Refine Your Search

Search Results

Viewing 1 to 4 of 4
Technical Paper

Driving with HID Headlamps: A Review of Research Findings

2003-03-03
2003-01-0295
High-intensity discharge (HID) headlamps have several advantages over tungsten-halogen headlamps, including greater light efficiency (lumens per watt) and longer life. However, from the safety point of view, the primary attraction of HID headlamps is that, because they produce more total light, they have the potential to provide more useful illumination to the driver. At the same time, there are concerns with the effects of HID illumination on perception of the colors of important objects and glare to oncoming traffic. This paper reviews research evidence that we have accumulated over the past 14 years concerning the potential benefits and drawbacks associated with the use of HID headlighting. We conclude that the evidence strongly supports the use of well-designed HID headlamps.
Technical Paper

Current Status and Future Prospects for Nonplanar Rearview Mirrors

2000-03-06
2000-01-0324
The Federal Motor Vehicle Safety Standards currently require driver-side rearview mirrors to be flat. For rearview mirrors of typical size, this requirement normally results in a blind zone on the driver side that is large enough to conceal an average size passenger car. In recent years a number of studies have suggested that nonplanar rearview mirrors may be an effective solution to this problem. This paper reviews the evidence on possible effectiveness of nonplanar mirrors, assesses the strength of that evidence, and makes tentative recommendations. The main conclusion is that the use of nonplanar mirrors would probably result in a net gain in safety, but that the effectiveness of the mirrors is likely to depend on details of how they are implemented. Issues that should be resolved by additional research (some of which is already underway) are: (1) How would U.S. drivers respond to a mixed fleet of vehicles, some of which had flat mirrors and some of which had nonplanar mirrors?
Technical Paper

Industrial Implementation of Practices for LDH Stability

1993-03-01
930816
The LDH (Limiting Dome Height Test) is widely used at Ford Motor Co. stamping plants laboratories to monitor the formability of incoming sheet materials. Although the LDH test is very easy to implement and interpret, variability of the results and poor reproducibility between laboratories limit its acceptance. In this investigation, some of the causes of variability and differences between plant laboratories are discussed. Much of the experimental work was done at plant laboratories and the results are directly applicable to quality control (QC) machines. It was found that the binder force and the binder shape have a big influence on the results, and they should be carefully controlled. The binder cleaning procedure is also relevant to the test variability. Punch temperature has a much greater influence on QC machines than on research machines and a method for controlling the punch temperature in QC machines is presented.
Technical Paper

A Research Design to Collect Data for a Second Generation Eyellipse

1975-02-01
750362
Current automotive design practices related to driver visibility are based on static laboratory studies of mostly straight ahead viewing that were conducted by Meldrum and others beginning in 1962. These individual studies have never been replicated either in the lab or in actual driving situations to determine the validity of their procedures. After a thorough review of the literature related to driver eye location and a statistical analysis of previous static eye location data, an experimental design is proposed to determine dynamic eye location distribution characteristics. This design will provide information on: (a) the relationship of static anthropometric measurements to dynamic eye location; (b) the difference between dynamic on-the-road eye location versus static in-the-lab eye location distributions: (c) the effect of different types of vehicle seating package parameters on eye location; and, (d) a validation of previous static eye location studies.
X