Refine Your Search

Topic

Search Results

Standard

Inverter Requirements for Class Eight Trucks - Truck and Bus

2011-11-30
HISTORICAL
J2697_201111
This SAE Recommended Practice is intended to describe the application of single-phase DC to AC inverters, and bidirectional inverter/chargers, which supply power to ac loads in Class heavy duty on-highway trucks (10K GVW). The document identifies appropriate operating performance requirements and adds some insight into inverter selection. This document applies to factory and after-market installed DC-to-AC inverter systems (Including inverter chargers) providing up 3000 W of 120 VAC line-voltage power as a convenience for operator and passenger use. Such inverters are intended to power user loads not essential to vehicle Operation or safety (e.g., HVAC, TV, microwave ovens, battery chargers for mobile phones or laptop computers, audio equipment, etc.). Systems incorporate the inverter itself as well as the input, output, control, and signal wiring associated with the inverter.
Standard

Recommended Environmental Practices for Electronic Equipment Design in Heavy-Duty Vehicle Applications

2011-01-04
HISTORICAL
J1455_201101
The scope of this recommended practice encompasses the range of environments which influence the performance and reliability of the electronic equipment designed for heavy duty on and off road vehicles, as well as any appropriate stationary applications which also use these vehicle derived components. A few examples of such vehicles are on and off highway trucks, trailers, buses, construction equipment and agricultural equipment including implements.
Standard

Auxiliary Power Unit Electrical Interface Requirements for Class Eight Trucks

2010-07-06
HISTORICAL
J2891_201007
This SAE Recommended Practice covers the design and application of a 120 VAC single phase engine based auxiliary power unit or GENSET. This document is intended to provide design direction for the single phase nominal 120 VAC as it interfaces within the truck architecture providing power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off.
Standard

Heavy Duty High Speed Datalink Connector

2010-02-18
HISTORICAL
J2839_201002
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Recommended Practice for Identification of Standardized Truck and Tractor Electrical Circuits

2010-01-07
HISTORICAL
J2191_201001
This SAE document defines a recommended practice for implementing circuit identification for electrical power and signal distribution systems of the Class 8 trucks and tractors. This document provides a description of a supplemental circuit identifier that shall be utilized in conjunction with the original equipment manufacturer’s primary circuit identification as used in wire harnesses but does not include electrical or electronic devices which have pigtails. The supplemental circuit identifier is cross-referenced to a specified subsystem of the power and signal distribution system identified in Section 5.
Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design - Truck and Bus

2008-01-14
HISTORICAL
J2698_200801
1.1 This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids. 1.2 This document is not intended to provide guidance for electric or hybrid electric vehicle wiring circuits. Refer to SAE J1673 for high voltage automotive wiring assembly design. 1.3 Engine block heaters are 120 VAC devices that are used on a multitude of vehicle platforms in addition to trucks with sleeper cabs. Generally, the engine block heater circuit is wired independent of hotel loads.
Standard

Truck Tractor Power Output for Trailer ABS

2007-12-17
HISTORICAL
J2247_200712
This SAE Recommended Practice identifies the minimum truck tractor electrical power output of the stop lamp and ABS (antilock brake system) circuits measured at the primary SAE J560 tractor trailer interface connector(s).
Standard

Seven Conductor Cable for ABS Power--Truck and Bus

2007-06-22
HISTORICAL
J2394_200706
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8 2/10 4/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications. While the document's title refers to ABS Power to differentiate the document from the SAE J1067 standard that it supersedes, the scope applies to both the primary green cable for powering ABS and lighting and the yellow auxiliary cable of the same construction.
Standard

Coiled Electrical Cable - Truck and Bus

2007-06-12
HISTORICAL
J2222_200706
This SAE Standard establishes the minimum performance and endurance requirements for coiled electrical cables used for hookup between trucks, trailers and dollies. The component standards SAE J2394 (replaced SAE J1067) for cable and SAE J560 for connectors must be consulted to determine the complete performance and endurance requirements of the system. Related TMC Recommended Practices may be consulted for information associated with selection, installation and inspection of these coiled electrical cables. This document is intended to set out requirements for the majority of conditions rather than for specialized applications or environments.
Standard

Seven Conductor Cable - Truck and Bus

2007-06-12
HISTORICAL
J1067_200706
This SAE standard establishes the minimum construction and performance requirements for seven-conductor 1/8-1/10-5/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Recommended Environmental Practices for Electronic Equipment Design in Heavy-Duty Vehicle Applications

2006-06-08
HISTORICAL
J1455_200606
The climatic, dynamic, and electrical environments from natural and vehicle-induced sources that influence the performance and reliability of vehicle and tractor/trailer electronic components, are included in this sAE Recommended Practice. Test methods that can be used to simulate these environmental conditions are also included. This information is applicable to diesel power trucks in Classes 6, 7, and 8. This guideline is intended to aid the designer of automotive electronic systems and components by providing material that may be used to develop environmental design goals.
Standard

Positive Temperature Coefficient Overcurrent Protection Devices (PTCs)

2006-05-18
HISTORICAL
J2685_200605
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for P.T.C. overcurrent protection devices in amperage rating 30A or less. These devices are also typically rated with a maximum operating voltage, which for vehicular systems need to be 16 V (for 12 V systems)(, 32 V (for 24 V systems), and 58 V (for 42 V systems). P.T.C. devices are considered to be self-resetting after responding to overcurrent conditions and after such condition has been removed from the affected circuit containing the P.T.C.
Standard

Heavy-Duty Circuit Breakers

2004-09-13
HISTORICAL
J1625_200409
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for circuit breakers in ratings from 50 to 200 A. The document covers externally mounted automatic reset and manually reset types of circuit breakers for low voltage DC operation (typically 50 V or less).
Standard

Circuit Breakers

2004-06-22
HISTORICAL
J553_200406
This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 50 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 V and 24 V DC electrical systems. Some circuit breakers may have dual voltage ratings (AC and DC), however, this document evaluates DC performance only.
Standard

Heavy-Duty Wiring Systems for On-Highway Trucks

2004-05-10
HISTORICAL
J2202_200405
This SAE Recommended Practice is intended to describe the application of the primary wiring distribution system of less than 50 V and includes cable sizes 0.5 to 19 mm2 on heavy-duty on-highway trucks. The document identifies appropriate operating performances requirements. This document excludes the male to female connection of the SAE J560 and ISO 3731 connectors.