Refine Your Search

Topic

Search Results

Standard

Continuous Flow Oxygen Regulator

2018-10-18
HISTORICAL
AS1197A
This standard covers regulators of the following types: Type I - Automatic Continuous Flow Type II - Adjustable Continuous Flow Type III - Pre-set Continuous Flow Class A - Cylinder Mounted Class B - Line Mounted Special - Composite Continuous Flow (Appendix)
Standard

DYNAMIC TESTING SYSTEM FOR OXYGEN BREATHING EQUIPMENT

1969-04-01
HISTORICAL
ARP1109
This ARP covers a system and method to be used, at all appropriate altitudes, in testing of breathing oxygen systems consisting of demand regulator, connecting hose, and mask, or regulator and helmet systems, or individual components.
Standard

HIGH PRESSURE OXYGEN SYSTEM FILLER VALVE

1971-07-30
HISTORICAL
AS1225
This AS covers oxygen filler valves for use in aircraft to ensure safe servicing of high pressure oxygen system cylinders. The intent is that the valve shall automatically control the rate of fill such that the temperature rise in the oxygen system caused by compression heating of the gas will be within acceptable limits. In addition, the valve shall have a pressure sensitive closing valve to automatically control the final pressure for a correct amount of oxygen in the system cylinder. The pressure closing level may be manually selected by means of adjustment dials on the valve.
Standard

MINIMUM STANDARD FOR OXYGEN PRESSURE REDUCERS

1991-09-01
HISTORICAL
AS1248
This standard is designed to cover all types of pressure reducers required for oxygen systems and for all performance profiles without regard for a particular inlet pressure or outlet pressure performance curve. Special attention will be given, however, to construction requirements essential in reducers where critical high initial oxygen pressures such as 1850 to 2250 psig (12.76 to 15.51 MN/m2 gauge) at 70° F (21.1° C) are involved.
Standard

MINIMUM STANDARD FOR PORTABLE GASEOUS, OXYGEN EQUIPMENT

1976-02-01
HISTORICAL
AS1046A
This standard is intended to apply to that portable compressed gaseous oxygen equipment used for the administration of supplementary and/or first aid oxygen to one or more occupants of either private or commercial transport aircraft.
Standard

MINIMUM STANDARDS FOR VALVE, HIGH PRESSURE OXYGEN, CYLINDER SHUT OFF, MANUALLY OPERATED

1996-07-01
HISTORICAL
AS1066A
This standard covers all types of manually operated high pressure oxygen, cylinder shut off valves for use in commercial type aircraft. It is intended that the valve shall be attached to a pressure cylinder storing oxygen under pressure of 1800 to 2100 psig at 70 °F. Upon opening the valve, oxygen will be permitted to discharge from the storage cylinder to the valve outlet and thence to other components of the oxygen system. It shall also be possible to recharge the cylinder through the valve.
Standard

MINIMUM STANDARDS FOR VALVE, HIGH PRESSURE OXYGEN, CYLINDER SHUT OFF, MANUALLY OPERATED

1968-12-01
HISTORICAL
AS1066
This standard covers all types of manually operated high pressure oxygen, cylinder shut off valves for use in commercial type aircraft. It is intended that the valve shall be attached to a pressure cylinder storing oxygen under pressure of 1800 to 2100 psig at 70 F. Upon opening the valve, oxygen will be permitted to discharge from the storage cylinder to the valve outlet and thence to other components of the oxygen system. It shall also be possible to recharge the cylinder through the valve.
Standard

Minimum Standard for Portable Gaseous, Oxygen Equipment

2000-03-01
HISTORICAL
AS1046B
This standard is intended to apply to that portable compressed gaseous oxygen equipment used for the administration of supplementary and/or first aid oxygen to one or more occupants of either private or commercial transport aircraft. This standard is applicable to the following types of portable oxygen equipment: a Continuous flow; b Demand flow; 1 Straight demand 2 Diluter demand 3 Pressure demand c Combination continuous flow and demand flow.
Standard

Minimum Standards for Valve, High Pressure Oxygen, Cylinder Shut Off, Manually Operated

2023-04-26
CURRENT
AS1066B
This standard covers all types of manually operated high pressure oxygen, cylinder shut off valves for use in commercial aircraft. It is intended that the valve shall be attached to a pressure cylinder storing oxygen under a nominal pressure of 12.76 MPa (1850 psig) at 21 °C (70 °F). Upon opening the valve, oxygen will be permitted to discharge from the storage cylinder to the valve outlet and to other downstream components of the oxygen system. It shall also be possible to recharge the cylinder through the valve.
Standard

Oxygen Cylinder Installation Guide

2019-04-11
CURRENT
ARP5021B
This document provides guidance for oxygen cylinder installation on commerical aircraft based on airworthiness requirements, and methods practiced within aerospace industry. It covers considerations for oxygen systems from beginning of project phase up to production, maintenance, and servicing. The document is related to requirements of DOT-approved oxygen cylinders, as well to those designed and manufactured to standards of ISO 11119. However, its basic rules may also be applicable to new development pertaining to use of such equipment in an oxygen environment. For information regarding oxygen cylinders itself, also refer to AIR825/12.
Standard

Oxygen Cylinder Installation Guide

2016-11-18
HISTORICAL
ARP5021A
This document provides guidance for oxygen cylinder installation on commercial aircraft based on rules and methods practiced in aerospace industry and applicable in other associations. It covers considerations for oxygen systems from beginning of project phase up to production, maintenance, and servicing. The document is focused on requirements regarding DOT approved oxygen cylinders. However, its basic rules may also be applicable to new development pertaining to use of such equipment in an oxygen environment. For information regarding oxygen cylinders itself, reference should be made to AIR825/12 also.
Standard

Oxygen Cylinder Installation Guide

2005-10-24
HISTORICAL
ARP5021
This document provides guidance for oxygen cylinder installation on commercial aircraft based on rules and methods practiced in aerospace industry and as far as applicable in other associations. It covers considerations to be taken for oxygen systems from beginning of project phase up to production, maintenance, and servicing. The document is focused on requirements regarding DOT approved oxygen cylinders. However, its basic rules may also be applicable to new development pertaining to use of such equipment in an oxygen environment. For information regarding oxygen cylinders itself, reference should be made to AIR825/12 also.
Standard

Oxygen Cylinder Quality, Serviceability, Maintenance Transfilling and Marking

2017-05-19
HISTORICAL
AIR1059E
This document provides guidance concerning the maintenance and serviceability of oxygen cylinders beginning with the quality of oxygen that is required, supplemental oxygen information, handling and cleaning procedures, transfilling and marking of serviced oxygen assemblies. This document attempts to outline in a logical sequence oxygen quality, serviceability, and maintenance of oxygen cylinders. Content of this document can also be used for refilling of oxygen cylinder while installed on aircraft, directly or through an intermediate charging port.
Standard

Oxygen Cylinder Quality, Serviceability, Maintenance Transfilling and Marking

2010-10-14
HISTORICAL
AIR1059C
This document provides guidance concerning the maintenance and serviceability of oxygen cylinders beginning with the quality of oxygen that is required, supplemental oxygen information, handling and cleaning procedures, transfilling and marking of serviced oxygen assemblies. This document attempts to outline in a logical sequence oxygen quality, serviceability and maintenance of oxygen cylinders.
Standard

Oxygen Cylinder Quality, Serviceability, Maintenance Transfilling and Marking

2014-11-13
HISTORICAL
AIR1059D
This document provides guidance concerning the maintenance and serviceability of oxygen cylinders beginning with the quality of oxygen that is required, supplemental oxygen information, handling and cleaning procedures, transfilling and marking of serviced oxygen assemblies. This document attempts to outline in a logical sequence oxygen quality, serviceability and maintenance of oxygen cylinders.
X