Refine Your Search

Search Results

Technical Paper

Results of the Third Long-Term Cycle at the University of Minnesota Aquifer Thermal Energy Storage (ATES) Field Test Facility

1992-08-03
929051
The third long-term ATES cycle (LT3) was conducted between October 1989 and March 1990. Objectives of LT3 were to demonstrate that high-temperature ATES could supply a real heating load and to simplify the water chemistry modeling. For LT3 the Field Test Facility (FTF) was connected to a nearby campus building to demonstrate the FTF's ability to meet a real heating load. For LT3 the wells were modified so that only the most permeable portions of the Ironton-Galesville aquifer were used to simplify water chemistry comparisons and modeling. The campus steam plant was the source for heat stored during LT3. A total volume of 63.2 x 103 m3 of water was injected at a rate of 54.95 m3/hr into the storage well at a mean temperature of 104.7°C from October through December 1989. Tie-in to the Animal Sciences Veterinary Medicine (ASVM) building was not completed until late December.
X