Refine Your Search

Search Results

Viewing 1 to 3 of 3
Technical Paper

Evaluation of In-Line Adsorber Technology

1997-02-24
970267
To meet tightening emissions standards, alternate pollution abatement technologies are necessary, such as an In-Line Adsorber (ILA) system. The ILA has a first catalyst, an adsorber, and a second catalyst. A diverter directs exhaust gas through the adsorber to capture unconverted hydrocarbons until the first catalyst reaches light-off temperature. The ILA system was designed so that the second catalyst becomes active concurrent with the adsorber hydrocarbon desorption. The system was evaluated using the FTP test with two different secondary air strategies on 3.8 liter V6 and 4.0 liter V8 vehicles. The ILA system performance consistently reduced ∼50-60% of cold start hydrocarbon emissions. This study examined a simplified ILA system designed to operate with a commercial secondary air pump powered by the engine.
Technical Paper

Modeling of SCR DeNOx Catalyst - Looking at the Impact of Substrate Attributes

2003-03-03
2003-01-0845
The present work intends to examine the selective NOx reduction efficiency of a current commercial Titanium-Vanadium washcoated catalyst and to develop a transient numerical model capable of describing the SCR process while using a wide range of inlet conditions such as space velocity, oxygen concentrations, water concentration and NO2/NO ratio. The concentrations of different components (NO, NO2, N2O, NH3, H2O and HNO3) were analyzed continuously by a FT-IR spectrometer. A temperature range from 150°C up to 650°C was examined and tests were carried out using a model exhaust gas comparable to the real diesel exhaust gas composition. There is a very good correlation between experimental and calculated results with the given chemical kinetics.
Technical Paper

Three-Way-Catalyst Modeling - A Comparison of 1D and 2D Simulations

2007-04-16
2007-01-1071
In this paper we present a comparison of two different approaches to model three-way catalyst. First, a numerical sample case simulating light-off is used to compare the 1D and the 2D models. The advantages of each code are discussed with respect to required input data, detail level of the output, comparability, and computation time. Thus, the 2D model reveals significant radial temperature gradients inside the monolith during light-off. In a second step, the 2D model is compared with experimental data. One set of data consists of an air/fuel ratio varying sweep at isothermal conditions. Another set was gained by emission measurements during a real driving MVEG tests with varying substrate cell density & inlet conditions. From these experiments the applicability of the model to numerical parameter studies is discussed.
X