Test Results of Reflux-Cooled Electromechanical Actuator 942176
A two-phase thermosyphon cooler coupled with phase change material (PCM) energy storage was built to demonstrate a concept for cooling a 26 kW actuator motor. FC75®, a Fluorinert® compound, was used as the working fluid to transfer heat to the phase change material, acetamide. The PCM was contained in alternating layers of a plate-fin compact heat exchanger core. At the 90 percent power condition the peak motor temperature was within 90°C of the heat sink, showing good source to sink thermal coupling by the thermosyphon and conductive links. Conversely, when the motor was cooled by natural convection and conduction alone, the peak temperature was 190°C above sink temperature. Testing shows that the PCM material provides additional useful thermal inertia during the melting process. However, test data revealed that the melt temperature of the acetamide had been depressed from 80°C to 68°C by absorbed water, highlighting the need to process the PCM in a dry atmosphere. The lower melt temperature did not affect the overall thermal test results, and the PCM heat of fusion was not affected by the water.
Citation: Schneider, M., Thomson, S., Bland, T., and Yerkes, K., "Test Results of Reflux-Cooled Electromechanical Actuator," SAE Technical Paper 942176, 1994, https://doi.org/10.4271/942176. Download Citation
Author(s):
Michael G. Schneider, Scott M. Thomson, Timothy J. Bland, Kirk L. Yerkes
Affiliated:
Sundstrand Aerospace
Pages: 11
Event:
Aerospace Technology Conference and Exposition
ISSN:
0148-7191
e-ISSN:
2688-3627
Also in:
SAE 1994 Transactions: Journal of Aerospace-V103-1
Related Topics:
Heat exchangers
Thermal testing
Water
Sensors and actuators
SAE MOBILUS
Subscribers can view annotate, and download all of SAE's content.