This specification establishes the requirements for various types and colors of electrical insulating sleeving that will shrink to a predetermined size upon the application of heat. This specification includes provisions for demonstrating compliance with qualification requirements (see Section 4 and 7.3), in process inspection, and statistical process control inspections (see 4.4). The continuous operating temperature ranges for the sleeving classes covered by this specification are from -112 to +482 °F (-80 to +250 °C). The continuous operating temperature range for each sleeving class is given in the applicable detail specification.
This specification covers 600 V heavy duty, portable, power, single and multiconductor, electrical cable for severe flexing service (see detail specifications for voltage limitations). The AS5756 insulation system has been used in aerospace ground power applications using 115/200 V (phase to neutral) at 400 Hz AC. Verification of the suitability of this product for use in other electrical system configurations (600 V, etc.) is the responsibility of the user.
This specification covers 600 V heavy duty, portable, power, single and multiconductor, electrical cable for severe flexing service (see detail specifications for voltage limitations). The AS5756 insulation system has been used in aerospace ground power applications using 115/200 V (phase to neutral) at 400 Hz AC. Verification of the suitability of this product for use in other electrical system configurations (600 V, etc.) is the responsibility of the user.