the ES-2re, a version of the ES-2 side impact dummy that was modified by the National Highway Traffic Safety Administration (NHTSA) to improve its performance in crash tests. Through the series of biofidelity tests conducted on the ES-2re, described in International Standards Organization (ISO) Technical Report (TR)9790 (1999), the OSRP observed a final overall biofidelity ranking of 4.1 for the ES-2re, which corresponds to an ISO classification of “marginal.” The biofidelity of the ES-2re is compared to that of the ES-2 and the WorldSID. Repeatability was also evaluated on the ES-2re based on the biofidelity test data. Additional pendulum tests were performed to assess the response of the dummy in oblique loading conditions, and results indicate that oblique loading from the front leads to significantly reduced rib deflections.
Technical Paper

Side Impact Response Corridors for the Rigid Flat-Wall and Offset-Wall Side Impact Tests of NHTSA Using the ISO Method of Corridor Development

2005-11-09
2005-22-0019
The purpose of this paper is to compare the biofidelity rating schemes of ISO/TR9790 and the NHTSA Bio Rank System. This paper describes the development of new impact response corridors being proposed for ISO/TR9790 from the results of a recent series of side-impact sled tests. The response data were analyzed by methods consistent with ISO/TR9790, including normalization by impulse-momentum analysis and the elimination of subjects that sustained six or more rib fractures. Unlike ISO/TR9790, this paper proposes the elimination of the data from tests in which the timing and the sequence of loading of the individual impact plates were inconsistent compared to other tests conducted with the same impact wall configuration.