Abstract:
An 8000 psi test program was conducted to resolve conflicts and issues surrounding the use of CTFE and MIL-H-83282 fluid with vented and unvented actuator rod seals. Each of the four possible combinations had unique problems and each responded to appropriate corrections including new backup rings designed to operate with standard clearances. It was concluded that all combinations were viable within certain limits. Advantages and disadvantages of each configuration were identified and specific recommendations made for both dynamic and static seals within the context of existing military specifications.