Browse Publications Technical Papers 2014-01-0280
2014-04-01

Model-Based Fault Diagnosis of Selective Catalytic Reduction Systems for Diesel Engines 2014-01-0280

In this paper, a model-based diagnostic system was developed to detect and isolate the dosing fault and the outlet NOx sensor fault for the SCR system. The dosing fault is treated as an actuator additive fault, while the outlet NOx sensor drift and/or offset fault is treated as a sensor additive fault. First, a 0-D SCR model was developed to facilitate the model-based approach. A parity equation residual generator was designed based on the linearized SCR model and the fault transfer function matrix. The diagnostic algorithm is then implemented in the Matlab/Simulink environment for validation. A high fidelity nonlinear 1-D SCR model is used to generate system outputs and to simulate the plant. The simulation results show that the model-based fault diagnosis system succeeds in detecting and isolating the outlet NOx sensor and dosing faults with good sensitivity and robustness

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 16% off list price.
Login to see discount.
We also recommend:
TECHNICAL PAPER

Crank-Angle Resolved Modeling of Fuel Injection and Mixing Controlled Combustion for Real-Time Application In Steady-State and Transient Operation

2014-01-1095

View Details

TECHNICAL PAPER

Desktop Simulation and Calibration of Diesel Engine ECU Software using Software-in-the-Loop Methodology

2014-01-0189

View Details

TECHNICAL PAPER

Urea SCR System Characterization through Unique Flow Bench Testing

2006-01-3471

View Details