Design and Testing of Rollover Protective Structures in Accordance with SAE J395 710509
Plastic analysis type of analytical calculations are included in this paper as a guide for designers to size Rollover Protective Structures to meet SAE J-395. Basic design considerations are given including material selection, brittle failures, local buckling, and allowable deflections.
Citation: Macarus, W., "Design and Testing of Rollover Protective Structures in Accordance with SAE J395," SAE Technical Paper 710509, 1971, https://doi.org/10.4271/710509. Download Citation
Author(s):
William P. Macarus
Pages: 8
Event:
22nd Annual Earthmoving Industry Conference
ISSN:
0148-7191
e-ISSN:
2688-3627
Related Topics:
Rollover protective structures
SAE MOBILUS
Subscribers can view annotate, and download all of SAE's content.