A Simple High Shear Viscometer-Aspects of Correlation with Engine Performance 780981
A simple rotary viscometer has been constructed in which multi-grade oils can be tested at temperatures up to 150°C and at shear rates of up to 4 × 105 s-1. Correlation has been made using this apparatus between multi-grade oil shear stability and engine bearing and cylinder bore wear. However, additional tests demonstrated that the chemical action of anti-wear additives also has a major influence on cylinder bore wear.
Citation: Pike, W., Banks, F., and Kulik, S., "A Simple High Shear Viscometer-Aspects of Correlation with Engine Performance," SAE Technical Paper 780981, 1978, https://doi.org/10.4271/780981. Download Citation
Author(s):
W.C. Pike, F.R. Banks, S. Kulik
Affiliated:
BP Research Centre The British Petroleum Co., Ltd. (Middlesex/England)
Pages: 12
Event:
1978 SAE International Fall Fuels and Lubricants Meeting and Exhibition
ISSN:
0148-7191
e-ISSN:
2688-3627
Also in:
SAE 1978 Transactions-V87-A
Related Topics:
Engine cylinders
Wear
Chemicals