Refine Your Search

Topic

Search Results

Viewing 1 to 19 of 19
Standard

Voltage Regulation and Limits

2022-12-16
CURRENT
J3226_202212
This document defines the test procedures and performance limits of steady state and transient voltage characteristics for 12 V, 24 V, or 48 V electrical power generating systems used in commercial ground vehicles.
Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design—Truck and Bus

2022-06-22
CURRENT
J2698_202206
This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids.
Standard

Circuit Breakers

2022-05-26
CURRENT
J553_202205
This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 200 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 VDC, 24 VDC, and 48 VDC electrical systems. Some circuit breakers may have dual voltage ratings (AC and DC); however, this document evaluates DC performance only.
Standard

Cable Marking for Circuit Identification in Multi-Voltage Power Distribution Systems

2021-01-13
CURRENT
J3176_202101
This SAE Standard establishes the minimum circuit identification and requirements for Multi-Voltage Power Distribution Systems (MVPDS) for use on trucks and buses. A Multi-Voltage Power Distribution System is one that distributes two or three voltages, up to 60 VDC, to power the controls, instruments, and devices.
Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design—Truck and Bus

2018-10-04
HISTORICAL
J2698_201810
This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids.
Standard

Electric Vehicle Power Transfer System Using a Three-Phase Capable Coupler

2018-04-25
HISTORICAL
J3068_201804
This document covers the general physical, electrical, functional, testing, and performance requirements for conductive power transfer to an Electric Vehicle using a Coupler capable of, but not limited to, transferring three-phase AC power. It defines a conductive power transfer method including the digital communication system. It also covers the functional and dimensional requirements for the Electric Vehicle Inlet, Supply Equipment Connector, and mating housings and contacts. Moveable charging equipment such as a service truck with charging facilities are within scope. Charging while moving (or in-route-charging) is not in scope.
Standard

Circuit Breakers

2016-07-12
HISTORICAL
J553_201607
This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 200 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 V and 24 V DC electrical systems. Some circuit breakers may have dual voltage ratings (AC and DC), however, this document evaluates DC performance only.
Standard

Auxiliary Power Unit Electrical Interface Requirements for Class Eight Trucks

2015-12-18
HISTORICAL
J2891_201512
This SAE Recommended Practice covers the design and application of a 120 VAC single phase engine based auxiliary power unit or GENSET. This document is intended to provide design direction for the single phase nominal 120 VAC as it interfaces within the truck architecture providing power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off.
Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design—Truck and Bus

2014-11-24
HISTORICAL
J2698_201411
This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids.
Standard

Heavy-Duty Circuit Breakers

2013-05-03
CURRENT
J1625_201305
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for circuit breakers in ratings from 50 to 200 A. The document covers externally mounted automatic reset and manually reset types of circuit breakers for low voltage DC operation (typically 50 V or less).
Standard

Auxiliary Power Unit Electrical Interface Requirements for Class Eight Trucks

2010-07-06
HISTORICAL
J2891_201007
This SAE Recommended Practice covers the design and application of a 120 VAC single phase engine based auxiliary power unit or GENSET. This document is intended to provide design direction for the single phase nominal 120 VAC as it interfaces within the truck architecture providing power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off.
Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design—Truck and Bus

2008-01-14
HISTORICAL
J2698_200801
This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids.
Standard

Circuit Breakers

2004-06-22
HISTORICAL
J553_200406
This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 50 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 V and 24 V DC electrical systems. Some circuit breakers may have dual voltage ratings (AC and DC), however, this document evaluates DC performance only.