Refine Your Search

Topic

Search Results

Standard

Automotive Refrigerant Recovery/Recycling Equipment Intended for Use With Both R12 and R134a

2010-11-05
CURRENT
J1770_201011
The purpose of this SAE Standard is to establish the specific minimum equipment requirements for recovery/recycling equipment intended for use with both R12 and R134a in a common refrigerant circuit that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. This document does not apply to equipment used for R12 and R134a having a common enclosure with separate circuits for each refrigerant.
Standard

Automotive Refrigerant Recovery/Recycling/Recharging Equipment Intended for use with Both R-1234yf and R-134a

2020-11-13
CURRENT
J3030_202011
The purpose of this SAE Standard is to establish the specific minimum equipment requirements for recovery/recycling/recharge equipment intended for use with both R-1234yf and R-134a in a common refrigerant circuit that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. This document does not apply to equipment used for R-1234yf and R-134a having a common enclosure with separate circuits for each refrigerant, although some amount of separate circuitry for each refrigerant could be used.
Standard

Automotive Refrigerant Recovery/Recycling/Recharging Equipment Intended for use with Both R-1234yf and R-134a

2015-07-08
HISTORICAL
J3030_201507
The purpose of this SAE Standard is to establish the specific minimum equipment requirements for recovery/recycling/recharge equipment intended for use with both R-1234yf and R-134a in a common refrigerant circuit that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. This document does not apply to equipment used for R-1234yf and R-134a having a common enclosure with separate circuits for each refrigerant, although some amount of separate circuitry for each refrigerant could be used.
Standard

Criteria for Refrigerant Identification Equipment for Use with Mobile Air-Conditioning Systems

2011-05-26
CURRENT
J1771_201105
This SAE Standard applies to refrigerant identification equipment to be used for identifying refrigerant CFC-12 (R-12) and HFC-134a (R-134a) refrigerant when servicing a mobile A/C system or for identifying refrigerant in a container to be used to charge a mobile A/C system. Identification or other refrigerants are the option of the equipment manufacturer.
Standard

HFC-134a (R-134a) Recovery/Recycle/Recharging Equipment for Mobile Air-Conditioning Systems

2020-01-03
CURRENT
J2788_202001
The purpose of this SAE Standard is to establish the specific minimum equipment performance requirements for recovery and recycling of HFC-134a that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. It also is intended to establish requirements for equipment used to recharge HFC-134a to an accuracy level that meets Section 9 of this document and SAE J2099. The requirements apply to the following types of service equipment and their specific applications. a Recovery/recycling equipment b Recovery/recycling-refrigerant charging c Refrigerant recharging equipment only
Standard

HFC-134a (R-134a) Recovery/Recycle/Recharging Equipment for Mobile Air-Conditioning Systems

2010-06-21
HISTORICAL
J2788_201006
The purpose of this SAE Standard is to establish the specific minimum equipment performance requirements for recovery and recycling of HFC-134a that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. It also is intended to establish requirements for equipment used to recharge HFC-134a to an accuracy level that meets Section 9 of this document and SAE J2099. The requirements apply to the following types of service equipment and their specific applications. a Recovery/Recycling Equipment, b Recovery/Recycling-Refrigerant Charging, c Refrigerant Recharging Equipment Only.
Standard

HFC-134a RECYCLING EQUIPMENT FOR MOBILE AIR-CONDITIONING SYSTEMS

1991-12-01
HISTORICAL
J2210_199112
The purpose of this SAE Recommended Practice is to establish the specific minimum equipment requirements for recycling HFC-134a that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems.
Standard

HFC-134a Refrigerant Electronic Leak Detectors, Minimum Performance Criteria

2019-03-20
CURRENT
J2791_201903
This SAE Standard provides testing and functional requirements to meet specified minimum performance criteria for electronic probe-type leak detectors. So they will identify smaller refrigerant leaks when servicing all motor vehicle air conditioning systems, including those engineered with improved sealing and smaller refrigerant charges to address environmental concerns and increase system efficiency. This document does not address any safety issues concerning their design or use.
Standard

Method for Removal of Refrigerant from Mobile Air Conditioning System to Quantify Charge Amount

2017-03-10
CURRENT
J2762_201703
This Standard provides an overview of results and requirements needed to remove refrigerant from a mobile air conditioning system for determining refrigerant emissions (leakage). This reclaim procedure for use on fleet vehicles in a field service environment should produce an accuracy and repeatability sufficient to determine refrigerant loss within 2 g.
Standard

Method for Removal of Refrigerant from Mobile Air Conditioning System to Quantify Charge Amount

2011-02-04
HISTORICAL
J2762_201102
This Standard provides an overview of results and requirements needed to remove refrigerant from a mobile air conditioning system for determining refrigerant emissions (leakage). This reclaim procedure for use on fleet vehicles in a field service environment should produce an accuracy and repeatability sufficient to determine refrigerant loss within 2 g.
Standard

Minimum Performance Requirements for Non-Refrigerant Tracer Gases and Electronic Tracer Gas Leak Detectors

2023-05-01
CURRENT
J2970_202305
This SAE Standard provides the testing and functional requirements guidance necessary for a leak detection device that uses any non-A/C refrigerant tracer gas, such as helium or a nitrogen-hydrogen blend, to provide functional performance equivalent to a refrigerant electronic leak detector. It explains how a non-refrigerant leak detector’s calibration can be established to provide levels of detection equal to electronic leak detectors that meet SAE J2791 for R-134a and SAE J2913 for R-1234yf.
Standard

Minimum Performance Requirements for Non-Refrigerant Tracer Gasses and Electronic Tracer Gas Leak Detectors

2012-07-19
HISTORICAL
J2970_201207
This standard provides the testing and functional requirements guidance necessary for a leak detection device that uses any non-A/C refrigerant tracer gas, such as helium or a nitrogen-hydrogen blend, to provide functional performance equivalent to a refrigerant electronic leak detector. It explains how a non- refrigerant leak detector’s calibration can be established to provide levels of detection equal to electronic leak detectors that meet SAE J2791 for R-134a and SAE J2913 for R-1234yf.
Standard

Minimum Performance Requirements for Non-Refrigerant Tracer Gasses and Electronic Tracer Gas Leak Detectors

2015-03-17
HISTORICAL
J2970_201503
This standard provides the testing and functional requirements guidance necessary for a leak detection device that uses any non-A/C refrigerant tracer gas, such as helium or a nitrogen-hydrogen blend, to provide functional performance equivalent to a refrigerant electronic leak detector. It explains how a non- refrigerant leak detector’s calibration can be established to provide levels of detection equal to electronic leak detectors that meet SAE J2791 for R-134a and SAE J2913 for R-1234yf.
Standard

Performance Criteria for Electronic Refrigerant Leak Detectors

2011-04-01
CURRENT
J1627_201104
This SAE Standard applies to electronic probe-type leak detectors used to service motor vehicle passenger compartment air-conditioning systems. This document does not address any safety issues concerning their design or use.
Standard

Procedure Retrofitting CFC-12 (R-12) Mobile Air-Conditioning Systems to HFC-134a (R-134a)

2011-04-01
CURRENT
J1661_201104
The purpose of this SAE Recommended Practice is to provide a service procedure for retrofitting a CFC-12 (R-12) system to HFC-134a (R-134a) while preserving performance and integrity of the air-conditioning (A/C) system. The steps outlined in this procedure are complete when combined with good service practices and the vehicle manufacturer's recommendations (if available) for retrofitting their models. Separate service equipment, for CFC-12 (R-12) and HFC-134a (R-134a), including refrigerant recovery/ recycle (R/R), service manifolds, vacuum pumps, and charging equipment shall be used to preserve the purity of the refrigerants and the mobile A/C systems. This procedure will minimize release of refrigerant to the atmosphere, and will preserve the integrity of the recycled CFC-12 (R-12) and HFC-134a (R-134a) supplies. This document applies to A/C systems used to cool the passenger compartment of automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems.