Wire, Electrical, Crosslinked Polyalkene, Crosslinked Alkane-Imide Polymer, Or Polyarlyene Insulated, Copper Or Copper Alloy

2019-07-08
CURRENT
AS81044B
AS81044 covers single conductor electric wires made as specified in the applicable detail specification with tin-coated, silver-coated, or nickel-coated copper or copper alloy conductors insulated with crosslinked polyalkene, crosslinked alkane imide polymer, or polyarylene. The crosslinked polyalkene, crosslinked alkane-imide polymer, or polyarylene may be used alone or in combination with other insulation materials as specified in the detail specification.
Standard

Cable, Power, Electrical, Portable General Specification For

2019-06-07
CURRENT
AS5756B
This specification covers 600 V heavy duty, portable, power, single and multiconductor, electrical cable for severe flexing service (see detail specifications for voltage limitations). The AS5756 insulation system has been used in aerospace ground power applications using 115/200 V (phase to neutral) at 400 Hz AC. Verification of the suitability of this product for use in other electrical system configurations (600 V, etc.) is the responsibility of the user.
Standard

Insulation Sleeving, Electrical, Heat Shrinkable, General Specification for

2019-04-08
CURRENT
AS23053A
This specification establishes the requirements for various types and colors of electrical insulating sleeving that will shrink to a predetermined size upon the application of heat. This specification includes provisions for demonstrating compliance with qualification requirements (see Section 4 and 7.3), in process inspection, and statistical process control inspections (see 4.4). The continuous operating temperature ranges for the sleeving classes covered by this specification are from -112 to +482 °F (-80 to +250 °C). The continuous operating temperature range for each sleeving class is given in the applicable detail specification.
Standard

Cable, Thermocouple Extension, Shielded and Unshielded

2018-10-17
WIP
AS5419A
This SAE Aeorrspace Standard (AS) covers the requirements for thermocouple extension cable. Manufacturers of primary thermocouple wire in accordance with this specification must be qualified to the similar wire type specified in Table 1.
Standard

Wire, Electric, Polyvinyl Chloride Insulated, Copper or Copper Alloy

2018-10-15
CURRENT
AS50861B
This specification covers polyvinyl chloride insulated single conductor electric wires made with tin-coated copper conductors or silver-coated copper alloy conductors. The polyvinyl chloride insulation of these wires may be used alone or in combination with other insulating or protective materials.
Standard

Verification of New Conductor Alloys for AS29606 Conductors Qualification

2017-11-15
CURRENT
AS6324
AS6324 specifies the requirements for comparative testing of new copper and copper alloy conductors to AS29606 qualified conductors. AS29606 approved conductors are used for the construction of insulated wire defined in SAE Aerospace wire standards (i.e., AS22759, AS81044, etc.). AS6324 defines testing which meets or exceeds the minimum test requirements of AS29606 and AS22759 and its detailed specification sheets.
Standard

Cable, Electric, Filter Line, Radio Frequency Absorptive

2017-11-08
CURRENT
AS85485B
This specification covers the requirements for radio frequency absorptive component wires and finished cables which function electrically as distributed low-pass filters. Materials and construction details are specified in the detail specification.
Standard

Insulation Sleeving, Electrical, Heat Shrinkable, General Specification For

2016-10-16
HISTORICAL
AS23053
This specification establishes the requirements for various types and colors of electrical insulating sleeving that will shrink to a predetermined size upon the application of heat. This specification includes provisions for demonstrating compliance with qualification requirements (see Section 4 and 7.3), in process inspection, and statistical process control inspections (see 4.4). The continuous operating temperature ranges for the sleeving classes covered by this specification are from -112 to +482 °F (-80 to +250 °C). The continuous operating temperature range for each sleeving class is given in the applicable detail specification.
Standard

Sleeve, Protection, For Cable and Harness Protection

2015-12-02
CURRENT
AS60491
Procurement specification is principally for defining protection sleeves on a cable or group of electrical/fiber optic wires (wiring bundle). Single wire protection depends on the minimum diameter of the wire. Sleeve may be used to protect a wire bundle for a platform installation or for repair of installed damaged jacket or jacket/shielded wire bundles. See AS50881 for aerospace wire bundle protection installations.
Standard

Test Methods for Insulated Electric Wire

2012-02-03
CURRENT
AS4373E
This standard describes test methods for insulated, single conductor, electric wire intended for aerospace applications. Particular requirements for the wire being tested need to be specified in a procurement document or other detail specification. Suggested minimum requirements are included in the notes at the end of some of the test methods. SAE Performance Standard AS4372 uses some of the tests in this document for evaluating comparative performance of aerospace wires.
Standard

Wire, Electrical, Crosslinked Polyalkene, Crosslinked Alkane-Imide Polymer, or Polyarlyene Insulated, Copper or Copper Alloy

2011-08-11
HISTORICAL
AS81044A
This specification covers single conductor electric wires made as specified in the applicable specification sheet with tin-coated, silver-coated, or nickel-coated copper or copper alloy conductors insulated with crosslinked polyalkene, crosslinked alkane-imide polymer, or polyarylene. The crosslinked polyalkene, crosslinked alkane-imide polymer, or polyarylene may be used alone or in combination with other insulation materials as specified in the specification sheet.
Standard

Wire, Electrical, Solderless Wrap, Insulated and Uninsulated, General Specification For

2011-07-18
CURRENT
AS81822A
This specification covers both insulated and uninsulated solid conductor wire, designed for solderless wrap connections in electrical and electronic devices and equipment. The terminations of the wire are intended to be made with hand or automatic tools which wrap the wire, under tension, around terminal pins (commonly called wrapposts) to form solderless wrapped connections.
Standard

Investigation of Silver Plated Conductor Corrosion (Red Plague)

2011-06-20
CURRENT
AIR4487A
This SAE Aerospace Information Report (AIR) shall be limited to information about cuprous/cupric oxide corrosion of silver plated conductors. It examines some possible causes and some recommendations to minimize the possibility of its occurrence. It also provides a number of reference documents that describe the corrosion in detail, methods to determine conductor damage, methods to produce the corrosion, and other investigative reports of this phenomena and their conclusions.
Standard

Cable, Electric, Filter Line, Radio Frequency Absorptive

2011-02-14
HISTORICAL
AS85485A
This specification covers the requirements for radio frequency absorptive component wires and finished cables which function electrically as distributed low-pass filters. Materials and construction details are specified in the detail specification.
Standard

Wire, Electric, Polyvinyl Chloride Insulated, Copper or Copper Alloy

2011-01-14
HISTORICAL
AS50861A
This specification covers polyvinyl chloride insulated single conductor electric wires made with tincoated copper conductors or silver-coated copper alloy conductors as specified in the applicable detail specification. The polyvinyl chloride insulation of these wires may be used alone or in combination with other insulating or protective materials.