Standard

Standard for 12 Volt Cigarette Lighters, Power Outlets, and Accessory Plugs

2009-02-05
CURRENT
J563_200902
This standard is intended to cover cigar or cigarette lighters as well as power outlets based on the form and dimensions of the cigar lighter, and accessory plugs for use in these devices. Components covered herein are designed to work in nominal 12 VDC systems. This standard is a full performance specification. It includes dimensional and operational parameters as well as performance characteristics which must be met when submitting a cigar lighter assembly, power outlet assembly, or plug for production approval. This standard constitutes an acceptance specification for these devices. This standard covers the operational, reliability, durability, acceptance, and testing requirements for a cigar lighter (also referred to as just “lighter”) for installation in the passenger compartment of production vehicles.
Standard

Blade Fuses - 42 V System

2002-04-24
CURRENT
J2576_200204
This SAE Recommended Practice defines the blade fuse styles, test conditions, procedures, and performance requirements for use in vehicle electrical power systems designed to the new motor vehicle industry 42 V architecture. The intent of this document is to provide a framework for 58 V Blade Fuse characteristics, serving the motor vehicle industry to establish standardization with respect to electrical performance and mechanical requirements. This standardization shall lend itself to safe application practices; e.g., prevention of 32 V devices utilized inappropriately in 42 V electrical systems. Both the performance and mechanical requirements expressed herein are for the advancement of mobility engineering and the development of safe application practices. They are not intended for the establishment of design exclusions, patent rights, or franchising that engenders restraint of trade.
Standard

Plug-In Relay Test Methods

2000-09-07
CURRENT
J2544_200009
This SAE Standard covers standard test methods for environmental, mechanical, and electrical testing of plug-in relays used in surface vehicle electrical systems.
Standard

FLASHERS

1996-08-01
CURRENT
J1690_199608
This SAE Recommended Practice defines the test conditions, procedures, and minimum design requirements for nominal 6, 12, and 24 V turn signal, hazard warning, warning lamp alternating, and combination flashers.
Standard

WARNING LAMP ALTERNATING FLASHERS

1994-09-01
HISTORICAL
J1054_199409
This SAE Recommended Practice defines the test conditions, procedures, and minimum design requirements for nominal 6,12, and 24 V warning lamp alternating flashers.
Standard

DOOR COURTESY SWITCH

1991-12-01
CURRENT
J2108_199112
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for 6, 12, and 24 V Door Courtesy Switches which are intended for use in motor vehicles.
Standard

DOOR COURTESY SWITCH

1991-06-01
HISTORICAL
J2108_199106
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for 6, 12, and 24 V Door Courtesy Switches which are intended for use in motor vehicles.
Standard

HIGH CURRENT TIME LAG ELECTRIC FUSES

1990-11-01
CURRENT
J1888_199011
The fuses shown in Figure 1 are for use in motor vehicles, boats, and trailers to protect electrical wiring. This SAE Standard is for the construction shown and is not intended to restrict the design and use of other configurations and materials capable of meeting the vehicle requirements.
Standard

MINIATURE BLADE TYPE ELECTRICAL FUSES

1990-11-01
CURRENT
J2077_199011
The fuses shown in Figure 1 are for use in motor vehicles, boats, and trailers to protect electrical wiring and equipment. This SAE Standard is for the construction shown and is not intended to restrict the design and use of other configurations and materials capable of meeting the vehicle requirements.
Standard

BACKUP LAMP SWITCH

1990-03-16
CURRENT
J1076_199003
This standard defines the test conditions, procedures and performance specification for 6, 12, and 24 V backup lamp switches which are intended for use in motor vehicles.
Standard

HEADLAMP BEAM SWITCHING

1990-03-16
CURRENT
J564_199003
This SAE Standard defines the test conditions, procedures and performance specification for 6, 12, and 24 V manually actuated headlamp beam control switches.
Standard

WARNING LAMP ALTERNATING FLASHERS

1989-10-01
HISTORICAL
J1054_198910
This document defines the test conditions, procedures, and minimum design requirements for nominal 6, 12, and 24 V warning lamp alternating flashers.
Standard

HAZARD WARNING SIGNAL SWITCH

1988-10-01
CURRENT
J910_198810
This standard defines the test conditions, procedures and performance specifications for 6, 12 and 24-V manually actuated hazard warning signal switch.
Standard

MECHANICAL STOP LAMP SWITCH

1988-06-01
CURRENT
J249_198806
The mechanical stop lamp switch is an operator activated mechanical device intended primarily to control the functioning of the stop lamp and high mounted stop lamp circuits. Secondarily, the device may control the functioning of various accessories, such as disengaging cruise control, with operator actuation of brake pedal.
Standard

BLADE TYPE ELECTRIC FUSES

1988-04-01
CURRENT
J1284_198804
The fuses shown are for use in motor vehicles, boats, and trailers to protect electrical wiring and equipment. This standard is for the construction shown and is not intended to restrict the design and use of other configurations and materials capable of meeting the vehicle requirements.
Standard

ELECTRIC FUSES (CARTRIDGE TYPE)

1987-08-01
CURRENT
J554_198708
The fuses shown are for use in motor vehicles, boats, and trailers to protect electrical wiring and equipment. This standard is for the construction shown and is not intended to restrict the design and use of other configurations and materials capable of meeting the vehicle requirements.
Standard

TURN SIGNAL FLASHERS

1986-07-01
HISTORICAL
J590_198607
This recommended practice defines the test conditions, procedures and minimum design requirements for nominal 6, 12 and 24 volt turn signal flashers.