Evaluation of the Performance of the Thor-Alpha Dummy

2003-10-27
2003-22-0023
Six European laboratories have evaluated the biomechanical response of the new advanced frontal impact dummy THOR-alpha with respect to the European impact response requirements. The results indicated that for many of the body regions (e.g., shoulder, spine, thorax, femur/knee) the THOR-alpha response was close to the human response. In addition, the durability, repeatability and sensitivity for some dummy regions have been evaluated. Based on the tests performed, it was found that the THOR-alpha is not durable enough. The lack in robustness of the THOR-alpha caused a problem in completing the full test program and in evaluating the repeatability of the dummy. The results have demonstrated that the assessment of frontal impact protection can be greatly improved with a more advanced frontal impact dummy. Regarding biofidelity and injury assessment capabilities, the THOR-alpha is a good candidate however it needs to be brought up to standard in other areas.