Technical Paper

Heat Transfer From Impinging Diesel Flames to the Combustion Chamber Wall

1997-02-24
970896
The local heat fluxes from impinging combusting and evaporating diesel sprays to the wall of a square combustion chamber were measured in a rapid compression machine. It was revealed that the ratio of local heat flux between the combusting and evaporating spray, q̇c/q̇e, is of the same order of magnitude as (Tc-Tw)/(Te-Tw) and its values estimated by a two-zone model agree roughly with the measured ones. The time-mean local heat flux during the spray impingement was found to be approximately proportional to the 0.8th power of the injection velocity and the heat-transfer phenomenon depends largely on whether the ignition starts before or after the impingement.
Technical Paper

Effects of Flame Motion and Temperature on Local Wall Heat Transfer in a Rapid Compression-Expansion Machine Simulating Diesel Combustion

1992-10-01
922208
Local heat flux from the flame to the combustion chamber wall, q̇, was measured the wall surfaces of a rapid compression-expansion machine which can simulate diesel combustion. Temperature of the flame zone, T1, was calculated by a thermodynamic two-zone model using measured values of cylinder pressure and flame volume. A local heat transfer coefficient was proposed which is defined as q̇/(T1-Tw). Experiments showed that the local heat transfer coefficient depends slightly on the temperature difference, T1-Tw, but depends significantly on the velocity of the flame which contacts the wall surface.