Refine Your Search

Topic

Author

Affiliation

Search Results

Event

2024-04-23
Technical Paper

10 KWe Dual-Mode Space Nuclear Power System for Military and Scientific Applications

1992-08-03
929072
A 10 KWe dual-mode space power system concept has been identified which is based on INEL's Small Externally-fueled Heat Pipe Thermionic Reactor (SEHPTR) concept. This power system will enhance user capabilities by providing reliable electric power and by providing two propulsion systems; electric power for an arc-jet electric propulsion system and direct thrust by heating hydrogen propellant inside the reactor. The low thrust electric thrusters allow efficient station keeping and long-term maneuvering. The direct thrust capability can provide tens of pounds of thrust at a specific impulse of around 730 seconds for maneuvers that must be performed more rapidly. The direct thrust allows the nuclear power system to move a payload from Low Earth Orbit (LEO) to Geosynchronous Earth Orbit (GEO) in less than one month using approximately half the propellant of a cryogenic chemical stage.
Standard

10 Megabit/sec Network Configuration Digital Time Division Command/Response Multiplex Data Bus

2013-04-29
HISTORICAL
AS5652
This SAE Aerospace Standard (AS) contains requirements for a digital time division command/response multiplex data bus, for use in systems integration that is functionally similar to MIL-STD-1553B with Notice 2 but with a star topology and some deleted functionality. Even with the use of this document, differences may exist between multiplex data buses in different system applications due to particular application requirements and the options allowed in this document. The system designer must recognize this fact and design the multiplex bus controller (BC) hardware and software to accommodate such differences. These designer selected options must exist to allow the necessary flexibility in the design of specific multiplex systems in order to provide for the control mechanism, architectural redundancy, degradation concept, and traffic patterns peculiar to the specific application requirements.
Standard

10 Megabit/sec Network Configuration Digital Time Division Command/Response Multiplex Data Bus

2018-01-18
CURRENT
AS5652A
This SAE Aerospace Standard (AS) contains requirements for a digital time division command/response multiplex data bus, for use in systems integration that is functionally similar to MIL-STD-1553B with Notice 2 but with a star topology and some deleted functionality. Even with the use of this document, differences may exist between multiplex data buses in different system applications due to particular application requirements and the options allowed in this document. The system designer must recognize this fact and design the multiplex bus controller (BC) hardware and software to accommodate such differences. These designer selected options must exist to allow the necessary flexibility in the design of specific multiplex systems in order to provide for the control mechanism, architectural redundancy, degradation concept, and traffic patterns peculiar to the specific application requirements.
Standard

1000BASE-T1 Un-Shielded and Shielded Balanced Single Twisted Pair Ethernet Cable

2021-11-03
HISTORICAL
J3117/2_202111
This standard covers un-shielded (JUTP) and shielded (STP) balanced single twisted pair jacketed data cable intended for use in surface vehicle cables for 1 Gb/s ethernet applications. The tests in this standard are intended to qualify cables for normal operation in an automotive environment while maintaining the necessary electrical properties for reliable data transmission.
Standard

1000BASE-T1 Un-Shielded and Shielded Balanced Single Twisted Pair Ethernet Cable

2022-09-30
CURRENT
J3117/2_202209
This standard covers un-shielded (JUTP) and shielded (STP) balanced single twisted pair jacketed data cable intended for use in surface vehicle cables for 1000BASE-T1 ethernet PHY (1 Gb/s) applications. The tests in this standard are intended to qualify cables for normal operation in an automotive environment while maintaining the necessary electrical properties for reliable data transmission.
Standard

100BASE-T1 Un-Shielded Balanced Single Twisted Pair Ethernet Cable

2023-01-17
CURRENT
J3117/1_202301
This SAE Standard covers un-shielded balanced single twisted pair data cable intended for use in surface vehicle cables for ≤100 Mb/s Ethernet applications. The tests in this document are intended to qualify cables for normal operation in an automotive environment while maintaining the necessary electrical properties for reliable data transmission.
Technical Paper

14/42V - Electrical Power Supply Systems Consequences for Electrical Interconnections and Switches

2000-08-21
2000-01-3055
This paper provides an overview about the consequences of a 14/42 V - Electrical Power Supply System for the Electrical Interconnection and Switching Technology. It presents design guidelines and solutions for connector systems including advanced applications like fuse and relay boxes and gives an overview of those existing connectors already suited for 42 V and even higher voltages. The problem of arcing due to the increased voltage is discussed for the case that mating and unmating under load has to be taken into consideration. Arcing also has a tremendous impact on the design of 42 V proof relays. Therefore, some basic results be presented along with proposals how these problems can be overcome by appropriate designs. Another part of the paper looks at the electrical power supply system itself. Here interconnection techniques for new battery systems are discussed. Finally, the chances for new technologies are highlighted.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2020-02-25
CURRENT
J2691_202002
This SAE Standard establishes the minimum construction and performance requirements for a 15 pole connector between towing vehicles and trailers, for trucks, trailers, and dollies, for 12 VDC nominal applications in conjunction with SAE J2742. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2018-04-15
HISTORICAL
J2691_201804
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2013-04-09
HISTORICAL
J2691_201304
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742 “Combination 11 Conductors and 4 Pairs ECBS Cable”. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Technical Paper

1553 RT Mechanizations for Data Sample Consistency and Multi-Message Transfers

1993-04-01
931600
System requirements and Interface Control Drawings (ICDs) make a variety of demands for MIL-STD-1553 remote terminals (RTs). Among these requirements are the need to ensure data integrity and sample data consistency, the need to perform bulk (multi-message) data transfers, and the need to offload the operation of the host CPU to the greatest degree possible. This latter requirement is reflected in such specifications as CPU spare bandwidth. The latest 1553 terminals provide a variety of choices for performing the different types of transfers. This paper provides a discussion of the hardware and software techniques for achieving these objectives. Three different schemes for RT subaddress memory management are presented: single message, circular buffer, and double buffered. For receive and transmit messages, these include fully synchronous single message transfers, asynchronous single message transfers, and multi-message transfers.
Technical Paper

16-Channel Portable Data Acquisition and Reduction System

1984-04-01
840764
A Microprocessor Data Acquisition System has been designed to be cab-mounted in vehicles or used in laboratories to acquire up to 16 channels of test data. This data may be acquired as time-at-level histograms in one or two dimensions with min-max-mean data recovery, time histories, or peaks and valleys stored on digital tape. The system includes a microcomputer-based Playback/Support Box that simplifies playback of data tapes for computer analysis or stand-alone data plotting using a graphics terminal.
Standard

280 RELAY FOOTPRINT

1994-06-01
CURRENT
J1744_199406
This SAE Standard covers a terminal footprint for mini and micro relays used in surface vehicle electrical systems.
Technical Paper

3-D Numerical Analysis Investigating Distribution of Contact Pressures for a Number of Cylindrical Bearing Axial Profiles When Placed Under Radial Load Conditions

2009-04-20
2009-01-1193
Increased torque values passing from engine to transmission have, increasingly become a problem regarding shaft misalignment. Engineers are restricted with regard to applying ISO standards when investigating bearing life cycles as they tend only to cover normal [radial thrust] load conditions. Depending on the application, the need has arisen for numerical models to determine reduction in normal life cycles due to abnormal running conditions. The Simulia Finite Element package Abaqus v6.7 provides trends in the deformations, contact pressures and their respective distribution. It was found the most efficient profile, with regards to a uniform contact pressure, under both radial and misaligned conditions is the toroidal profile.
Standard

3GCN - CABIN DISTRIBUTION SYSTEM

2010-11-26
CURRENT
ARINC808-2
This Specification defines general architectural philosophy and aircraft infrastructure for the proper use and interface of various cabin related IFE equipment. Compliance with ARINC Specification 808 allows each respective system to operate in concert when integrated with other relevant cabin equipment. ARINC Specification 808 defines standards for the aircraft 3rd Generation Cabin Network (3GCN), IFE Cabin Distribution System (CDS), wiring, connectors, power, identification codes, space envelopes, and mounting principles. Although some of these standards also apply to 3GCN wireless IFE systems, the overall 3GCN wireless IFE network specification is covered in ARINC Specification 820. The equipment itself is not a subject of this specification because it may be unique to the system manufacturer or marketplace-driven. Design guidelines are included for informational purposes as these guidelines impact the interfaces and installation of cabin equipment aboard the aircraft.
X