Technical Paper

Thin-Film High Voltage Capacitors on Ultra-Thin Glass for Electric Drive Vehicle Inverter Applications

2014-04-01
2014-01-0417
The propulsion system in most Electric Drive Vehicles (EDVs) requires an internal combustion engine in combination with an alternating current (AC) electric motor. An electronic device called a power inverter converts battery DC voltage into AC power for the motor. The inverter must be decoupled from the DC source, so a large DC-link capacitor is placed between the battery and the inverter. The DC-link capacitors in these inverters negatively affect the inverters size, weight and assembly cost. To reduce the design/cost impact of the DC-link capacitors, low loss, high dielectric constant (κ) ferroelectric materials are being developed. Ceramic ferroelectrics, such as (Pb,La)(Zr,Ti)O3 [PLZT], offer high dielectric constants and high breakdown strength. Argonne National Laboratory and Delphi Electronics & Safety have been developing thin-film capacitors utilizing PLZT.
Technical Paper

A Non Traditional Solution for High Vibration Connection Systems

2014-04-01
2014-01-0221
As automotive and commercial vehicle OEM's continue their quest to reduce cost, product selection, quality, and reliability must be maintained. On-engine and wheel located connection systems create the greatest challenges due to the extreme levels of vibration. In the past, devices were fewer, and there where less direct connects in high vibration locations (Engine/ wheel sensors, electronic controllers, fuel injectors). Instead, small wire harnesses (“pigtails”) were commonly used. These pigtails can dampen the effect of the environment which includes mild to severe vibration by keeping the environmental effect away from the electrical connection contact point. Electrically connecting directly to the device creates new challenges in the connection system with the increased threat of fretting corrosion. Suppliers supporting OEM's are attempting to meet these direct connect requirements with lubrication, precious metal plating, and high contact force contacts.
Technical Paper

Post-Molding Crosslinking of Polyethylene in Automotive Connection Systems

2014-04-01
2014-01-1038
Twenty plies of low density polyethylene (LDPE) were stacked and irradiated with 200 kGy of 5 MeV electron beam. The plies were analyzed by Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA) for crosslink density using melting point depression and equilibrium storage modulus respectively. Infra-red spectroscopic analysis was conducted to examine the samples for the presence of chemical modification. The thermal stability of the irradiated samples and an unexposed control was investigated using Thermogravimetric Analysis (TGA). Results were utilized in assessing the viability of crosslinking products after the molding process to produce articles with improved resistance to temperature.
Technical Paper

Robust Thermal Design of a DC-DC Converter in an Electric Vehicle

2014-04-01
2014-01-0709
In hybrid electric vehicles (HEVs) and full electric vehicles (EVs), efficient electrical power management with proper supply of power at the required voltage levels is essential. A DC (Direct Current)-DC converter is one of the key electrical units in a HEV/EV. The DC-DC converter dealt in the present work is intended to create the DC voltages necessary to power the accessories. The electronic circuit in this DC-DC converter consists of high power devices like Metal-Oxide Semiconductor Field-Effect Transistors (MOSFETs), inductors, transformers, etc. mounted on a printed circuit board (PCB). The DC-DC converter interacts with a high voltage battery pack and supplies a low voltage power to the accessory battery. Due to this power handling operation, the devices in the convertor experience high temperatures. The temperature rise of the devices beyond the permissible limits could be detrimental to an efficient and safe operation of the converter.
Technical Paper

Integrated Front and Rear HVAC Unit

2014-04-01
2014-01-0690
Vehicles with a large cabin volume incorporate two HVAC units to provide comfort to the front and rear cabin. Each HVAC unit can generate independent airflow volume, temperature, and airflow direction. A new HVAC unit was developed to achieve the performance and functionality of two HVAC units. A unique HVAC construction was used to achieve independent front and rear airflow volume, temperature, and airflow direction distribution. This integrated front and rear HVAC unit provides additional packaging space for other vehicle components and reduces the overall number of HVAC system components.
Technical Paper

Force Distribution on Catalysts During Converter Assembly

2000-03-06
2000-01-0222
Thinwall substrates used in modern catalytic converters are more sensitive to assembly and operating forces. Various converter assembly processes are characterized using real time force transducer technology. The force distribution data from these assembly methods are presented. The analysis of this data leads to recommendations for packaging of converters depending on catalyst strength.