Refine Your Search

Search Results

Technical Paper

A Study on the Application of the Two–Color Method to the Measurement of Flame Temperature and Soot Concentration in Diesel Engines

1980-09-01
800970
Flame temperature and KL factor in a DI diesel engine are measured optically by the two-color method. Some differences are observed between the measure values at visible and infrared wavelengths. These differences are caused by: (1) effect of change of index α in time at infrared wavelength during combustion period; (2) effect of distributions of temperature and soot concentration along optical path; and (3) effect of reflection at the walls. The optical characteristics and some other problems on the instrumentation of the two-color method at both wavelengths are also discussed.
X