Refine Your Search

Search Results

Viewing 1 to 7 of 7
Technical Paper

A Two-Phase Fluid Pump for Use in Microgravity Environments

1999-07-12
1999-01-1979
The two-phase pump assembly (TPPA) supports advanced thermal control systems (TCS) being developed for future orbital and deep space missions that continuously demand technological advancements to reduce cost, schedule, size, and weight. The TCS provides cooling to onboard personnel and systems by utilizing a coolant in which the working fluid undergoes vaporization and condensation while circulating in the coolant fluid loop. The considerable latent heat associated with these liquid-vapor phase transitions allows the working fluid to absorb and transport a given amount of heat energy with a significantly reduced coolant flow rate resulting in a smaller system size, volume, and mass. Properly designed heat exchangers which utilize boiling and condensation phase transitions can be made smaller and lighter than single-phase systems for a given heat dissipation load.
Technical Paper

The Continuing Evolution of the C-130 Environmental Control System

1999-07-12
1999-01-2163
The vast array of C-130 applications demand a variety of air conditioning solutions to meet the specific needs of each variant and its user. Existing C-130′s are often reconfigured for special use such as airborne early warning and control (AEW&C), electronic surveillance, or armed reconnaissance, or just upgraded to current flight standards where new equipment is added to the aircraft that significantly increases the heat load on the air conditioning system. These factors dictate the need for high-, middle-, and low-end solutions to deliver the increased cooling capacity required at a price each user can afford. This paper will recap the evolution of the C-130 environmental control system (ECS) to date, summarize current improvement efforts, and suggest future ECS developments.
Technical Paper

Long-Term Evaluation of a Hydrophilic, Antimicrobial Coating Developed for Condensing Heat Exchangers

1998-07-13
981619
A hydrophilic, antimicrobial coating has been developed for the condensing heat exchanger and filter assembly (CHXFA), part of the Environmental Control and Life Support System (ECLSS) of the Columbus Orbital Facility (COF), the European laboratory module of the International Space Station (ISS). Condensing heat exchangers (CHX) are used in many applications, including space life support systems, to control temperature and humidity. In space, condensate from the air does not drain from the heat exchanger because of the absence of gravity. To overcome this problem, slurping condensing heat exchangers have been developed which combine a hydrophilic coating on the air flow passages, and an additional slurping section added to the air outlet of the heat exchanger to achieve efficient air-water separation.
Technical Paper

Columbus Orbital Facility Condensing Heat Exchanger and Filter Assembly

1997-07-01
972409
Space environmental control systems must control cabin temperature and humidity. This can be achieved by transferring the heat load to a circulating coolant, condensing the humidity, and separating the condensate from the air stream. In addition, environmental control systems may be required to remove particulate matter from the air stream. An assembly comprised of a filter, a condensing heat exchanger, a thermal control valve, and a liquid carryover sensor, is used to achieve all these requirements. A condensing heat exchanger and filter assembly (CHXFA) is being developed and manufactured by SECAN/AlliedSignal under a contract from Dornier Daimler-Benz as part of a European Space Agency program. The CHXFA is part of the environmental control system of the Columbus Orbital Facility (COF), the European laboratory module of the International Space Station (ISS).
Technical Paper

A Thermal Control System Dual-Membrane Gas Trap for the International Space Station

1997-07-01
972410
The dual membrane gas trap filter is utilized in the internal thermal control system (ITCS) as part of the pump package assembly to remove non-condensed gases from the ITCS coolant. This improves pump performance and prevents pump cavitation. The gas trap also provides the capability to vent air that is Ingested into the ITCS during routine maintenance and replacement of the International Space Station (ISS) system orbital replacement units. The gas trap is composed of two types of membranes that are formed into a cylindrical module and then encased within a titanium housing. The non-condensed gas that is captured is then allowed to escape through a vent tube in the gas trap housing.
Technical Paper

Development of a Hydrophilic, Antimicrobial Coating for Condensing Heat Exchangers

1997-07-01
972408
Condensing heat exchangers (CHX) are used in many applications, including space life support systems, to control temperature and humidity. Temperature control is achieved by transfer of the heat load to a circulating coolant. Simultaneously, humidity control is provided by cooling the air below its dew point, and separating the condensed water from the gas flow. In space, the condensate does not drain from the heat exchanger because of the absence of gravity. To overcome this problem, slurping condensing heat exchangers have been developed that combine a hydrophilic coating on the air flow passages and an additional slurping section added to the air outlet of the heat exchanger to achieve efficient air-water separation. For short missions such as those typical for shuttle flights, microbial proliferation in the coatings has not been a major issue, despite the fact that the coatings are continuously moist and an ideal breeding ground for microbial species.
Technical Paper

Development of the Flame Detector for Space Station Freedom

1993-07-01
932106
One of the primary safety concerns for Space Station Freedom pressurized modules is fire. Some Freedom modules are unattended for long periods of time. In other cases, enclosed, pressurized volumes are not open to crew monitoring. As a result, a fire detection system is required to continuously monitor all modules for combustion. This paper briefly reviews the overall design for the Freedom fire detection system, and the design of the two basic types of detectors: smoke and flame. The smoke detectors monitor particulates in small open areas, stand-offs, end-cones, and racks. The flame detectors survey open areas for radiation at wavelengths and intensities characteristic of combustion. Responses from detectors are evaluated by Freedom's data management system to determine the presence of combustion and to recommend appropriate action.
X