Refine Your Search

Affiliation

Search Results

Technical Paper

THOR-05F Response in Sled Tests Inducing Submarining and Comparison with PMHS Response Corridors

2022-05-20
2021-22-0005
The Test Device for Human Occupant Restraint (THOR) is an advanced crash test dummy designed for frontal impact. Originally released in a 50th percentile male version (THOR-50M), a female 5th version (THOR-05F) was prototyped in 2017 (Wang et al., 2017) and compared with biofidelity sub-system tests (Wang et al., 2018). The same year, Trosseille et al. (2018) published response corridors using nine 5th percentile female Post Mortem Human Subjects (PMHS) tested in three sled configurations, including both submarining and non-submarining cases. The goal of this paper is to provide an initial evaluation of the THOR-05F biofidelity in a full-scale sled test, by comparing its response with the PMHS corridors published by Trosseille et al. (2018). Significant similarities between PMHS and THOR-05F were observed: as in Trosseille et al. (2018), the THOR-05F did not submarine in configuration 1, and submarined in configurations 2 and 3.
Technical Paper

The Effects of Small Seat Swiveling Angles on Occupant Responses during a Frontal Impact

2020-04-14
2020-01-0571
In highly automated vehicles (HAVs), new seat configurations may be desirable to allow occupants to perform new activities. One of the current HAV concepts is the swiveled seat layout, which might facilitate communication between occupants. The main objective of this study was to investigate the effects of seat swiveling angles on occupant kinematics and injury risk predicted by a Human Body Model (HBM) during a frontal impact. A detailed 50th percentile male HBM (GHBMC M50-O) was subjected to two frontal crash pulses in a sled setup. The model was positioned on a semi-rigid seat and restrained using a pre-inflated airbag and a three-point seatbelt. Simulations included four seat swiveling angles (0, -10, -20, and -30 degrees), three occupant positions (Sedan driver, large VAN driver or Laptop user), two airbag initial locations (nominal or matching the head Y location), and the inclusion of lateral supports on the seat pan.
Technical Paper

Assessment of Several THOR Thoracic Injury Criteria based on a New Post Mortem Human Subject Test Series and Recommendations

2020-03-31
2019-22-0012
Several studies, available in the literature, were conducted to establish the most relevant criterion for predicting the thoracic injury risk on the THOR dummy. The criteria, such as the maximum deflection or a combination of parameters including the difference between the chest right and left deflections, were all developed based on given samples of Post Mortem Human Subject (PMHS). However, they were not validated against independent data and they are not always consistent with the observations from field data analysis. For this reason, 8 additional PMHS and matching THOR tests were carried out to assess the ability of the criteria to predict risks. Accident investigations showed that a reduction of the belt loads reduces the risk of rib fractures. Two configurations with different levels of force limitation were therefore chosen. A configuration representing an average European vehicle was chosen as a reference.
Technical Paper

Far Side Impact Injury Threshold Recommendations Based on 6 Paired WorldSID / Post Mortem Human Subjects Tests

2020-03-31
2019-22-0005
Far side has been identified in the literature as a potential cause of numerous injuries and fatalities. Euro NCAP developed a far side test protocol to be performed to assess adult protection. A monitoring phase was undertaken between January 2018 and December 2019, and the far side assessment will become part of the rating for all vehicles launched in 2020 onward. A test buck was developed and 6 paired WorldSID / Post Mortem Human Subjects (PMHS) were subjected to the test protocol proposed by Euro NCAP to contribute to the development of limits. The buck consisted of a rigid seat and a rigid central console covered with 50 mm of Ethafoam TM 180 with a density of 16 kg/m3. The buck was mounted on the sled with an angle of 75° between the X axis of the vehicle and the X axis of the sled. The peak head excursion was compared between PMHS and the WorldSID dummy. It was found reasonably similar. However, the dummy repeatability was found to be poor.
Technical Paper

Reference PMHS Sled Tests to Assess Submarining of the Small Female

2018-11-12
2018-22-0003
In the last decade, extensive efforts have been made to understand the physics of submarining and its consequences in terms of abdominal injuries. For that purpose, 27 Post Mortem Human Subject (PMHS) tests were performed in well controlled conditions on a sled and response corridors were provided to assess the biofidelity of dummies or human body models. All these efforts were based on the 50th percentile male. In parallel, efforts were initiated to transfer the understanding of submarining and the prediction criteria to the THOR dummies. Both the biofidelity targets and the criteria were scaled down from the 50th percentile male to the 5th percentile THOR female. The objective of this project was to run a set of reference PMHS tests in order to check the biofidelity of the THOR F05 in terms of submarining. Three series of tests were performed on nine PMHS, the first one was designed to avoid submarining, the second and third ones were designed to result in submarining.
Technical Paper

Relation Between Sacroilium and Other Pelvic Fractures Based on Real-World Automotive Accidents

2018-11-12
2018-22-0010
The study firstly aimed at looking whether sacroilium (SI) fractures could be sustained as unique pelvic injuries in side impact real world automotive accidents. Secondarily, the sacroilium fractures observed in conjunction with other pelvic fractures were analyzed to investigate the existence of injury association patterns. Two real world accident databases were searched for SI fractures. The occupants selected were front car passengers older than 16, involved in side, oblique or frontal impact, with AIS2+ pelvic injuries. In frontal impact, only the belted occupants were selected. The cases were sorted by the principal direction of force (dof) and the type of pelvic injury, namely SI, pubic rami, iliac wing, acetabulum, pubic symphysis, and sacrum injuries. The relation between SI and pubic rami injuries were investigated first. The first database is an accident database composed of cases collected in France by car manufacturers over a period of approximately 40 years.
Technical Paper

Update of the WorldSID 50th Male Pelvic Injury Criterion and Risk Curve

2018-04-03
2018-01-0539
Petit et al. 2015 and Lebarbé et al. 2016 reported on two studies where the injury mechanism and threshold of the sacroiliac joint were investigated in two slightly oblique crash test conditions from 18 Post Mortem Human Subjects (PMHS) tests. They concluded that the sacroiliac joint fractures were associated with pubic rami fractures. These latter being reported to occur first in the time history. Therefore it was recommended not to define a criterion specific for the sacroiliac joint. In 2012, injury risk curves were published for the WorldSID dummy by Petitjean et al. For the pelvis, dummy and PMHS paired tests from six configurations were used (n = 55). All of these configurations were pure lateral impacts. In addition, the sacroiliac joint and femur neck loads were not recorded, and the dummy used was the first production version (WorldSID revision 1). Since that time, the WorldSID was updated several times, including changes in the pelvis area.
Technical Paper

Investigation of Pelvic Injuries on Eighteen Post Mortem Human Subjects Submitted to Oblique Lateral Impacts

2016-11-07
2016-22-0005
The aim of this study was to investigate the sacroiliac joint injury mechanism. Two test configurations were selected from full scale car crashes conducted with the WorldSID 50th dummy resulting in high sacroiliac joint loads and low pubic symphysis force, i.e. severe conditions for the sacroiliac joint. The two test conditions were reproduced in laboratory using a 150-155 kg guided probe propelled respectively at 8 m/s and 7.5 m/s and with different shapes and orientations for the plate impacting the pelvis. Nine Post Mortem Human Subject (PMHS) were tested in each of the two configurations (eighteen PMHS in total). In order to get information on the time of fracture, eleven strain gauges were glued on the pelvic bone of each PMHS. Results - In the first configuration, five PMHS out of nine sustained AIS2+ pelvic injuries. All five presented sacroiliac joint injuries associated with pubic area injuries.
Technical Paper

Proposed Method for Development of Small Female and Midsize Male Thorax Dynamic Response Corridors in Side and Forward Oblique Impact Tests

2015-11-09
2015-22-0007
Despite the increasing knowledge of the thorax mechanics, the effects of inter-individual differences on the mechanical response are difficult to take into account. Several methods are available in the literature to refine the biofidelity corridors or to extrapolate them to other populations (eg: children, small females, large males). Because of the lack of concrete cases, the relevance of the assumptions is rarely investigated. In 2014, Baudrit et al. published data on thorax dynamic responses of small female and midsize male Post Mortem Human Subjects in side and forward oblique impact tests. The impactor mass was 23.4 kg for all the tests and the nominal impact speed was 4.3 m/s. The diameter of the rigid disk was 130 and 152 mm respectively for the small female specimens and for the midsize male specimens. The authors found that the maximum impact force was a function of the total body mass for each loading.
Technical Paper

Reference PMHS Sled Tests to Assess Submarining

2015-11-09
2015-22-0008
Sled tests focused on pelvis behavior and submarining can be found in the literature. However, they were performed either with rigid seats or with commercial seats. The objective of this study was to get reference tests to assess the submarining ability of dummies in more realistic conditions than on rigid seat, but still in a repeatable and reproducible setup. For this purpose, a semi-rigid seat was developed, which mimics the behavior of real seats, although it is made of rigid plates and springs that are easy to reproduce and simulate with an FE model. In total, eight PMHS sled tests were performed on this semi-rigid seat to get data in two different configurations: first in a front seat configuration that was designed to prevent submarining, then in a rear seat configuration with adjusted spring stiffness to generate submarining. All subjects sustained extensive rib fractures from the shoulder belt loading.
Technical Paper

A Comparison of Sacroiliac and Pubic Rami Fracture Occurrences in Oblique Side Impact Tests on Nine Post Mortem Human Subjects

2015-11-09
2015-22-0002
The WorldSID dummy can be equipped with both a pubic and a sacroiliac joint (S-I joint) loadcell. Although a pubic force criterion and the associated injury risk curve are currently available and used in regulation (ECE95, FMVSS214), as of today injury mechanisms, injury criteria, and injury assessment reference values are not available for the sacroiliac joint itself. The aim of this study was to investigate the sacroiliac joint injury mechanism. Three configurations were identified from full-scale car crashes conducted with the WorldSID 50th percentile male where the force passing through the pubis in all three tests was approximately 1500 N while the sacroiliac Fy / Mx peak values were 4500 N / 50 Nm, 2400 N / 130 Nm, and 5300 N / 150 Nm, respectively. These tests were reproduced using a 150 kg guided probe impacting Post Mortem Human Subjects (PMHS) at 8 m/s, 5.4 m/s and 7.5 m/s.
Technical Paper

The Effect of Upper Body Mass and Initial Knee Flexion on the Injury Outcome of Post Mortem Human Subject Pedestrian Isolated Legs

2014-11-10
2014-22-0008
In the ECE 127 Regulation on pedestrian leg protection, as well as in the Euro NCAP test protocol, a legform impactor hits the vehicle at the speed of 40 kph. In these tests, the knee is fully extended and the leg is not coupled to the upper body. However, the typical configuration of a pedestrian impact differs since the knee is flexed during most of the gait cycle and the hip joint applies an unknown force to the femur. This study aimed at investigating the influence of the inertia of the upper body (modelled using an upper body mass fixed at the proximal end of the femur) and the initial knee flexion angle on the lower limb injury outcome. In total, 18 tests were conducted on 18 legs from 9 Post Mortem Human Subjects (PMHS). The principle of these tests was to impact the leg at 40 kph using a sled equipped with 3 crushing steel tubes, the stiffness of which were representative of the front face of a European sedan (bonnet leading edge, bumper and spoiler).
Technical Paper

Comparison of the Thorax Dynamic Responses of Small Female and Midsize Male Post Mortem Human Subjects in Side and Forward Oblique Impact Tests

2014-11-10
2014-22-0004
Despite the increasing knowledge of the thorax mechanics in impact loadings, the effects of inter-individual differences on the mechanical response are difficult to take into account. For example, the biofidelity corridors for the small female or large male are extrapolated from the midsize male corridors. The present study reports on the results of new tests performed on small female Post Mortem Human Subjects (PMHS), and compares them with test results on midsize male PMHS. Three tests in pure side impact and three tests in forward oblique impact were performed on the thorax of small female specimens. The average weight and stature were 43 kg and 1.58 m for the small female specimens. The initial speed of the impactor was 4.3 m/s. The mass and the diameter of the impactor face were respectively 23.4 kg and 130 mm. The instrumentation and methodology was the same as for the tests published in 2008 by Trosseille et al. on midsize male specimens.
Technical Paper

Abdominal Twin Pressure Sensors for the Assessment of Abdominal Injuries in Q Dummies: In-Dummy Evaluation and Performance in Accident Reconstructions

2012-10-29
2012-22-0010
The Abdominal Pressure Twin Sensors (APTS) for Q3 and Q6 dummies are composed of soft polyurethane bladders filled with fluid and equipped with pressure sensors. Implanted within the abdominal insert of child dummies, they can be used to detect abdominal loading due to the belt during frontal collisions. In the present study - which is part of the EC funded CASPER project - two versions of APTS (V1 and V2) were evaluated in abdominal belt compression tests, torso flexion test (V1 only) and two series of sled tests with degraded restraint conditions. The results suggest that the two versions have similar responses, and that the pressure sensitivity to torso flexion is limited. The APTS ability to detect abdominal loading in sled tests was also confirmed, with peak pressures typically below 1 bar when the belt loaded only the pelvis and the thorax (appropriate restraint) and values above that level when the abdomen was loaded directly (inappropriate restraint).
Technical Paper

Kinematics and Dynamics of the Pelvis in the Process of Submarining using PMHS Sled Tests

2012-10-29
2012-22-0011
This study focused on a better understanding and characterization of the submarining phenomenon that occurs in frontal crashes when the lap belt slides over the anterior superior iliac spine. Submarining is the consequence of the pelvis kinematics relative to the lap belt, driven by the equilibrium of forces and moments applied to the pelvis. The study had two primary purposes; the first was to provide new PMHS data in submarining test configurations, the second was to investigate the Hybrid II and Hybrid III dummies biofidelity regarding submarining. Several Post Mortem Human Subject (PMHS) studies have been published on this subject. However, the lack of information about the occupant initial positioning and the use of car seats make it difficult to reconstruct these tests. Furthermore, the two dummies are rarely compared to PMHS in submarining test configurations. A fifteen frontal sled test campaign was carried out on two Anthropomorphic Test Devices (ATDs) and nine PMHS.
Technical Paper

Injury Risk Curves for the WorldSID 50th Male Dummy

2012-10-29
2012-22-0008
The development of the WorldSID 50th percentile male dummy was initiated in 1997 by the International Organisation for Standardisation (ISO/TC22/SC12/WG5) with the objective of developing a more biofidelic side impact dummy and supporting the adoption of a harmonised dummy into regulations. The dummy is currently under evaluation at the Working Party on Passive Safety (GRSP) in order to be included in the pole side impact global technical regulation (GTR). Injury risk curves dedicated to this dummy and built on behalf of ISO/TC22/SC12/WG6 were proposed in order to assess the occupant safety performance (Petitjean et al. 2009). At that time, there was no recommendation yet on the injury criteria and no consensus on the most accurate statistical method to be used. Since 2009, ISO/TC22/SC12/WG6 reached a consensus on the definition of guidelines to build injury risk curves, including the use of the survival analysis, the distribution assessment and quality checks.
Technical Paper

Study of Rib Fracture Mechanisms Based on the Rib Strain Profiles in Side and Forward Oblique Impact

2011-11-07
2011-22-0009
Rib fractures constitute a good indication of severity as there are the most frequent type of AIS3+ chest injuries. In 2008, Trosseille et al. showed a promising methodology to exhibit the rib fracture mechanisms, using strain gauges glued on the ribs of Post-Mortem Human Subjects (PMHS) and developing a specific signal analysis. In 2009, they published the results of static airbag tests performed on 50th percentile male PMHS at different distances and angles (pure lateral and 30 degrees forward oblique direction). To complete these already published data, a set of 8 PMHS lateral and oblique impactor tests were performed with the same methodology. The rib cages were instrumented with more than 100 strain gauges on the ribs, cartilage and sternum. A 23.4 kg impactor was propelled at 4.3 or 6.7 m/s. The forces applied onto the PMHS at 4.3 m/s ranged from 1.6 kN to 1.9 kN and the injuries varied from 4 to 13 rib fractures.
Technical Paper

Statistical Simulations to Evaluate the Methods of the Construction of Injury Risk Curves

2011-11-07
2011-22-0015
Several statistical methods are currently used to build injury risk curves in the biomechanical field. These methods include the certainty method (Mertz et al. 1996), Mertz/Weber method (Mertz and Weber 1982), logistic regression (Kuppa et al. 2003, Hosmer and Lemeshow 2000), survival analysis with Weibull distribution (Kent et al. 2004, Hosmer and Lemeshow 2000), and the consistent threshold estimate (CTE) (Nusholtz et al. 1999, Di Domenico and Nusholtz 2005). There is currently no consensus on the most accurate method to be used and no guidelines to help the user to choose the more appropriate one. Injury risk curves built for the WorldSID 50th side impact dummy with these different methods could vary significantly, depending on the sample considered (Petitjean et al. 2009). As a consequence, further investigations were needed to determine the fields of application of the different methods and to recommend the best statistical method depending on the biomechanical sample considered.
Technical Paper

Sensitivity of the WorldSID 50th and ES-2re Thoraces to Loading Configuration

2010-11-03
2010-22-0013
An ideal injury criterion should be predictive of the risk of injury across the range of loading conditions where it may be applied. The injury risk curve associated with this criterion should be applicable to all loading conditions. With respect to side impact, the injury risk curve should apply to pure lateral or oblique loading by rigid and padded walls, as well as airbags. Trosseille et al., (2009) reported that the number of fractured ribs was higher in pure lateral impact than in forward oblique interaction with an airbag. A good dummy criterion should be able to account for this difference. To evaluate various injury criteria with the WorldSID 50th and ES-2re dummies, the dummies were exposed to the same airbag loadings as the PMHS. The criteria measured in the dummy tests were paired with the rib fractures from the PMHS tests.
Technical Paper

Evaluation of Thoracic Deflection as an Injury Criterion for Side Impact Using a Finite Elements Thorax Model

2009-11-02
2009-22-0006
This study aims to investigate the relationship between the number of rib fractures and the thoracic deflection in side impact, and in particular its variability with respect to various loading configurations. The relevance of thoracic deflection as an injury criterion depends on the existence or not of this variability. Few studies were dedicated to this issue in the literature. First, a validation database was established, which covers different impact directions (frontal, lateral and oblique), different loading types (impactor, belt and airbag), and different injury levels (from the absence of, to presence of numerous ribs fractured). The HUMOS human body model was then modified and validated versus the database. Besides the typical validation in terms of global response, particular attention was paid to validate the model with respect to the ribcage strain profile, the occurrence of rib fractures and their locations.