Refine Your Search

Search Results

Viewing 1 to 15 of 15
Standard

ROAD VEHICLES – 60 V AND 600 V SINGLE CORE (ISO/METRIC) CABLES – DIMENSIONS, TEST METHODS AND REQUIREMENTS

2017-07-13
CURRENT
USCAR23-1
This International Standard specifies the dimensions, test methods, and requirements for single core 60 V cables intended for use in road vehicle applications where the nominal system voltage is ≤ (60 V DC or 25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is > (60 V DC or 25 V AC) to ≤ (600 V DC or 600 V AC). It also applies to individual cores in multi-core cables. See ISO 6722 for “Temperature Class Ratings”.
Standard

ROAD VEHICLES – 60 V AND 600 V SINGLE CORE (ISO/METRIC) CABLES – DIMENSIONS, TEST METHODS AND REQUIREMENTS

2002-09-09
HISTORICAL
USCAR23
This International Standard specifies the dimensions, test methods, and requirements for single core 60 V cables intended for use in road vehicle applications where the nominal system voltage is ≤ (60 V DC or 25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is > (60 V DC or 25 V AC) to ≤ (600 V DC or 600 V AC). It also applies to individual cores in multi-core cables. See ISO 6722 for “Temperature Class Ratings”.
Standard

PERFORMANCE SPECIFICATION FOR WELDED WIRE-TO-WIRE SPLICES

2018-06-14
CURRENT
USCAR45
SAE/USCAR-45 defines test methods and performance requirements for ultrasonically-welded wire-to-wire splices for automotive applications. Face-to-face, butt splice, and center strip configurations per Figure 1 can be tested. The tests defined in this specification subject samples on test to stresses that simulate a lifetime of exposure for a road vehicle. Stresses called out in this specification include thermal shock, temperature/humidity cycling and mechanical stress from different directions.
Standard

Performance Specification for Ultrasonically Welded Wire/Cable Termination

2009-12-18
HISTORICAL
USCAR38
IMPORTANT NOTICE: In any intended vehicle application, if the products covered by this specification are, or may be, subjected to conditions beyond those described in this document, they must pass special tests simulating the actual conditions to be encountered before they can be considered acceptable for actual vehicle application. Products certified by their supplier as having passed specific applicable portions of this specification are not to be used in applications where conditions may exceed those for which the product has been satisfactorily tested. The Authorized Person is the final authority as to what tests are to be performed on his or her parts and for what purpose these tests are required. He or she is also the final authority for resolving any questions related to testing to this specification and to authorizing any deviations to the equipment or procedures contained in this specification.
Standard

PERFORMANCE SPECIFICATION FOR ULTRASONICALLY WELDED WIRE TERMINATIONS

2016-04-05
HISTORICAL
USCAR38-1
This specification defines test methods and performance criteria for evaluating ultrasonically welded wire-to-terminal metallurgical bonds. The examples used are specific to the linear weld type of process equipment. USCAR-38 is not applicable for “Splice Welding”. The specification is applicable to wire-on-pad configurations with a typical weld shown in Figure 1. This test specification subjects parts under test to environmental exposures to simulate a lifetime of field exposure for a road vehicle. Exposures called-out in this specification include Thermal Shock, Temperature Humidity Cycling and mechanical abuse. This test specification is intended to evaluate the strength and performance of the interface between wires to an electrical terminal. Validation of the performance of the Terminal is a separate task and can be accomplished using a component validation test such as SAE/USCAR-2, which evaluates whether the entire connection system is acceptable.
Standard

COAXIAL CABLE CONNECTOR INTERFACE – SQUARE OUTER CONDUCTOR

2002-02-22
HISTORICAL
USCAR19
This radio frequency (RF) connector interface specification is suited for unsealed automobile applications up to 2 GHz. Dimensional requirements are specified in this document to ensure interchangeability. This RF connector interface specification is intended for in-line, board mount, device mount, straight or angled applications. Performance requirements are specified in SAE/USCAR-2, and in SAE/USCAR-17.
Standard

COAXIAL CABLE CONNECTOR INTERFACE – SQUARE OUTER CONDUCTOR

2003-03-10
HISTORICAL
USCAR19-1
This radio frequency (RF) connector interface specification is suited for unsealed automobile applications up to 2 GHz. Dimensional requirements are specified in this document to ensure interchangeability. This RF connector interface specification is intended for in-line, board mount, device mount, straight or angled applications. Performance requirements are specified in SAE/USCAR-2, and in SAE/USCAR-17.
Standard

PERFORMANCE SPECIFICATION FOR CABLE-TO-TERMINAL ELECTRICAL CRIMPS

2020-01-22
CURRENT
USCAR21-4
This specification defines test methods and requirements for validation of solderless crimped connections. The purpose of this test is to simulate in the lab the stress seen in a typical life (15 years and 150000 miles) for a crimp connection and assure the crimp is mechanically strong and electrically stable. This specification was developed for use with stranded automotive copper wire. Only where specifically mentioned are other constructions or other core materials (aluminum, clad, steel core, etc.) applicable. This specification does not apply to wire types not mentioned, such as coaxial cable crimps, unless a USCAR-21 test is specifically referenced in the test specification for that wire type. This specification is based on accepted levels of environmental exposure for automotive applications.
Standard

PERFORMANCE SPECIFICATION FOR CABLE-TO-TERMINAL ELECTRICAL CRIMPS

2014-11-01
HISTORICAL
USCAR21-3
This specification defines test methods and requirements for validation of solderless crimped connections. The purpose of this test is to simulate in the lab the stress seen in a typical life (15 years and 150,000 miles) for a crimp connection and assure the crimp is mechanically strong and electrically stable. This specification was developed for use with stranded automotive copper wire. Only where specifically mentioned are other constructions or other core materials (aluminum, clad, steel core, etc.) applicable. This specification does not apply to wire types not mentioned. This specification is based on accepted levels of environmental exposure for automotive applications.
Standard

PERFORMANCE SPECIFICATION FOR AUTOMOTIVE RF CONNECTOR SYTEMS

2002-02-22
HISTORICAL
USCAR17
Procedures included within this specification are intended to cover performance testing at all phases of development, production, and field analysis of electrical terminals, connectors and components for coaxial cable connection systems (hereafter referred to as RF connectors) in road vehicle applications. The intent of this specification is to qualify RF connectors that operate at frequencies greater than 200 MHz. This specification does not apply to single conductor wire or twisted pair connection systems. The RF connection system will be qualified for specific coaxial cable; the qualified coaxial cable and frequency range of interest must be listed on the connector drawing. Changing coaxial cable necessitates re-qualification. This specification is a supplement to the SAE/USCAR-2 Performance Standard for Automotive Electrical Connector Systems and all requirements herein must be met in addition to all requirements of SAE/USCAR-2, unless otherwise specified.
Standard

PERFORMANCE SPECIFICATION FOR AUTOMOTIVE RF CONNECTOR SYSTEMS

2002-11-18
HISTORICAL
USCAR17-1
Procedures included within this specification are intended to cover performance testing at all phases of development, production, and field analysis of electrical terminals, connectors and components for coaxial cable connection systems (hereafter referred to as RF connectors) in road vehicle applications. The intent of this specification is to qualify RF connectors that operate at frequencies greater than 200 MHz. This specification does not apply to single conductor wire or twisted pair connection systems. The RF connection system will be qualified for a specific coaxial cable; the qualified coaxial cable and frequency range of interest must be listed on the connector drawing. Changing coaxial cable necessitates re-qualification.
Standard

PERFORMANCE SPECIFICATION FOR AUTOMOTIVE RF CONNECTOR SYSTEMS

2023-07-10
CURRENT
USCAR17-6
This document contains procedures for testing performance of SMB-style electrical terminals, connectors and components for coaxial cable connection systems intended for road vehicle applications. These are often called FAKRA II designs. This specification does not apply to the Non RF portion of a Hybrid RF connection system. The intent of this specification is to qualify sealed and unsealed RF connectors that operate at frequencies from DC to 6 GHz. The characteristic impedance of the SMB/FAKRA connection system is 50 ohms however this specification does not exclude the use of these RF connectors on non-50 ohm cables or systems. This specification does not apply to single conductor wire or twisted pair connection systems. This specification (along with SAE/USCAR 18) is designed to provide the mechanical and electrical data required to insure that assemblies from various manufacturers will perform reliably in actual conditions.
X