Refine Your Search

Topic

Search Results

Standard

R-1234yf [HFO-1234yf] Refrigerant Electronic Leak Detectors, Minimum Performance Criteria

2016-10-20
CURRENT
J2913_201610
This SAE Standard provides testing and functional requirements to meet specified minimum performance criteria for electronic probe-type leak detectors. The equipment specified here will identify smaller refrigerant leaks when servicing motor vehicle air conditioning systems, including those engineered with improved sealing and smaller refrigerant charges to address environmental concerns and increase system efficiency. This document does not address any safety issues concerning the equipment design or use beyond that of sampling a flammable refrigerant save those described in 3.1 and 3.2 of this document. All requirements of this standard shall be verified in SAE J2911.
Standard

Criteria for Refrigerant Identification Equipment for Use with Mobile Air-Conditioning Systems

2011-05-26
CURRENT
J1771_201105
This SAE Standard applies to refrigerant identification equipment to be used for identifying refrigerant CFC-12 (R-12) and HFC-134a (R-134a) refrigerant when servicing a mobile A/C system or for identifying refrigerant in a container to be used to charge a mobile A/C system. Identification or other refrigerants are the option of the equipment manufacturer.
Standard

Procedure Retrofitting CFC-12 (R-12) Mobile Air-Conditioning Systems to HFC-134a (R-134a)

2011-04-01
CURRENT
J1661_201104
The purpose of this SAE Recommended Practice is to provide a service procedure for retrofitting a CFC-12 (R-12) system to HFC-134a (R-134a) while preserving performance and integrity of the air-conditioning (A/C) system. The steps outlined in this procedure are complete when combined with good service practices and the vehicle manufacturer's recommendations (if available) for retrofitting their models. Separate service equipment, for CFC-12 (R-12) and HFC-134a (R-134a), including refrigerant recovery/ recycle (R/R), service manifolds, vacuum pumps, and charging equipment shall be used to preserve the purity of the refrigerants and the mobile A/C systems. This procedure will minimize release of refrigerant to the atmosphere, and will preserve the integrity of the recycled CFC-12 (R-12) and HFC-134a (R-134a) supplies. This document applies to A/C systems used to cool the passenger compartment of automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems.
Standard

Recommended Service Procedure for the Containment of CFC-12 (R-12)

2011-05-26
CURRENT
J1989_201105
During service of mobile air-conditioning (A/C) systems, containment of the refrigerant is important. This procedure provides service guidelines for technicians when repairing vehicles and operating equipment defined in SAE J1990.
Standard

Performance Criteria for Electronic Refrigerant Leak Detectors

2011-04-01
CURRENT
J1627_201104
This SAE Standard applies to electronic probe-type leak detectors used to service motor vehicle passenger compartment air-conditioning systems. This document does not address any safety issues concerning their design or use.
Standard

R-1234yf [HFO-1234yf] and R-744 Technician Training for Service and Containment of Refrigerants Used in Mobile A/C Systems

2011-10-04
HISTORICAL
J2845_201110
Technician training is required to ensure that recommended procedures are used for service and repair of Mobile Air Conditioning (MAC) systems using R-744 and/or R-1234yf. Unique requirements for each refrigerant are detailed within this standard. Technicians may be trained in either or both refrigerants. The technician shall be trained to recognize which refrigerant is being handled, how to handle it safely and be equipped with the essential information, proper equipment and tools, which are unique to these refrigerants. This standard outlines minimum content requirements for such training programs. Training programs designed in accordance with this standard are not intended to ensure or assess the technical skills of technicians regarding the diagnosis and repair of motor vehicle air conditioners. Rather, the goal of such programs is to provide information to technicians about safely handling refrigerants.
Standard

R-1234yf [HFO-1234yf] and R-744 Technician Training for Service and Containment of Refrigerants Used in Mobile A/C Systems

2013-01-14
HISTORICAL
J2845_201301
Technician training is required to ensure that recommended procedures are used for service and repair of Mobile Air Conditioning (MAC) systems using R-744 and/or R-1234yf. Unique requirements for each refrigerant are detailed within this standard. Technicians may be trained in either or both refrigerants. The technician shall be trained to recognize which refrigerant is being handled, how to handle it safely and be equipped with the essential information, proper equipment and tools, which are unique to these refrigerants. This standard outlines minimum content requirements for such training programs. Training programs designed in accordance with this standard are not intended to ensure or assess the technical skills of technicians regarding the diagnosis and repair of motor vehicle air conditioners. Rather, the goal of such programs is to provide information to technicians about safely handling refrigerants.
Standard

R-12 (CFC-12), R-134a (HFC-134a), R-1234yf (HFO-1234yf), R-744, and R-152a (HFC-152a) Technician Training for Service and Containment of Refrigerants Used in Mobile A/C Systems

2021-11-09
CURRENT
J2845_202111
Mobile air conditioning (MAC) systems used in passenger cars and light duty trucks are covered by these SAE Standards when servicing the refrigerant system. Technician training is required to ensure that recommended procedures are used for service and repair of MAC systems using R-12, R-134a, R-1234yf, R-744, and R-152a refrigerants. Unique requirements for each refrigerant are detailed within this standard. Technicians may be trained in any or all refrigerants. The technician shall be trained to recognize which refrigerant is being handled and how to handle it safely, and be equipped with the essential information, proper equipment, and tools which are unique to these refrigerants. This standard outlines minimum content requirements for such training programs. Training programs designed in accordance with this standard are not intended to ensure or assess the technical skills of technicians regarding the diagnosis and repair of motor vehicle air conditioners.
Standard

R-1234yf [HFO-1234yf] and R-744 Technician Training for Service and Containment of Refrigerants Used in Mobile A/C Systems

2011-02-04
HISTORICAL
J2845_201102
Technician training is required to ensure that recommended procedures are used for service and repair of Mobile Air Conditioning (MAC) systems using R-744 and/or R-1234yf. Unique requirements for each refrigerant are detailed within this standard. Technicians may be trained in either or both refrigerants. The technician shall be trained to recognize which refrigerant is being handled, how to handle it safely and be equipped with the essential information, proper equipment and tools, which are unique to these refrigerants. This standard outlines minimum content requirements for such training programs. Training programs designed in accordance with this standard are not intended to ensure or assess the technical skills of technicians regarding the diagnosis and repair of motor vehicle air conditioners. Rather, the goal of such programs is to provide information to technicians about safely handling refrigerants.
Standard

HFC-134a Refrigerant Electronic Leak Detectors, Minimum Performance Criteria

2019-03-20
CURRENT
J2791_201903
This SAE Standard provides testing and functional requirements to meet specified minimum performance criteria for electronic probe-type leak detectors. So they will identify smaller refrigerant leaks when servicing all motor vehicle air conditioning systems, including those engineered with improved sealing and smaller refrigerant charges to address environmental concerns and increase system efficiency. This document does not address any safety issues concerning their design or use.
Standard

HFC-134a RECYCLING EQUIPMENT FOR MOBILE AIR-CONDITIONING SYSTEMS

1991-12-01
HISTORICAL
J2210_199112
The purpose of this SAE Recommended Practice is to establish the specific minimum equipment requirements for recycling HFC-134a that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems.
X