Refine Your Search

Search Results

Viewing 1 to 20 of 20
Standard

Oxygen Mask Assembly, Demand and Pressure Breathing, Crew

2014-10-16
CURRENT
AS452B
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
Standard

Reducers, Oxygen Pressure

2012-07-24
CURRENT
AS17852A
This specification covers the requirements for two types of oxygen pressure reducers.
Standard

Continuous Flow Oxygen Systems

2002-10-21
CURRENT
AIR825/8
This SAE Aerospace Information Report (AIR) provides general information on Continuous Flow Oxygen Systems which are available, principle functions of those systems and technical approaches to be taken into account during design and realization of systems. However, particular performance specifications and detailed information of manufacturing, testing and integration of such systems is beyond the scope of this document.
Standard

Demand Oxygen Systems

2002-09-30
CURRENT
AIR825/9
This SAE Aerospace Information Report (AIR) describes the general operating principles of demand oxygen equipment, including variant types such as diluter-demand and pressure breathing equipment. The sources of oxygen supply that can be used in connection with a demand oxygen mask are in principle the same as those used for other oxygen dispensing devices. Except for mention of a few features specifically related to demand equipment, this document does not discuss oxygen sources in detail and the reader is advised to consult other applicable documents that describe the operation of oxygen sources for additional information.
Standard

Minimum Standards for Valve, High Pressure Oxygen, Cylinder Shut Off, Manually Operated

2002-03-01
CURRENT
AS1066B
This standard covers all types of manually operated high pressure oxygen, cylinder shut off valves for use in commercial aircraft. It is intended that the valve shall be attached to a pressure cylinder storing oxygen under a nominal pressure of 12.76 MPa (1850 psig) at 21 °C (70 °F). Upon opening the valve, oxygen will be permitted to discharge from the storage cylinder to the valve outlet and to other downstream components of the oxygen system. It shall also be possible to recharge the cylinder through the valve.
Standard

Minimum Standard for Portable Gaseous, Oxygen Equipment

2000-03-01
HISTORICAL
AS1046B
This standard is intended to apply to that portable compressed gaseous oxygen equipment used for the administration of supplementary and/or first aid oxygen to one or more occupants of either private or commercial transport aircraft. This standard is applicable to the following types of portable oxygen equipment: a Continuous flow; b Demand flow; 1 Straight demand 2 Diluter demand 3 Pressure demand c Combination continuous flow and demand flow.
Standard

Reducers, Oxygen Pressure

1999-07-01
HISTORICAL
AS17852
This specification covers the requirements for two types of oxygen pressure reducers.
Standard

Transfilling and Maintenance of Oxygen Cylinders

1998-12-01
HISTORICAL
AIR1059B
The purpose of this document is to list the best available information and guidelines for the qualification of personnel who are responsible for the filling of fixed or portable aircraft oxygen cylinders.
Standard

Oxygen System Fill/Check Valve

1997-12-01
CURRENT
AS1225A
This SAE Aerospace Standard (AS) defines minimum standards of design, construction, and performance for two types of permanently installed, high pressure 12,800 kPa (1850 psig) and 13,800 kPa (2000 psig) oxygen system cylinder fill valves used in commercial aircraft. Refer to Purchaser's Specification for Requirements which are beyond the scope or level of detail provided in this document. One valve has an adjustable pressure sensitive closing valve to automatically control the final pressure for a correct amount of oxygen in the system. The second valve incorporates an automatic shutoff feature designed to limit system overpressurization in the event maintenance personnel do not stop system filling at the correct pressure. The intent of the fill valves is to control the rate of fill to limit the rise in temperature caused by compression heating to acceptable values, prevent oxygen back flow and prevent the ingestion of foreign matter that could cause contamination of the system.
Standard

Minimum Standards for Valve, High Pressure Oxygen, Line Shut Off, Manually Operated

1996-07-01
HISTORICAL
AS1214A
This standard covers all types of manually operated high pressure oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft. It is intended that the line valve should be installed in a position accessible in flight, when the cylinder mounted oxygen valves are not. The line shutoff valve may also be used optionally in large systems as a maintenance aid where only a portion of the system need be opened up and purged after repair or replacement of one or more parts.
Standard

MINIMUM STANDARDS FOR VALVE, HIGH PRESSURE OXYGEN, CYLINDER SHUT OFF, MANUALLY OPERATED

1996-07-01
HISTORICAL
AS1066A
This standard covers all types of manually operated high pressure oxygen, cylinder shut off valves for use in commercial type aircraft. It is intended that the valve shall be attached to a pressure cylinder storing oxygen under pressure of 1800 to 2100 psig at 70 °F. Upon opening the valve, oxygen will be permitted to discharge from the storage cylinder to the valve outlet and thence to other components of the oxygen system. It shall also be possible to recharge the cylinder through the valve.
Standard

Crewmember Demand Oxygen Mask For Transport Category Aircraft

1996-07-01
CURRENT
AS8026A
This standard covers oxygen masks and breathing valves used with both panel mounted and mask mounted demand and pressure-demand oxygen regulators. Mask mounted oxygen regulators are covered under other standards, but when the mask mounted regulator incorporates an integral exhalation valve, the performance of this valve shall meet the requirements of this standard.
Standard

MINIMUM STANDARD FOR PORTABLE GASEOUS, OXYGEN EQUIPMENT

1976-02-01
HISTORICAL
AS1046A
This standard is intended to apply to that portable compressed gaseous oxygen equipment used for the administration of supplementary and/or first aid oxygen to one or more occupants of either private or commercial transport aircraft.
Standard

HIGH PRESSURE OXYGEN SYSTEM FILLER VALVE

1971-07-30
HISTORICAL
AS1225
This AS covers oxygen filler valves for use in aircraft to ensure safe servicing of high pressure oxygen system cylinders. The intent is that the valve shall automatically control the rate of fill such that the temperature rise in the oxygen system caused by compression heating of the gas will be within acceptable limits. In addition, the valve shall have a pressure sensitive closing valve to automatically control the final pressure for a correct amount of oxygen in the system cylinder. The pressure closing level may be manually selected by means of adjustment dials on the valve.
Standard

MINIMUM STANDARDS FOR VALVE, HIGH PRESSURE OXYGEN, LINE SHUT OFF, MANUALLY OPERATED

1971-07-01
HISTORICAL
AS1214
This standard covers all types of manually operated high pressure oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft. It is intended that the line valve should be installed in a position accessible in flight, when the cylinder mounted oxygen valves are not. The line shutoff valve may also be used optionally in large systems as a maintenance aid where only a portion of the system need be opened up and purged after repair or replacement of one or more parts.
Standard

DYNAMIC TESTING SYSTEM FOR OXYGEN BREATHING EQUIPMENT

1969-04-01
HISTORICAL
ARP1109
This ARP covers a system and method to be used, at all appropriate altitudes, in testing of breathing oxygen systems consisting of demand regulator, connecting hose, and mask, or regulator and helmet systems, or individual components.
Standard

MINIMUM STANDARDS FOR VALVE, HIGH PRESSURE OXYGEN, CYLINDER SHUT OFF, MANUALLY OPERATED

1968-12-01
HISTORICAL
AS1066
This standard covers all types of manually operated high pressure oxygen, cylinder shut off valves for use in commercial type aircraft. It is intended that the valve shall be attached to a pressure cylinder storing oxygen under pressure of 1800 to 2100 psig at 70 F. Upon opening the valve, oxygen will be permitted to discharge from the storage cylinder to the valve outlet and thence to other components of the oxygen system. It shall also be possible to recharge the cylinder through the valve.
Standard

Oxygen Mask Assembly, Demand and Pressure Breathing, Crew

1965-10-01
HISTORICAL
AS452A
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand