Refine Your Search

Topic

Search Results

Standard

Laser Wire Stripping Tools, General Understanding

2022-08-26
CURRENT
AIR6894A
This SAE Aerospace Information Report (AIR) describes laser wire stripping technologies and recommendations to strip electrical single conductor wires and shielded cables intended for aerospace applications. These recommendations include: Laser types for wire stripping Laser stripping system configuration Quality assurance Tool qualification Tool inspection User health and safety
Standard

Dimensional Life of Heat-Shrinkable Sleeve

2022-05-02
CURRENT
AIR7930
This SAE Aerospace Information Report provides additional information and background in regard to the dimensional life of a heat-shrinkable sleeve. The term dimensional life is newly introduced in AS23053 to relate to the dimensional stability instead of the material stability often associated or referred to as the “shelf life.” When the material exceeds such shelf life, it becomes harmful or non-functional.
Standard

Cable, Electric, Filter Line, Radio Frequency Absorptive

2021-06-22
CURRENT
AS85485D
This specification covers the requirements for radio frequency absorptive component wires and finished cables which function electrically as distributed low-pass filters. Materials and construction details are specified in the detail specification.
Standard

Cable, Electric, Filter Line, Radio Frequency Absorptive

2021-03-05
HISTORICAL
AS85485C
This specification covers the requirements for radio frequency absorptive component wires and finished cables which function electrically as distributed low-pass filters. Materials and construction details are specified in the detail specification.
Standard

Impact of High Voltage on Wiring

2021-02-11
CURRENT
AIR7506
This SAE Aerospace Informatino Report (AIR) focuses on how long-term exposure of high voltage below and above wire insulation corona inception voltage (CIV) impacts round wire insulation life. This AIR will be updated when additional data is available.
Standard

Wire, Electrical, Stranded, Uninsulated Copper, Copper Alloy, or Aluminum, or Thermocouple Extension, General Specification for

2020-09-01
HISTORICAL
AS29606A
This specification covers concentric lay stranded and rope-lay stranded round electrical conductor fabricated from copper, copper alloy or aluminum. This specification also covers thermocouple extension conductor fabricated from nickel/chromium or nickel/aluminum/manganese. The conductors in this specification are suitable for use in insulated wires used in aerospace and other applications.
Standard

Fluoride Offgassing in Fluoropolymer Insulations

2020-03-24
CURRENT
ARP6229
This SAE Aerospace Recommended Practice (ARP) shall be limited to information about corrosion caused by fluoride offgassing of fluoropolymer-based wire insulation. It reviews published reports of corrosion caused by this phenomenon, describes scenarios where this may be a concern, mitigation options, and references a test method which can be used to evaluate wire insulations where needed.
Standard

Test Methods for Insulated Electric Wire

2020-03-12
CURRENT
AS4373F
This standard describes test methods for insulated, single conductor, electric wire intended for aerospace applications. Particular requirements for the wire being tested need to be specified in a procurement document or other detail specification. Suggested minimum requirements are included in the notes at the end of some of the test methods. SAE Performance Standard AS4372 uses some of the tests in this document for evaluating comparative performance of aerospace wires.
Standard

Sleeve, Protection, for Cable and Harness Protection

2019-10-03
CURRENT
AS60491A
Procurement specification is principally for defining protection sleeves on a cable or group of electrical/fiber optic wires (wiring bundle). Single wire protection depends on the minimum diameter of the wire. Sleeve may be used to protect a wire bundle for a platform installation or for repair of installed damaged jacket or jacket/shielded wire bundles. Refer to AS50881 for aerospace wire bundle protection installations.
Standard

Investigation of Silver-Plated Conductor Corrosion (Red Plague)

2019-10-02
CURRENT
AIR4487B
This SAE Aerospace Information Report (AIR) shall be limited to information about a specific corrosion mechanism of silver-plated conductors that produces cuprous/cupric oxide deposits (Red Plague). It examines some possible causes and some recommendations to minimize the possibility of its occurrence. It also provides a number of reference documents that describe the corrosion in detail, methods to determine conductor damage, methods to produce the corrosion, and other investigative reports of this phenomena and their conclusions.
Standard

Cable, Electric, Filter Line, Radio Frequency Absorptive

2017-11-08
HISTORICAL
AS85485B
This specification covers the requirements for radio frequency absorptive component wires and finished cables which function electrically as distributed low-pass filters. Materials and construction details are specified in the detail specification.
Standard

Insulation Sleeving, Electrical, Heat Shrinkable, General Specification For

2016-10-16
HISTORICAL
AS23053
This specification establishes the requirements for various types and colors of electrical insulating sleeving that will shrink to a predetermined size upon the application of heat. This specification includes provisions for demonstrating compliance with qualification requirements (see Section 4 and 7.3), in process inspection, and statistical process control inspections (see 4.4). The continuous operating temperature ranges for the sleeving classes covered by this specification are from -112 to +482 °F (-80 to +250 °C). The continuous operating temperature range for each sleeving class is given in the applicable detail specification.
Standard

Sleeve, Protection, For Cable and Harness Protection

2015-12-02
HISTORICAL
AS60491
Procurement specification is principally for defining protection sleeves on a cable or group of electrical/fiber optic wires (wiring bundle). Single wire protection depends on the minimum diameter of the wire. Sleeve may be used to protect a wire bundle for a platform installation or for repair of installed damaged jacket or jacket/shielded wire bundles. See AS50881 for aerospace wire bundle protection installations.
X