Refine Your Search

Search Results

Viewing 1 to 12 of 12
Technical Paper

Reduction in the Iodine Content of Shuttle Drinking Water: Lessons Learned

1999-07-12
1999-01-2117
Iodine is the disinfectant used in U.S. spacecraft potable water systems. Recent long-term testing on human subjects has raised concerns about excessive iodine consumption. Efforts to reduce iodine consumption by Shuttle crews were initiated on STS-87, using hardware originally designed to deiodinate Shuttle water prior to transfer to the Mir Space Station. This hardware has several negative aspects when used for Shuttle galley operations, and efforts to develop a practical alternative were initiated under a compressed development schedule. The alternative Low Iodine Residual System (LIRS) was flown as a Detailed Test Objective on STS-95. On-orbit, the LIRS imparted an adverse taste to the water due to the presence of trialkylamines that had not been detected during development and certification testing. A post-flight investigation revealed that the trialkylamines were released during gamma sterilization of the LIRS resin materials.
Technical Paper

Humidity Condensate Sampling System for Shuttle, Mir and International Space Station

1998-07-13
981764
Archival sampling of potable water and condensate for ground laboratory analysis has been an important part of the Shuttle-Mir program because of coolant leaks and other events on Mir that have affected water quality. We report here the development of and preliminary results from a novel device for single phase humidity condensate collection at system pressures. The sampler consists of a commercial-off-the-shelf Teflon® bladder and a custom reinforced Nomex® restraint that is sized properly to absorb the stress of applied pressures. A plastic Luer-Lock disconnect, with poppet actuated by a mating Luer-Lock fitting, prevents the contents from being spilled during transport. In principle, a sampler of any volume can be designed. The empty mass of the reusable one-liter sampler is only 63 grams. Several designs were pressure tested and found to withstand more than 3 atmospheres well in excess of typical spacecraft water or wastewater system pressures.
Technical Paper

Chemical Analysis of Potable Water and Humidity Condensate Collected During the MIR-21 Mission

1997-07-01
972462
The primary source of potable water planned for the International Space Station will be generated from the reclamation of humidity condensate, urine, and hygiene waters. It is vital to crew health and performance that this reclaimed water be safe for human consumption, and that health risks associated with recycled water consumption be identified and quantified. Only recently has data been available on the chemical constituents in reclaimed waters generated in microgravity. Results for samples collected during Mir-21 reveal that both the reclaimed water and stored water are of potable quality, although the samples did not meet U.S. standards for total organic carbon (TOC), total phenols, and turbidity.
Technical Paper

Potable Water Treatment and Transfer from Shuttle to Mir

1997-07-01
972461
To satisfy a requirement to supply water to Mir station, a process for treating iodinated water on the Shuttle was developed and implemented. The treatment system consists of packed columns for removing iodine and a syringe-based injection system for adding ionic silver, the biocide used in Mir water. Technical and potable grade water is produced and transferred in batches using collapsible 44-liter contingency water containers (CWCs). Silver is added to the water via injection of a solution from preloaded syringes. Minerals are also added to water destined for drinking. During the previous four Shuttle-Mir docking missions a total of 2781 liters (735 gallons) of water produced by the Shuttle fuel cells was processed using this method and transferred to Mir. To verify the quality of the processed water, samples were collected during flight and returned for chemical analysis.
Technical Paper

Water Analysis Results from Phase II of the NASA Early Human Testing Initiative 30-Day Closed Chamber Test

1997-07-01
972555
An important milestone in the ongoing effort by NASA to develop and refine closed-loop water recycling systems for human space flight was reached during the summer of 1996 with the successful completion of Phase II of the Lunar Mars Life Support Testing Program at Johnson Space Center. Part of Phase II involved testing a water-recycling system in a closed test chamber continuously occupied by four human subjects for thirty days. The Phase II crew began the test with a supply of water that had been processed and certified for human use. As the test progressed, humidity condensate, urine, and wastewater from personal hygiene and housekeeping activities were reclaimed and reused several times. Samples were collected from various points in the reclamation process during the thirty day test. The data verified the water-processing hardware can reliably remove wastewater contaminants and produce reclaimed water that meets NASA standards for hygiene- and potable-quality water.
Technical Paper

Microbiological Analysis of Water in Space

1995-07-01
951683
One of the proposed methods for monitoring the microbial quality of the water supply aboard the International Space Station is membrane filtration. We adapted this method for space flight by using an off-the-shelf filter unit developed by Millipore. This sealed unit allows liquid to be filtered through a 0.45 μm cellulose acetate filter that sits atop an absorbent pad to which growth medium is added. We combined a tetrazolium dye with R2A medium to allow microbial colonies to be seen easily, and modified the medium to remain stable over 70 weeks at 25°C. This hardware was assembled and tested in the laboratory and during parabolic flight; a modified version was then flown on STS-66. After the STS-66 mission, a back-up plastic syringe and an all-metal syringe pump were added to the kit, and the hardware was used successfully to evaluate water quality aboard the Russian Mir space station.
Technical Paper

GC/MS and CE Methods for the Analysis of Trace Organic Acids in Reclaimed Water Supplies

1994-06-01
941392
The objective of this study was to investigate combining GC/MS and CE methods to allow sub-mg/L levels of organic acids to be determined in various water samples. This study also served as a basis for evaluating these instruments for in-flight spacecraft water-quality monitoring and to help determine the modifications needed to convert terrestrial hardware for use in microgravity environments. This paper reports on current GC/MS and CE method development and data generated from some recent spacecraft-related water samples. Plans for further method development are also discussed.
Technical Paper

Advanced Development of the Regenerative Microbial Check Valve

1993-07-01
932175
The Microbial Check Valve (MCV) is a reloadable flow-through canister containing iodinated ion exchange resin, which is used aboard the Shuttle Orbiter as a disinfectant to maintain water potability. The MCV exhibits a significant contact kill and imparts a biocidal residual I2 concentration to the effluent. MCVs in current use have nominal 30 day lives. MCVs baselined for Space Station Freedom will have 90 day lives, and will require replacement 120 times over 30 years. Means to extend MCV life are desirable to minimize resupply penalties. New technology has been developed for fully autonomous in situ regeneration of an expended MCV canister. The Regenerative Microbial Check Valve (RMCV) consists of an MCV, a packed bed of crystalline I2, a flow diverter valve, an in-line iodine monitor and a microcontroller. During regeneration, flow is directed first through the packed I2 bed and then into the MCV where the resin is replenished.
Technical Paper

Electrochemical Ozone Generator for In Situ Sterilization of Potable Water and Wastewater

1993-07-01
932177
Disinfection of water and wastewater was proven to be feasible using a Breadboard Electrochemical Ozone Generator (EOG). A static gas/liquid separator, containing a microporous, hydrophobic membrane, was tested with the Breadboard EOG, and was found to increase the concentration of the ozone (O3) dissolved in the water. Distilled water and selected wastewaters were disinfected, achieving dissolved O3 concentrations up to 3 mg/L. The hardware is capable of operating in 0-g and 1-g environments. An end-item Electrochemical Ozonator (EO), sized to disinfect 116 kg of potable water per day, was projected to weigh 1.2 kg and consume only 18.5 W.
Technical Paper

Characterization of Spacecraft Humidity Condensate

1993-07-01
932176
When construction of Space Station Freedom reaches the Permanent Manned Capability stage, plans call for the Water Recovery and Management Subsystem to treat distilled urine, spent hygiene water, and humidity condensate in order to reclaim water of potable quality. The reclamation technologies currently baselined to process these wastewaters include adsorption, ion exchange, catalytic oxidation, and disinfection. To ensure that baselined technologies will be able to effectively remove those compounds that present health risks to the crew, the National Research Council has recommended that additional information be gathered on specific contaminants in wastewaters representative of those to be encountered on Space Station. This paper reports the efforts by the Water and Food Analytical Laboratory at the Johnson Space Center to enlarge the database of potential contaminants in humidity condensate.
Technical Paper

Chemistry and Kinetics of I2 Loss in Urine Distillate and Humidity Condensate

1992-07-01
921314
A significant decline in molecular iodine concentration is associated with the iodination of heavily contaminant-laden process water streams such as humidity condensate and urine distillate. Iodine loss is attributable to the reaction of this biocide with organic constituents. This phenomenon has been investigated using time resolved molecular absorption spectrophotometry of iodinated ersatz humidity condensates and iodinated ersatz urine distillates across the ultraviolet and visible spectral regions. Rates of iodine loss have also been studied using single contaminant systems at equivalent concentrations. The predominant reactive species have been identified as thiourea and formic acid. Pseudo-first order rate constants have been determined for ersatz contaminant model mixtures and for individual reactive constituents. Second order rate constants have been determined for the bimolecular reaction of iodine and formic acid.
Technical Paper

Space Station Environmental Health System Water Quality Monitoring

1990-07-01
901351
One of the unique aspects of the Space Station is that it will be a totally encapsulated environment and the air and water supplies will be reclaimed for reuse. The Environmental Health System, a subsystem of CHeCS (Crew Health Care System), must monitor the air and water on board the Space Station Freedom to verify that the quality is adequate for crew safety. Specifically, the Water Quality Subsystem will analyze the potable and hygiene water supplies regularly for organic, inorganic, particulate, and microbial contamination. The equipment selected to perform these analyses will be commercially available instruments which will be converted for use on board the Space Station Freedom. Therefore, the commercial hardware will be analyzed to identify the gravity dependent functions and modified to eliminate them.
X