Hydrogen Concentration Distribution in Simulated Spaces for a Hydrogen System Installed in a Large Bus in Case of Hydrogen Leakage 2008-01-0727

For fuel cell vehicles, which have attracted attention in recent years, the prevention of hydrogen leakage is an essential safety issue.
Large fuel cell buses will require a large space to store the hydrogen system. The behavior of hydrogen that has leaked into such a large space is unknown.
In this report, we studied hydrogen concentration distribution by leaking hydrogen into simulated spaces in two cases: (1) when hydrogen gas tanks are installed on the roof of the bus, and (2) when an electricity-generating system, such as fuel cell stacks, etc., is installed at the rear of the bus.
The results of the experiments show that hydrogen concentration distribution is kept at a constant level throughout each location in the simulated space, depending on the opening area and hydrogen leakage rate. It was also found that the diffusivity of hydrogen in air is extremely high. Hydrogen diffuses through openings, preventing a high concentration from accumulating inside the space, thus keeping the concentration below the lower flammable limit (LFL) of 4% (by volume), in many cases.

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
We also recommend:
TECHNICAL PAPER

Failure Analysis of Polymer Electrolyte Fuel Cells

2008-01-0634

View Details

JOURNAL ARTICLE

Investigation of the Allowable Flow Rate of Hydrogen Leakage on Receptacle

2008-01-0724

View Details

JOURNAL ARTICLE

Flame Quenching Limits of Hydrogen Leaks

2008-01-0726

View Details

X