The thermal modeling guidelines and best practices provided in this document are applicable to powered aerospace vehicle wires and wire bundles in thermal environments ranging from -65 to +260 °C (-85 to +500 °F) and pressures ranging from sea level to space vacuum. Currently the ARP only considers steady state and direct current conditions. The effects of wiring terminations and connectors are not addressed. Both can significantly impact the overall current derating and safety margins for a wiring system.
Wire and cable products progress through a series of handling or operational steps from the time they leave the manufacturer, and until a finished harness or assembly is ready for installation on a vehicle. Throughout these many steps, environmental or processing conditions may be present which can generate damage detrimental to the wire or cable and/or its intended application.
This ARP specifies the recommended methods of marking electrical wiring and harnesses to aid in the positioning/routing of electrical wiring, harnesses and cable assemblies.